Customization: | Available |
---|---|
After-sales Service: | Lifetime Technical Support, Online Service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1) Turn ratio detection
2) Ratio and angle error check
3) Polarity test
4) Excitation characteristic test
5) Secondary winding resistance measurement and secondary burden measurement
6) 5% and 10% error curve measurement
7) Transient characteristics analysis
8) Automatic nameplate inference
9) Knee point voltage/current
10) Accuracy Limit Factor (ALF)
11) Instrument security factor (FS)
12) Secondary time constant (Ts)
13) Remanence coefficient (Kr)
14) Accuracy
15) Saturation and desaturation inductance
16) Knee point electromotive force
17) Limit electromotive force
18) Area factor
19) Iron core analysis and core hysteresis loop measurement
Technical Index for GDVA-405 0.02% Class Automatic CT PT Analyzer for 500kV Current transformer testing
Voltage output | 0.1-180V (AC) |
Current output | 0.001-5A(RMS) |
Power output | 500VA |
Max. knee voltage measurement | 60KV |
Current measurement | range: 0-10A (automatically change range in 0.1/0.4/2/10A) error: <±0.1%+0.01%FS |
Voltage measurement | range: 0-200V (automatically change range in 1V/10V/70V/200V). error: < ±0.1%+0.01%FS |
Turns ratio measurement Range | 1~35000 1~2000, error<0.05% 2000~5000,error<0.1% 5000~35000,error<0.2% |
Phase measurement | error:±2min resolution: 0.01min |
Winding resistance measurement | range:0-8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm) error: < 0.2%RDG+0.02%FS Maximum resolution : 0.1mΩ |
CT Secondary burden | range: 0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) error:<0.2%RDG+0.02%FS Maximum resolution : 0.001ohm |
PT Secondary burden | range: 0-80kohm (automatically change range in 800ohm/8kohm/80kohm) error: <0.2%RDG+0.02%FS Maximum resolution : 0.1ohm |
PT ratio measurement |
1-35000, 1-10000 error<0.1%, 10000-35000 error<0.2% |
PC Control | Optional |