0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support, Online Service
Warranty: 1 Year
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • 0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing
  • 0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing
  • 0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing
  • 0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing
Find Similar Products
  • Overview
  • Product Parameters
Overview

Basic Info.

Model NO.
GDVA-405
Test Standards
IEC60044-1/2/5/6, IEC61869, C57.13
Accuracy
0.02%(Typical), 0.1%(Guarantee)
Application
Routine Testing of CT PT
CT Types
M, P, Tpy, Bushing CT, Gis CT.etc
Voltage Output
0.1-180V (AC)
Current Output
0.001-5A(RMS)
PC Control
Yes(Optional)
Transport Package
Plywood Case for Gdva-405 CT PT Analyzer
Specification
39KG with packages for GDVA-405 CT PT Analyzer
Trademark
CHONGQING GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

0.02% Class Automatic CT PT Analyzer for 500kV Current transformer testing

The volt ampere characteristic (also known as excitation characteristic) of a current transformer is one of the most important handover tests. It is also listed as a necessary test item in accordance with the requirements of the GB50150-2016 national standard, along with the transformation ratio, angle error, 10% error test, primary and secondary winding DC resistance, and power frequency withstand voltage test of the current transformer.

0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing
Main Test Items for current transformer(CT):


1) Turn ratio detection

2) Ratio and angle error check

3) Polarity test

4) Excitation characteristic test

5) Secondary winding resistance measurement and secondary burden measurement

6) 5% and 10% error curve measurement

7) Transient characteristics analysis

8) Automatic nameplate inference

9) Knee point voltage/current

10) Accuracy Limit Factor (ALF)

11) Instrument security factor (FS)

12) Secondary time constant (Ts)

13) Remanence coefficient (Kr)

14) Accuracy

15) Saturation and desaturation inductance

16) Knee point electromotive force

17) Limit electromotive force

18) Area factor

19) Iron core analysis and core hysteresis loop measurement

 
Product Parameters

Technical Index for GDVA-405 0.02% Class Automatic CT PT Analyzer for 500kV Current transformer testing

 
Voltage output 0.1-180V (AC)
Current output 0.001-5A(RMS)
Power output 500VA
Max.  knee voltage measurement 60KV
Current measurement range: 0-10A (automatically change  range in 0.1/0.4/2/10A)
error:  
<±0.1%+0.01%FS
Voltage measurement range: 0-200V (automatically change range in 1V/10V/70V/200V).
error: < ±0.1%+0.01%FS
Turns ratio measurement Range 1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
 
Phase measurement   error:±2min
resolution: 0.01min
Winding resistance measurement range:0-8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
error: < 0.2%RDG+0.02%FS
Maximum resolution :  0.1mΩ
CT Secondary burden range: 0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
error:<0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
PT Secondary burden range: 0-80kohm (automatically change range in 800ohm/8kohm/80kohm)
error: <0.2%RDG+0.02%FS

Maximum resolution : 0.1ohm
PT ratio measurement

1-35000,

1-10000 error<0.1%, 

10000-35000 error<0.2%
PT ratio error measurement :Typical error<0.05%,  Maximum Error<0.1%
PT phase angle measurement maximum error < 3min

PC Control Optional


0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing
0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing0.02% Class Automatic CT PT Analyzer for 500kv Current Transformer Testing