Automated Pensky-Martens Closed-Cup Apparatus for ASTM D93 Flash Point Test
Contact Supplier
Product Highlights
- Compliance with Standards: Designed per ASTM D93 and GB/T 261-2008 for accurate flash point testing.
- Automated Operation: Features automatic lid lifting, ignition, detection, and data printing.
- LCD Interface: Full English man-machine dialog with menu prompts and guide-type input.
- Data Connectivity: Equipped with RS-232/485 ports to save 100 groups of historical data.
- Atmospheric Correction: Automatically corrects atmospheric pressure influence and calculates corrections.
- Lifetime Maintenance: Products are lifetime maintained with a 18-month guarantee period.
- Stainless Steel Build: Constructed with durable stainless steel material for lab durability.
Product Attributes
- Customization
- Available
- After-sales Service
- 2 Years
- Warranty
- 2 Years
- Model NO.
- GD-261D
- Customized
- Non-Customized
- Structure
- Desktop
- Material
- Stainless Steel
- Certification
- ISO
- Application
- School, Lab
- Type
- Measurement Type
- Pensky Martens Flash Point
- Pensky-Martens Closed-Cup Flash Point Apparatus
- Overseas Warranty
- 2 Years
- Closed Cup Flash Point Tester
- ASTM D93 Close Cup Flash Point Apparatus
- Pensky Martens Closed Cup Test
- Pensky-Martens Closed Cup Flash Point Apparatus
- Feature
- Equipped with Standard RS-323,485 Computer Port
- OEM Service
- Available
- Reference Standard
- ASTM D93
- ASTM D 93
- ASTM D93 Pmcc Flash Point Meter
- Test Method
- Pensky-Martens Closed Cup
- Display
- LCD Display
- Transport Package
- Venner Case
- Specification
- ISO Certificate
- Trademark
- GOLD
- Origin
- China of Chongqing
- HS Code
- 9031809090
- Production Capacity
- 200PCS/Month
Product Images of Automated Pensky-Martens Closed-Cup Apparatus for ASTM D93 Flash Point Test
Find Similar Products
Product Description
This Automated Pensky-Martens Closed-Cup Apparatus is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. The Pensky Marten Flash Point Apparatus is used to make determination of the closed cup flash point of the petroleum products.

(1) Gas input (2) Communication port (3) Power socket (4) Stirring rate adjustment of procedure B (5)Stirring rate adjustment of procedure ANote 1:The lifting arm moves automactically. It is not allowed to be pulled up and down manually.
Note 2:The flash point detector must be kept clean.Or the sensitivity will be reduced.
1. The Automated Pensky-Martens Closed-Cup Apparatus adopts LCD screen to display. Full English man-machine dialog interface. It can preset the parameters of expected flash point,sample mark number, atmospheric pressure, test date,etc.It has menu to prompt and input function of guide type.
2. The Automated Pensky-Martens Closed-Cup Apparatus adopts simulation tracking display the function curve of temperature rising and test time.It has prompt functions of English mis-operation,test date and test time.
3. It is equipped with standard RS-323,485 computer port.The lower computer can save 100 groups of historical data. The test data can be saved for a long time, transmitted and modified if the instrument being connected with computer.
4. It can correct the influence of atmospheric pressure and calculate the correction automatically.
5. Differential detection.Automatically correct the systematic deviation.
6. Automatically open the lid,fire,detect and print test data.The test arm lifting up and down automatically.
7. The pensky martens closed cup tester adopts electric ignition to fire light the gas flame.It will light only need to press the button.
8. Humanized design,beautiful and safe. Easy to operate.
| Item | Breakdowns | Solutions | Remarks |
| 1 | The LCD screen shows nothing after power on. | 1. Check the connection of power line . 2. Open the side plate of instrument to check whether there exist looseness of plugs. |
|
| 2 | The repeatability errors of determinations are big. | 1. Check whether the test environment can meet the requirements. 2. Check the showing temperature of screen and recalibrate when needed. 3. Clean the oil dirt on the deteting ring to keep the detecting sensitivity. |
|
| 3 | 1) No heating 2) Can not fire the igniting mouth. |
1. Check the heating furnace.Replace it if being broken. 2. Check the gas circuit to make sure there is no stoppage and gas source be adjusted well. |
|
| 4 | The test arm cannot rise up or lower down. | Check whether the screw of electric machine and test arm is dropped. |
| Power supply | AC(220±10%)V,50Hz |
| Flash point determination | Range: Ambient to 300ºC |
| Accuracy | 0.1ºC |
| Stirring rate | Procedure A: (90~120)RPM, Procedure B: (250±10)RPM; Automatic control and manually adjustable. |
| Igniting mode | Electric ignition |
| Maximum power consumption | 500W |
| Working condition | Ambient temperature:(10~40)ºC |
| Dimension | 520mm*360mm*310mm |
Automated Pensky-Martens Closed-Cup Apparatus for ASTM D93 Flash Point Test

| Pre-sales consulting | We promise to provide you professional consulting for any of your laboratory needs. We will help you select the most suitable instruments according to your requirement. We also offer free sample testing service before you placing order. |
| Order processing | We promise a rapid delivery time to you after we receive your order to make sure the instruments can be delivered to your laboratory at the fastest. You can contact us at any time to get an update of your production and logistics information. |
| After-sales service | We promise to give you a prompt response(with 24 hours) to any questions. We provide you a free training in our factory. We also provide chargeable onsite training according to your order value. The guarantee period of our products is 18 months. All of our products are lifetime maintained. |
If you are interested in our Automated Pensky-Martens Closed-Cup Apparatus for ASTM D93 Flash Point Test product or have any questions, please feel free to contact us.
About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR229508". Items marked "" are certified.
Company Profile
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd is a high-tech enterprise for researching, designing, developing and producing scientific and measuring instruments. With its continuous drawing of lessonas, unremitting innovation and borrowing of advanced technology from both at home and abroad, our company is now becoming a professional manufacture of oil tester, electric tester, fire testing equipment, and oil purifier.
Though highly acclaimed and favorably accepted by numerous customers and possessed of the right to import and export, to ensure the high quality of our products, we conduct our manufacturing in strict accordance with various standards of ISO, ASTM D, IP, GB etc. We have developed sales channels in many countries and regions such as Thailand, Philippine, Iran, Indonesia, Spain, Iceland, Chile, Regions of Southeast Asia, Middle East, Europe, North and South America etc, and have gained strong advantage and high reputation in international market.
We have persisted on the business idea of "Integrity Basis and Quality First" for the stable and constant development. We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity. Client, quality and service are our supreme target!
About Our Factory & Business Background
- Address
- #2501, China Resources Building, Xiejiawan, Jiulongpo District, Chongqing, 400050, China
- Terms of Payment
- LC, T/T, PayPal, Western Union
- International Commercial Terms(Incoterms)
- FOB, EXW, CFR, CIF, DDP, CPT
- Average Lead Time
-
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays - Nearest Port
- Chongqing, Shanghai
Our Production Capability & Technical Expertise
Our Industry Experience & Global Business Record
- Export Year
- 2008-05-03
- Main Markets
- North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
FAQ
- What standards does this apparatus comply with?
- It is designed and manufactured according to ASTM D93 and GB/T 261-2008 standards.
- Is the device customizable?
- No, this product is Non-Customized.
- What is the warranty period?
- The guarantee period is 18 months, and we provide lifetime maintenance for all products.
- How is the data stored and transmitted?
- It features RS-232/485 computer ports to save 100 groups of historical data and transmit data when connected to a computer.
- Does it automatically correct for atmospheric pressure?
- Yes, it can automatically correct the influence of atmospheric pressure and calculate the correction.
- What after-sales services are provided?
- We offer pre-sales consulting, free sample testing, rapid delivery, 24-hour response, free factory training, and chargeable onsite training.
Send your message to this supplier
People who viewed this also viewed
-
US$1,499.00-1,600.00 / Piece
-
US$800.00-1,000.00 / Piece
-
US$1.00 / Piece
-
US$8,500.00-15,000.00 / Piece
-
US$900.00-1,600.00 / Piece
-
US$550.00-1,250.00 / Piece
-
US$3,900.00-4,800.00 / Piece
-
US$800.00-1,800.00 / Piece
-
US$53,000.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Oil Testing Equipment
- Closed Cup Flash Point Tester
- Automated Pensky-Martens Closed-Cup Apparatus for ASTM D93 Flash Point Test
Related Categories
Hot Searches
- Instrument Apparatus Factories
- Test Point Factories
- Battery Tester Factories
- China Tester Factories
- Flash Point Tester
- China Martens
- Pensky Martens
- Automatic Flash Point Tester
- Open Flash Point Tester
- Pmcc Bulkbuy