• Automatic X-ray Fluorescence Sulfur-in-Oil Analyzer for Sulfur Analysis From Crude to Fuel
  • Automatic X-ray Fluorescence Sulfur-in-Oil Analyzer for Sulfur Analysis From Crude to Fuel
  • Automatic X-ray Fluorescence Sulfur-in-Oil Analyzer for Sulfur Analysis From Crude to Fuel
  • Automatic X-ray Fluorescence Sulfur-in-Oil Analyzer for Sulfur Analysis From Crude to Fuel

Automatic X-ray Fluorescence Sulfur-in-Oil Analyzer for Sulfur Analysis From Crude to Fuel

After-sales Service: Online Service and Offline Service
Warranty: 2 Years
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Universal Testing Machine
Maxcapacity: <1000KN
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-4294
Accuracy Grade
0.5
Weight
0-100Kg
Power Source
AC220V
Sulfur Analyzer
X-ray Fluorescence Oil Sulfur Analyzer
Total Sulfur Analyzer
Sulfur in Fuel Analysis to ASTM D4294, ISO8754
Total Sulfur Analysis
Sulfur Analysis From Crude to Fuel
Measurement Range
10ppm to 5%
Detection Limit
10 Ppm
Test Samples
Distillates, Diesel, Heavies, Crude and Marine Fue
Measurement Time
It Can Be Set to 30s or 60s or 90s or 120s or 150s
Calibration Curve Numbers
It Can Save 10 Calibration Curves
Touch Screen
8-Inch (1024*768)Capacitive Touch Screen
Communication Port
RS232 Serial Port
Transport Package
Wooden Case or as Required
Specification
Refer to ASTM D4294 and ISO 8754
Trademark
GOLD
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
100sets/Month

Product Description

GD-4294 Automatic X-Ray Fluorescence Sulfur-in-Oil Analyzer for Sulfur Analysis from Crude to Fuel


Background: 

The need for sulfur analysis permeates almost every aspect of the petroleum industry, from upgrading and refining through to transportation and retail. 

The XRF Sulfur in Oil Analyzer can analyze a wide range of fuel, from Crude heavy oil to light oil.

The X-Ray Fluorescence Sulfur-in-Oil Analyzer can be widely applied to petroleum and petroleum products such as diesel fuel, jet fuel, kerosene, other distillate oil, naphtha, residual oil, lubricating base oil, hydraulic oil, crude oil, unleaded gasoline, gasoline-ethanol blends, and biodiesel. 


Key Features:

(1) With electrical, mechanical and microprocessor integration design, so it is compact and beautiful;

(2) It can determine various products and in a wide measurement range. It is rapid for analysis and it only need little standard sample.

(3) Adopts fluorescence intensity ratio analysis methods, it can make correction to temperature and pressure automatically and it can also make correction to ratio of carbon and hydrogen (C/H).

(4) 8-inch (1024*768)capacitive touch screen. 

(5) The EDXRF Sulfur Analyzer can determine its working state and electric parameters by making repeatability test and spectrum scan using reference samples.

(6) Equipped with a RS232 serial port, it can connect with any computer .

(7) It takes disposable sample cell with Mylar film, so it can avoid cross contamination. Sample cell is made by a multifunction pressure shaping device, so it is rapid and convenient. There is a hole on the sample cell cover and you can record sample serial number, S% (m/m), and date on the sample cell cover.

(8) The sample holder is installed on a slide rail,It is convenient and it can avoid any contamination to detection system.

(9) The EDXRF Sulfur Analyzer can save large quantity of test data. You can browse test data and calibration curves at any time.

(10) The sulfur analyzer uses a thermal printer, so it is easy to replace printing paper.

(11) Tightly protection measures to avoid oil leakage. The sample cell is placed on the leakage protection device. The sample cell can enter into the detection system together with the leakage protection device only during sample analysis procedures. If the instrument is not at sample analysis state, the leakage protection device will move out, so this can avoid any contamination to the detection system.

(12) Its safe X-ray protection measures can keep people from injury of X-ray radiation. 


Main Parameters:
 
1 Measurement range 20 ppm to 5%
2 Repeatability (r) <0.02894(S+0.1691)
3 Reproducibility (R) <0.1215(S+0.05555)
4 Detection limit 10 ppm
5 Oil sample quantity 3 ml (it is equal to sample depth of 3 mm~4 mm)
6 Measurement time it can be set to 30s or 60s or 90s or 120s or 150s
7 It can make determination automatically for single sample. Replication times can set 1,2, 3, 5, 10 at random; it will show average value and standard deviation at end of measurement.
8 Calibration curve numbers it can save 10 calibration curves
9 Working condition

a. Ambient temperature: 5~30ºC

b. Relative humidity: ≤85% (30 ºC)

10 Power supply AC 220V±20V, 50 Hz/60Hz; Rated power: 50 W
11 Size and weight 460mm*260mm*260mm, 12 kg


ASTM D4294 EDXRF Sulfur Analyzer 

Automatic X-ray Fluorescence Sulfur-in-Oil Analyzer for Sulfur Analysis From Crude to Fuel





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters