• Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test
  • Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test
  • Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test
  • Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test

Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for CT Temperature Rise Tester
Type: Current Transformers Temperature Rise Tester
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 4000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDCW
Display
Digital
Control
Manual Control
Power Source
AC220V
Device Name
Current Transformers Temperature Rise Tester
Current Booster Output Capacity
50kVA
DC Resistance Measurement Range
0~200 Ohm
Time Measurement and Recording Error
0.1ms
Current Control Error
0.5% of The Set Value
Primary Current Measurement Error
0.5% Reading Value +5D
Maximum Output Current
0~5000A (Greater Output Current Is Customizable)
Temperature Range
0~200 Degree
Transport Package
Wooden Case
Specification
ask the salesman
Trademark
GOLD
Origin
Chongqing, China
Production Capacity
200sets/Month

Product Description


Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test

Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test
 
Temperature Rise Test of Transformer
 
Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test

The temperature rise test is a crucial component of any comprehensive type test conducted on an oil-filled transformer. This test assesses whether the temperature increase within the transformer winding and oil remains within the specified limits set by the manufacturer.

 
Why Does A Transformer Get Hotter Than Usual?

Different losses that cause a transformer to get hot, in normal conditions, are losses due to resistance of the windings, Hysteresis, and eddy current losses.But, in some cases, the transformer gets hotter than usual.There are other main reasons why the transformer gets hotter.
 
  1. When the load exceeds the transformer rating "overloading the transformer".
  2. Higher ambient temperature.
  3. High moisture in the transformer oil increases the temperature rise because the transformer oil's ability to dissipate heat decreases.
  4. Blocked ventilation openings of transformers, sometimes by bird nests.
  5. When connecting loads with poor Power Factor.
  6. The misaligned or broken cooling fan of the transformer.
  7. Any issues with the transformer cooling system i.e. air fans or oil pumps?
  8. Any internal fault can increase the temperature of the transformer.
Functionalities of the Transformer Temperature Rise Tester
Adopts electronic voltage regulation to automatically adjust the output current size, and in the test process automatically control the output current value so that it is in the whole test process and the target test current error control within 0.5%.
Automatically switch the load value connected to the secondary circuit of the current transformer.
Measure the resistance of the secondary coil of the current transformer and calculate the maximum temperature rise of the current transformer coil based on the coil resistance and the initial temperature before the test.
Automatically monitors the temperature of the current transformer body and winding joints during the test and automatically determines whether the current transformer has reached temperature stability according to the selected criteria.
Record the temperature data change curve of all monitoring points during the whole test process, and record all the resistance values measured during the test process.
Automatically generate a standardised test report.
 
Specimen installation

Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test
Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test
Automated Temperature Rise Testing System for Current Transformers Temperature Rise Test

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters