Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Load and No-Load Capacity T
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment
  • Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment
  • Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment
  • Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment
  • Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment
  • Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment
Find Similar Products
  • Overview
  • Features:
  • Test Items:
  • Main Technical Parameters
  • Photo Show:
Overview

Basic Info.

Model NO.
GDBR-P
Type
Transformer Load and No-Load Capacity Tester
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
8kg
Power Source
AC220V
Product Name
Transformer Load and No-Load Capacity Tester
Test Standard
IEC60076
Power
Electronic
Test Item
Transformer
Current Measurement Range
100mA-60A
Accuracy
Class 0.2
Voltage Measurement Range
10V-650V
Percentage of No-Load Loss and No-Load C
Po,Io%
RMS of Three Phase Current
Ia,Ib,IC.
Average Value of Three Phase AC Voltage
Uab,Ubc,Uca
Transport Package
Wooden Case with Foam to Protect
Specification
350*300*200mm
Trademark
GOLD
Origin
Chongqing, China (Mainland)
HS Code
9031809090
Production Capacity
100 Set/Sets Per Month

Product Description

Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment

Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment
Features:
  • Measure transformer No-load current, No-load loss, short circuit voltage, short circuit loss and capacity.

  • Three meters testing methods.

  • When making three phase transformer No-load, load test, the instrument will judge if the wiring is correct automatically, and shows three phase voltage, current vector diagram.

  • Finish load test under 1600kVA below distribution transformer full current for single machine. Finish 2500kVA below distribution transformer load test under 1/3 rated current (Under 1/3 rated current, the instrument can be converted to load loss parameters under rated current.)

  • All test results are corrected automatically. The instrument automatic correction as follows, waveform correction, temperature correction, Non rated voltage correction and non rated current correction. The test results are more accurate.

  • 320*240 high brightness LCD screen, with brightness adjustment. Touch buttons make the operation more convenient.

  • Real-time clock, recording test date automatically, suitable for storage and management of test results.

  • Built-in panel-type thermal printer, fast print test results.

  • Power down store and browse data (test object set, measurement results, test time) functions. Store up to 500groups test results, data transmission online to PC.

  • Allows extended range measurement for external voltage transformer and current transformer. Measure test object of any parameters.
     

    Test Items:

     

    Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment

    RMS of three phase voltage: Uab,Ubc,Uca.

    Average value of three phase AC voltage: Uab,Ubc,Uca.

    RMS of three phase current: Ia,Ib,Ic.

    Percentage of No-load loss and No-load current: Po,Io%.

    Load loss, impedance voltage percentage, short circuit impedance: Pt,ekt,Zt.

    Load loss, impedance voltage percentage and short circuit impedance at any specified temperature.

    Transformer actual capacity and judged capacity.

     

    Main Technical Parameters

     

    Current measurement range: 100mA-60A,accuracy:class 0.2.

    Voltage measurement range: 10V-650V,accuracy:class 0.2.

    External transformer can broaden the measurement range of instrument.

    Frequency measurement range: 40-65Hz, accuracy:class 0.2.

    Power input: AC220V± 10%.

    Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment

     

    Photo Show:

    Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment
    Transformer Load and No-Load Characteristics Analyzer Capacity Tester Test Equipment

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier