Automatic Relay Protection Test System Three Phase Relay Protection Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Three Phase Relay Protection Tester
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Automatic Relay Protection Test System Three Phase Relay Protection Tester
  • Automatic Relay Protection Test System Three Phase Relay Protection Tester
  • Automatic Relay Protection Test System Three Phase Relay Protection Tester
  • Automatic Relay Protection Test System Three Phase Relay Protection Tester
  • Automatic Relay Protection Test System Three Phase Relay Protection Tester
  • Automatic Relay Protection Test System Three Phase Relay Protection Tester
Find Similar Products

Basic Info.

Model NO.
GDJB-PC
Output Accuracy
0.5magnitude
Three Parallel Phase Current Output
0~120A
Phase Current Maximum Power Output
420va
Three Parallel Phase Current Max Power O
900va
Frequency Range (Base Wave)
20~1000Hz
Application
3 Phase Protection Relay System Testing
Output
3 Phase Current and 3 Phase Voltage Output
Transport Package
Plywood Case
Specification
25KG
Trademark
GOLD
Origin
Chongqing
HS Code
9030849000
Production Capacity
500pieces/Month

Product Description

Automatic Relay Protection Test System Three Phase Relay Protection Tester

Automatic Relay Protection Test System Three Phase Relay Protection Tester


What is the difference between Primary & Secondary injection test?


A primary injection test set injects a multiple of the fault rated current of the breaker, through the breaker while measuring the trip time. The secondary injection test injects a ratio of the fault rated current of the breaker directly into the trip unit and measures how long it takes the breaker to trip. Another way to look at this is a primary injection test tests the breaker as close to a real-world scenario as you can while secondary injection tests the timing and function of the trip unit.

Automatic Relay Protection Test System Three Phase Relay Protection Tester
Automatic Relay Protection Test System Three Phase Relay Protection Tester
                     secondary injection tester                                                                                                      primary injection tester
 

Introduction:

  • GDJB-PC Automatic Relay Protection Test System/Relay and Protection Testing Equipment/Three Phase Relay Protection Tester is applied to test the relay unit in relay protection system. At the same time it could be considered as a universal three phase AC/DC voltage source or current source.

  • Automatic Relay Protection Test System/Relay and Protection Testing Equipment/Three Phase Relay Protection Tester is applied to test protection replay based on voltage and current operation.

  • The main function of the tester include: calibration of voltage and current operation relays, secondary circuit inspection,trip value of circuit breaker test, switch on and off time measurement of circuit breaker and so on.

  • It's a low cost, simple operation and reliable performance device for secondary circuit test.

 

Specifications:

No.

Items

Specifications

Alternating Current(AC) output

1

Output accuracy

0.5magnitude

2

Phase current output (effective value)

0~40A

3

Three parallel phase current output (effective value)

0~120A

4

Phase current value with long time under permission (effective value)

10A

5

Phase current maximum power output

420VA

6

Three parallel phase current maximum power output

900VA

7

Three parallel phase current maximum work time

10s

8

Frequency range (base wave)

20~1000Hz

9

Harmonic frequency number

1~20 time

Direct Current(DC) output

1

Output accuracy

0.5magnitude

2

Current output

0 ~ ± 10 A/each phase

0 ~ ± 30 A/every three parallel

3

Maximum output of load voltage

20v

Alternating Voltage output

1

Output accuracy

0.5magnitude

2

Phase voltage output (RMS)

0 ~ 120v

3

Line voltage output (RMS)

0 ~ 240v

4

Phase voltage/line voltage power output

80VA/100VA

5

Frequency range (base wave)

20 ~ 1000Hz

6

Harmonic frequency number

1 ~ 20 times

Direct voltage output

1

Output accuracy

0.5magnitude

2

Phase voltage output amplitude

0 ~ +160v

3

Line voltage output amplitude

0 ~ + 320v

4

Phase voltage/line voltage power output

70VA/140VA

The switch quantity and time measurement

1

Switch parameters input

7 ways;

Empty contact: 1~20mA, 24v

Power contact access: "0":0~ +6V;  

"1":+11 V ~ +250V

2

Switch parameters output

2 couples  DC:220V/0.2A;   AC:220V/0.5A

3

Time measurement

Measuring range: 0.1ms ~ 9999s / 0.1ms