A primary injection test set injects a multiple of the fault rated current of the breaker, through the breaker while measuring the trip time. The secondary injection test injects a ratio of the fault rated current of the breaker directly into the trip unit and measures how long it takes the breaker to trip. Another way to look at this is a primary injection test tests the breaker as close to a real-world scenario as you can while secondary injection tests the timing and function of the trip unit.
Introduction:
GDJB-PC Automatic Relay Protection Test System/Relay and Protection Testing Equipment/Three Phase Relay Protection Tester is applied to test the relay unit in relay protection system. At the same time it could be considered as a universal three phase AC/DC voltage source or current source.
Automatic Relay Protection Test System/Relay and Protection Testing Equipment/Three Phase Relay Protection Tester is applied to test protection replay based on voltage and current operation.
The main function of the tester include: calibration of voltage and current operation relays, secondary circuit inspection,trip value of circuit breaker test, switch on and off time measurement of circuit breaker and so on.
It's a low cost, simple operation and reliable performance device for secondary circuit test.
Specifications:
No. |
Items |
Specifications |
|||
Alternating Current(AC) output |
|||||
1 |
Output accuracy |
0.5magnitude |
|||
2 |
Phase current output (effective value) |
0~40A |
|||
3 |
Three parallel phase current output (effective value) |
0~120A |
|||
4 |
Phase current value with long time under permission (effective value) |
10A |
|||
5 |
Phase current maximum power output |
420VA |
|||
6 |
Three parallel phase current maximum power output |
900VA |
|||
7 |
Three parallel phase current maximum work time |
10s |
|||
8 |
Frequency range (base wave) |
20~1000Hz |
|||
9 |
Harmonic frequency number |
1~20 time |
|||
Direct Current(DC) output |
|||||
1 |
Output accuracy |
0.5magnitude |
|||
2 |
Current output |
0 ~ ± 10 A/each phase 0 ~ ± 30 A/every three parallel |
|||
3 |
Maximum output of load voltage |
20v |
|||
Alternating Voltage output |
|||||
1 |
Output accuracy |
0.5magnitude |
|||
2 |
Phase voltage output (RMS) |
0 ~ 120v |
|||
3 |
Line voltage output (RMS) |
0 ~ 240v |
|||
4 |
Phase voltage/line voltage power output |
80VA/100VA |
|||
5 |
Frequency range (base wave) |
20 ~ 1000Hz |
|||
6 |
Harmonic frequency number |
1 ~ 20 times |
|||
Direct voltage output |
|||||
1 |
Output accuracy |
0.5magnitude |
|||
2 |
Phase voltage output amplitude |
0 ~ +160v |
|||
3 |
Line voltage output amplitude |
0 ~ + 320v |
|||
4 |
Phase voltage/line voltage power output |
70VA/140VA |
|||
The switch quantity and time measurement |
|||||
1 |
Switch parameters input |
7 ways; Empty contact: 1~20mA, 24v Power contact access: "0":0~ +6V; "1":+11 V ~ +250V |
|||
2 |
Switch parameters output |
2 couples DC:220V/0.2A; AC:220V/0.5A |
|||
3 |
Time measurement |
Measuring range: 0.1ms ~ 9999s / 0.1ms |