Customization: | Available |
---|---|
After-sales Service: | Life Time Support |
Warranty: | 1 Year for Contact Resistance Tester Relay Test Se |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Functions
1) Measurement of closing time, opening time, time spread between poles, time spread between units of one pole, bounces etc.
2) Measurement of closing speed, opening speed and average speed.
3) Measurement of clearance between open contacts, over travel, overshoot travel and total travel.
4) Measurement of closing coil current time curve, opening coil current time curve and the maximum coil current.
5) Test travel time curve, speed time curve and acceleration time curve.
6) Measurement of pre-insertion resistance value and pre-insertion ion time.
7) Test contact resistance.
8) Measurement of dynamic resistance time curve and length for arcing contacts.
10) Vibration test, including vibration fingerprint curve acquisition, management, and vibration fingerprint curve automatic matching.
11) CO-t1-CO,O-t-CO-t1-CO,CO rated operating sequence verification test.
12) Drawing Envelopes for reference travel curve and compare travel curve with envelopes.
13) Mechanical travel curve automatic compare with saved travel curve.
14) Measurement of CO time (close-open time) and OC time (Opening-Closing time).
15) Graphite contact closing time, opening time, dynamic resistance curve measurement.
16) Zoom, editors, statistics and analysis for measurement curves.
17)12.1-inch touch screen for control and data input.
18) Built-in micro printer for test result printout.
19) Generate WORD format test report automatically (all reports and data can be exported through Flash disk).
Technique index
12 channels for time measurement |
3-channel supports both the time contact and resistance contact time 6-channel isolated contacts for cascaded unit measurement of pole |
Time measurement | Range: 4000ms Error :< 0.1ms Resolution: 0.01ms Linear resistance sensor: |
Travel measurement according to sensor |
Linear resistance sensor Measurement range: 0~250mm; resolution: 0.01mm; error:<0.5mm Measurement range: 0~25mm; resolution: 0.01mm; error:<0.05mm Angle resistance sensor: Measurement range: 0~360°; resolution: 0.01°; error:<0.5° |
Pre-insertion Resistance Measurement |
Range: 50~5000ohm; error :<1%RDG+2D |
Dynamic resistance measurement |
Test current: 25~100A Measurement error :< 1%RDG+2D |
Contact resistance measurement |
Range:0--10mohm ; Error<0.5%RDG+0.05%FS Range: 0-2mohm; Error:<0.5%RDG+2D |
Speed measurement | 250mm linear resistance scale: 0~20m/s; error:<0.5%RDG+2D 25mm linear resistance scale: 0~20m/s; error:<0.5%RDG+2D Angle sensor: 0~20m/s; error:<0.5%RDG+2D Acceleration sensor: 0~20m/s; error:<5%RDG+2D |
Coil current measurement | Range: 0~20A; resolution: 0.001A; error:<0.01A |
Vibration measurement | Range: 0~5000G; error:<3% |
Internal DC power source | Voltage: 12~265V; current:0~20A |
Data Save | Built-in 8G storage memory and 2 USB interface for data export and external keyboard or mouse connection |
Power supply | AC220V±10%; 50Hz±10% |
Working environment | Temperature: -10~50°C; Humidity:<80% |
On site use