Customization: | Available |
---|---|
After-sales Service: | Lifetime Technical Support |
Warranty: | 1 Year for CT PT Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The GDVA-405 CT PT Analyzer is an advanced and state-of-the-art professional instrument specifically engineered to provide comprehensive testing and analysis capabilities for current transformers (CTs) and potential transformers (PTs). With its cutting-edge technology and precise measurement capabilities, this instrument plays a crucial role in the industry by facilitating accurate assessment and evaluation of transformer performance.
Built with the latest advancements in testing equipment, the CT PT Analyzer offers a wide range of features and functionalities that enable thorough examination of CTs and PTs. It is designed to meet the stringent requirements of the industry, ensuring reliable and accurate results.
Test Items by GDVA-405 CT PT Analyzer:
Tests for Current Transformer | Tests for Potencial Transformer |
1) Turn ratio detection
2) Ratio and angle error check
3) Polarity test
4) Excitation characteristic test
5) Secondary winding resistance measurement and secondary burden measurement
6) 5% and 10% error curve measurement
7) Transient characteristics analysis
8) Automatic nameplate inference
9) Knee point voltage/current
10) Accuracy Limit Factor (ALF)
11) Instrument security factor (FS)
12) Secondary time constant (Ts)
13) Remanence coefficient (Kr)
14) Accuracy
15) Saturation and desaturation inductance
16) Knee point electromotive force
17) Limit electromotive force
18) Area factor
19) Iron core analysis and core hysteresis loop measurement
|
1) Turn ratio measurement
2) Ratio and angle error check
3) Polarity test
4) Excitation characteristic test
5) Primary winding resistance test
6) Secondary winding resistance test
7) Secondary burden measurement
|
Technical Parameter of GDVA-405 IEC60044 Transformer CVT Test Machine CT Meter Automatic CT PT Analyzer
1.Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC61869,IEC60044-5, C57.13 2.Power supply: AC220V±10%, 50/60Hz±10% 3.Voltage output: 0.1-180V (AC) 4.Current output: 0.001-5A(RMS) 5.Power output: 500VA 6.Maximum knee voltage measurement: 60KV 7.Current measurement: Range: 0-10A (automatically change range in 0.1/0.4/2/10A) Error: <±0.1%+0.01%FS 8.Voltage measurement: Range: 0-200V (automatically change range in 1V/10V/70V/200V) Error: < ±0.1%+0.01%FS 9.Turns ratio measurement: Range:1-35000 1-2000 error<0.05% 2000-5000 error<0.1% 5000-35000 error<0.2% 10.Phase measurement: error: ±2min; resolution: 0.01min. 11.Winding resistance measurement: Range: 0-8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error: < 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ 12.Temperature measurement:-50~100 Celsius degree; error<3 Celsius degree. |
13.CT Secondary burden: Range: 0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error: <0.2%RDG+0.02%FS Maximum resolution: 0.001ohm 14.PT Secondary burden: Range: 0-80kohm (automatically change range in 800ohm/8kohm/80kohm) Error :<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15.PT ratio measurement: Range: 1-35000 1-10000 error<0.1% 10000-35000 error<0.2% 16.PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%. 17.PT phase angle measurement: maximum error < 3min. 18.Memory capacity: >1000 groups test results. 19.Working condition: temperature: -10ºC~50ºC; moist: ≤90% |