0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • 0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
  • 0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
  • 0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
  • 0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
  • 0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
  • 0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
Find Similar Products

Basic Info.

Model NO.
GDVA-405 CT PT Tester
Test Standards
IEC60044-1/6/2/5, IEC61869-2,C57.13
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Power Output
500va
Max. Knee Voltage Measurement
45kv
Current Measurement Range
0~10A
Voltage Measurement Range
0~200V
CT Secondary Burden Range
0~160ohm
PT Secondary Burden Range
0~80kohm
Transport Package
Plywood Case for CT PT Tester
Specification
30KG
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Sets/Month

Product Description

0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester 

0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester

Application:

Tests for current transformer:

  • Excitation curve and parameters test

  • Turns ratio test

  • Ratio and phase error test

  • Polarity mark check

  • Winding resistance measurement

  • Secondary loop burden measurement

  • Error line curve test for protection CT

  • Transient CT parameters test

  • CT nameplate guess

  • Saturation hysteresis loop curve measurement

  • Tests for Potencial Transformer:

  • Turns ratio test

  • Ratio error and phase angle error test

  • Polarity test

  • Secondary burden test

  • Winding resistance test

 

Applications of CT/ PT Analyzer:

  • CT nameplate check

  • CT parameters check in work burden

  • CT transient parameters analysis

  • CT ratio and phase error calibration

  • PT routine test

 

Specifications:

Item Name 0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
Test standards IEC60044-1, IEC60044-6, IEC61869-2,IEC60044-2, IEC60044-5, C57.13
Power supply  AC220V±10%, 50/60Hz±10%
Voltage output  0.1~180V (AC)
Current output  0.001~5A(RMS)
Power output  500VA
Max.  knee voltage measurement  45KV
Current measurement
 
 
  Range 0~10A (automatically change  range in 0.1/0.4/2/10A)
  Error  <±0.1%+0.01%FS

 

Voltage measurement
 
 Range 0~200V (automatically change range in 1V/10V/70V/200V)
 Error < ±0.1%+0.01%FS
Turns ratio measurement Range
  
1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement   error  ±2min
resolution  0.01min
Winding resistance measurement
    
   
Range 0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
Error  < 0.2%RDG+0.02%FS
Maximum resolution :  0.1mΩ
Temperature measurement -50~100 Celsius degree; error<3 Celsius degree
CT Secondary burden Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error  <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
   
  
PT Secondary burden
 
Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution : 0.1ohm
   
PT ratio measurement
Range

1~35000,

1~10000 error<0.1%, 

10000~35000 error<0.2%

PT ratio error measurement :Typical error<0.05%,  Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window
Memory capacity  >1000 groups test results
Working condition temperature  -10ºC~50ºC; moist ≤90%


Customer Visiting

0.02 Class Automatic Current Transformer Angle Error Ratio Error Testing CT PT Characteristic Tester
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.