Customization: | Available |
---|---|
Power Source: | AC220V |
Product Name: | Automatic ASTM D92 Flash Point Analyzer |
Still deciding? Get samples of US$ 5/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introduction:
open cup flash point test apparatus of ethanol is designed and made as per ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester.
open cup flash point test apparatus of ethanol is applicable to all petroleum products with flash points above 79ºC and below 400ºC except fuel oils.
Features:
1 |
Open cup flash point test appratus adopts LCD screen to display and full English man-machine interface. It can preset expected flash point temperature, sample mark number, barometric pressure and other parameters.It has menu prompt and input guide. |
2 |
Open cup flash point test appratus adopts simulation tracking to display the function curve of temperature rising and test time. It has the functions of English mis-operation prompt,test date,test time and other parameters. |
3 |
Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value |
4 |
Differential coefficient detection.Automatically correct the system deviation. |
5 |
Automatically open the lid,detect the flash point and print test data.The test arm automatically rise up and lower down. |
6 |
Reasonable design, safe and convenient to operate. |
Specifications:
Product name | Automatic ASTM D92 Cleveland Open Cup Flash Point Test Apparatus of Ethanol |
Power supply | AC220(-10%~+5%)V, 50Hz |
Flash point determination | Range:Ambient to 400ºC Repeatability:≤8ºC Reproducibility:≤17ºC Accuracy:0.1ºC |
Heating rate | Correspond with GB/T3536 and ASTM D92 |
Ignition mode | Electric ignition. Gas flame diameter is 3.2mm~4.8mm |
Ambient temperature | (10~40)ºC |
Relative humidity | ≤80% |
Maximum power consumption | 400W |
Dimension | 410*360*310mm |
GD-3536 Series ASTM D92 CLEVELAND OPEN CUP FLASH POINT TESTER:
Parameter |
GD-3536 |
GD-3536-1 |
GD-3536A |
GD-3536D |
Temperature range |
Ambient temperature~400ºC |
Ambient temperature~400ºC |
Ambient temperature~400ºC |
Ambient temperature~400ºC |
Ignition mode |
Ignite once manually |
Ignite once manually |
Ignite once manually |
Automatic |
Temperature display |
Thermometer |
LCD |
Color LCD |
Color LCD |
Printing |
No |
No |
Yes |
Yes |
Communication port |
No |
No |
No |
Yes |
Other function |
Manually adjust heating rate |
Automatically control temperature and display by LCD |
Automatic |
Automatic, with RS232 communication port |
Dimension |
350*290*350mm |
340*320*450mm |
410*360*420mm |
520*380*310mm |