Volt-Ampere Characteristic Tester CT PT Transformer Analyzer

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for CT PT Vt Transformer Analyzer
Still deciding? Get samples of US$ 7500/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Volt-Ampere Characteristic Tester CT PT Transformer Analyzer
  • Volt-Ampere Characteristic Tester CT PT Transformer Analyzer
  • Volt-Ampere Characteristic Tester CT PT Transformer Analyzer
  • Volt-Ampere Characteristic Tester CT PT Transformer Analyzer
  • Volt-Ampere Characteristic Tester CT PT Transformer Analyzer
  • Volt-Ampere Characteristic Tester CT PT Transformer Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Test Items
  • Applications
  • Product Parameters
  • Detailed Photos
  • Packing list
Overview

Basic Info.

Model NO.
GDVA-405
Product Name
Volt-Ampere Characteristic CT Transformer Tester
Usage
Transformer Tester
Test Standards
IEC60044-1/2/5/6
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Current Measurement Range
0~10A
Secondary Current
1A,3A,5A
Power Output
500va
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

Volt-ampere Characteristic Tester CT PT Transformer Analyzer

Volt-Ampere Characteristic Tester CT PT Transformer Analyzer

Product Description

It is based on the well-received and applied fully automatic FA series transformer universal tester produced by our company. The use of high-performance DSP and ARM can complete the data acquisition of the variable frequency power supply control and test process, and the advanced manufacturing process ensures that the product performance is stable and reliable, with complete functions, high degree of automation and high efficiency. It is at the leading level in China and is a professional test equipment for transformer inspection in the power industry. All data analysis, storage and interface display are completed by the industrial computer system.

Test Items
 

1. Excitation curve and parameters test
2. Turns ratio test
3. Ratio and phase error test
4. Polarity mark check
5. Winding resistance measurement
6. Secondary loop burden measurement
7. Error line curve test for protection CT
8. Transient CT parameters test
9. CT nameplate guess
10. Saturation hysteresis loop curve measurement

Tests for Potencial Transformer :
1. Turns ratio test
2. Ratio error and phase angle error test
3. Polarity test
4. Secondary burden test
5. Winding resistance test

Applications


1. CT nameplate check
2. CT parameters check in work burden
3. CT transient parameters analysis
4. CT ratio and phase error calibration
5. PT routine test

 

Product Parameters

 

GDVA-405 CT PT Analyzer
1 Test standards IEC60044-1/2/5/6, GB1208, GB61869, C57.13
2 Power supply AC220V±10%,50Hz/60Hz±10%
3 Power output 0.1~125V (AC)
4 Current output 0.001~5A(RMS)
5 Power output 300VA
6 Max. knee voltage measurement 45kv
7 Current measurement range 0~10A (automatically change range in 0.1/0.4/2/10A)
8 Current measurement error <±0.1%+0.01%FS
9 Voltage measurement range 0~200 V (automatically change range in 1V/10V/70V/200V)
10 Voltage measurement error < ±0.1%+0.01%FS
11 Turns ratio measurement range 1~30000;
1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2%
12 Phase measurement error:±2min,resolution:0.01min
13 Coil resistance measurement Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ
14 Temperature measurement -50~100 Celsius degree, error<3 Celsius degree
15 CT Secondary burden Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm
16 PT Secondary burden Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)
Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm
17 PT ratio measurement Range: 1~30000, 1~5000 error<0.2% 5000~30000 error<0.5%
18 Saved data groups >1000 groups
19 Work condition Temperature:-10ºC-50ºC, moist:≤90%
20 Size 49*36*19cm
21 Net Weight 15kg
 
Detailed Photos

Volt-Ampere Characteristic Tester CT PT Transformer Analyzer

Volt-Ampere Characteristic Tester CT PT Transformer Analyzer

Volt-Ampere Characteristic Tester CT PT Transformer Analyzer
Volt-Ampere Characteristic Tester CT PT Transformer AnalyzerVolt-Ampere Characteristic Tester CT PT Transformer AnalyzerVolt-Ampere Characteristic Tester CT PT Transformer Analyzer
Packing list

 

Volt-Ampere Characteristic Tester CT PT Transformer Analyzer
Name  Quantity  Description
Host machine  1  
3M mask cable  2 Test cable for power out and CT
secondary
connection
10M mask cable 1 Test cable for CT primary connection
Grounding cable 1  
Big test pliers   2 One red and one black
Test gasket  4 Two red and two black
Test pin  4 Two red and two black
Test pliers 12 Three red and nine black
Short connection cable  1 Including six connection terminals
3A fuse 3  
Power cable 1  
Accessories bag  1  
Production disk 1 Include Analysis application and user manual
User manual 2  
Inspection report 1  
Pass certificate 1  
 