• IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire
  • IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire
  • IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire
  • IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire
  • IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire
  • IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire

IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire

After-sales Service: All Life Technical Supports
Warranty: 12 Months
Item Name: IEC 60332-3 Flammability Analyzer Flame Spread
Standard: IEC 60332-3
Application: Flame Spread Chamber Fore Bunched Cable
Size: 1,000(W) * 2,000(D) * 4,000(H)
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-IEC60332-3
Power
220 V AC, 60 Hz, 10 a
Weight
About 500kg
Utilities
Propane Gas Valve System, Ignition System
Burner
with Type Propane Gas Burner
Burner Size
257mm × 4 5mm
Burner Opening a Total of 242
Three Lines Are Arranged
High-Precisionball
Control The Gas off
Two Meter
Airflow and Gas Flow Meter and Control Valve
The Distance Between Holes
3.2 mm
Manual
Provide
Transport Package
Standard Wooden Case
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
500 Sets/ Year

Product Description

IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire

IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire

 

Introduction: 

IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire in accordance with the relevant provisions of GB18380.3 standard and cable burning test requirements designed equipment. And in accordance with IEC 60332-3-10, KS C IEC 60332-3-21 ~ 25 (A ~ Class D) standard.

IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire is used to bundle cable or fiber optic cable to detect vertically mounted under specified conditions for vertical flame spread inhibiting the ability of the instrument, the power cables, control cables, fiber optic cable bundle burning test Preparation means. 

When given a certain amount of housing supply of gas and the use of a standard ignition source of ignition, this IEC 60332-3 Flame Spread Chamber for Bunched Wire can be used to test for vertical flame vertical diffusion to electric cables and wires of state. In addition, if the tester burner adjustment of 20 degrees can be achieved by.

 

Standard:

• IEC 60332-3-10

• EN 50399

• GB/T 18380.31

• IEC 60332-3: Test on Electric cables under fire conditions

 part 3: Test on bunched wires or cables

• KS C IEC 60332-3-21: Category A F/R

• KS C IEC 60332-3-22: Category A

• KS C IEC 60332-3-23: Category B

• KS C IEC 60332-3-24: Category C

• KS C IEC 60332-3-25: Category D

 

Feature: 

1, Stainless steel test box the size of 1,000 ± 100 (W) x 2,000 ± 100 (D) x 4,000 ± 100 (H)mm. The Interior surface of the case than the high ground and the rear side is covered with insulation material;

2, With a standard stainless steel ladder, based on ladders GB / T18380.31 requirements;

3, Alternate sample frame 2;

4, ladders made of stainless steel; Corrosion resistant; easy to clean;

5, In the lower part of the cabinet, from a position in front of the housing 150 ± 10mm has an 800 ± 20 (W) × 400 ±10 (D) of air intake;

6, the inside of the box is mounted thermocouple type K thermocouples, 2mm in diameter;

7, The airflow inside the combustion furnace can be stably controlled at (5000 ± 500) L / min.

 

Combustion System:

1, Burner: with type propane gas burner, size 257mm × 4 5mm, opening a total of 242, three lines are arranged, respectively81,80,81 holes, hole diameter of 1.35mm, the distance between holes is 3.2 mm;

2, High-precision ball, control the gas off;

3, Two meters: airflow and gas flow meter and control valve;

4, The front end of the combustion flame installation tester off the tube to protect the propane gas tempering, so as to ensure maximum safety on the specimen;

5, Combustion angle:horizontal; automatic ignition device(20 degrees adjustable is optional);

6, The burner air and gas flow rate must be supplemented with temperature and pressure, while many traditional systems ignore the impact of gas and air can be done automatically by a computer program in the compensation process.

 

Specification:

Product Name IEC 60332-3 Flammability Analyzer Flame Spread Chamber for Bunched Wire
Size 1,000(w) ×  2,000(D) ×  4,000(H)
Power 220 V AC, 60 Hz, 10 A
Weight About 500kg
Utilities Propane Gas Valve System, Ignition System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters