Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for CT PT Characteristic Tester
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
  • Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
  • Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
  • Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
  • Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
  • Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
Find Similar Products

Basic Info.

Model NO.
GDVA-405
Product Name
Current Power Transformer Tester CT PT Analyzer
Usage
Transformer Tester
Test Standards
IEC60044-1/2/5/6, IEC61869
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Power Supply
220V 50Hz
Current Measurement Range
0~10A
Secondary Current
1A,3A,5A
Power Output
500va
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
 

Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument

Tests for Current Transformer :
1. Excitation curve and parameters test
2. Turns ratio test
3. Ratio and phase error test
4. Polarity mark check
5. Winding resistance measurement
6. Secondary loop burden measurement
7. Error line curve test for protection CT
8. Transient CT parameters test
9. CT nameplate guess
10. Saturation hysteresis loop curve measurement

 

Tests for Potencial Transformer :
1. Turns ratio test
2. Ratio error and phase angle error test
3. Polarity test
4. Secondary burden test
5. Winding resistance test


Applications of CT/ PT Analyzer:
1. CT nameplate check
2. CT parameters check in work burden
3. CT transient parameters analysis
4. CT ratio and phase error calibration
5. PT routine test


Technical index

GDVA-405 CT PT Analyzer
1 Test standards IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2 Power supply AC220V±10%,50Hz/60Hz±10%
3 Power output 0.1~125V (AC)
4 Current output 0.001~5A(RMS)
5 Power output 300VA
6 Max. knee voltage measurement 45kv
7 Current measurement range 0~10A (automatically change range in 0.1/0.4/2/10A)
8 Current measurement error <±0.1%+0.01%FS
9 Voltage measurement range 0~200 V (automatically change range in 1V/10V/70V/200V)
10 Voltage measurement error < ±0.1%+0.01%FS
11 Turns ratio measurement range 1~30000;
1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2%
12 Phase measurement error:±2min,resolution:0.01min
13 Coil resistance measurement Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ
14 Temperature measurement -50~100 Celsius degree, error<3 Celsius degree
15 CT Secondary burden Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm
16 PT Secondary burden Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)
Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm
17 PT ratio measurement Range: 1~30000, 1~5000 error<0.2% 5000~30000 error<0.5%
18 Saved data groups >1000groups
19 Work condition Temperature:-10ºC-50ºC, moist:≤90%
20 Size 70*50*41CM
21 Weight 40kg
 

 Standard configuration for CT/PT Analyzer:

Name  Quantity  Description
Host machine  1  
3M mask cable  2 Test cable for power out and CT
secondary
connection
10M mask cable 1 Test cable for CT primary connection
Grounding cable 1  
Big test pliers   2 One red and one black
Test gasket  4 Two red and two black
Test pin  4 Two red and two black
Test pliers 12 Three red and nine black
Short connection cable  1 Including six connection terminals
3A fuse 3  
Power cable 1  
Accessories bag  1  
Production disk 1 Include Analysis application and user manual
User manual 2  
Inspection report 1  
Pass certificate 1  


Detail show

Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument


Order & Customer Feedback:
Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
Our Company:
Portable High Accuracy CT PT Characteristic Tester CT PT Analysis Instrument
Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd is founded in 2008. We have a strong team including top sales, skilled engineers and we have our own manufacture with high quality. we mainly design and manufacture the Transformer Tester,  Circuit Breaker Analyzer,  CT PT Analyzer, Hipot Tester ,  Relay Tester and so on for more than 20 years.

After several years' development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;

We have developed sales channels in many countries such as UAE, Saudi Arabia, Iran, Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide.
And we have gained strong advantage and high reputation in international market.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier