• BS476-6 Fire Propagation Testing Apparatus for Building Material
  • BS476-6 Fire Propagation Testing Apparatus for Building Material
  • BS476-6 Fire Propagation Testing Apparatus for Building Material
  • BS476-6 Fire Propagation Testing Apparatus for Building Material
  • BS476-6 Fire Propagation Testing Apparatus for Building Material
  • BS476-6 Fire Propagation Testing Apparatus for Building Material

BS476-6 Fire Propagation Testing Apparatus for Building Material

After-sales Service: 7/24 Service
Warranty: One Year
Apparatus: BS476 Part 6 Apparatus for Building Material Fire
Application: Building Material Fire Propagation Testing
Reference Standards: BS476-6, BS476 Part 6,ISO 5658, ASTM E 1317
Control Method: PC Control
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
GD-476-6
Test Time
20 Min
Gas Source
G112
Heating Quartz
1000W * 2, UK Made
Price
Low Price
Power Supply
220V, 50Hz
Transport Package
Stndard Wooden Case
Specification
ISO
Trademark
Gold
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
100PCS/Month

Product Description

BS476 Part 6 Apparatus for Building Material Fire Propagation Testing
 
Product Description

Introduction:

  1. BS 476-6 is a test method of measuring the flame propagation properties of materials, primarily for fire protection performance evaluation of the walls and ceilings, measurement results are expressed as an index of flame propagation.
  2. During the test, the specimen is exposed to the tubular torch, heat release of the lamp is 530J / S. 2 minutes and 45 seconds later, the two electric heaters were adjusted to 1800 watts in total, 5 minutes after starting the test, reduced the power to 1500 watts, keep the power not changed until finishing the experiment, the total test time is 20 minutes.
  3. To assess the flame propagation properties of the material to be tested in BS476-6, the thermocouple continuous recording chimney temperature and room temperature difference, and compared the results with the calibration curve, calibration curve based on the provisions of the density of asbestos-cement slab in the same measured way.
  4. Comparing the temperature difference value of two curves measured at the same time. In the first three minutes of the test, take the temperature difference value every 30 seconds, in the following 4-10 minutes, take the temperature difference value every one minute. In the last 11-20 minutes, take the temperature difference value every two minutes. The flame spread index of these three periods is calculated according to the formula.
  5. It is the value of the sum of the three periods' flame spread index. The higher of I value, the lower the material flame retardant, 0-grade material I≤12.

Reference Standards:
  1. BS 476 Part 6 A1: 2009
  2. GB/T 17658-199
  3. ISO 5658

Features:
  1. Stainless steel cabinet support frame;
  2. Calcium silicate board combustor;
  3. All three sample holders are stainless steel parcels;
  4. 2 sets of 1000W quartz radiation devices, to provide thermal radiation to samples;
  5. T-type burner supplies flame combustion to the sample;
  6. Thermocouple continuous recording temperature and room temperature difference value in the chimney;
  7. The power output is automatically controlled according to the test of time;
  8. The computer automatically processes the data, and prints the test report;
Detailed Photos

 

BS476-6 Fire Propagation Testing Apparatus for Building Material
BS476-6 Fire Propagation Testing Apparatus for Building Material

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters