• Transformer Oil Power Factor Test Set / Tangent Delta Test Kit
  • Transformer Oil Power Factor Test Set / Tangent Delta Test Kit
  • Transformer Oil Power Factor Test Set / Tangent Delta Test Kit
  • Transformer Oil Power Factor Test Set / Tangent Delta Test Kit
  • Transformer Oil Power Factor Test Set / Tangent Delta Test Kit
  • Transformer Oil Power Factor Test Set / Tangent Delta Test Kit

Transformer Oil Power Factor Test Set / Tangent Delta Test Kit

After-sales Service: Life Time Support
Warranty: 1 Year for Transformer Oil Power Factor Test Set
Type: Tan Delta Test Equipment
Load Way: Electronic Load
Loading Method: Dynamic Load
Display: Digital
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDGY
Control
Digital Control
Power Source
AC220V
Product Name
Transformer Tan Delta and Power Factor Tester
Tangent Delta
1%Rdg+0.04%
Application Field
High Voltage Electrical Equipments in Power Plants
Operating Type
Fully Automatic
Capacitor Value
1%Rgd+5PF
Environment Temperature
0-50°c
Transport Package
Wooden Case
Specification
450*310*360mm
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
200PCS/Month Tan Delta Tester

Product Description

Transformer Oil Power Factor Test Set / Tangent Delta Test Kit
 
Transformer Oil Power Factor Test Set / Tangent Delta Test Kit

1.Introduction

GDGY Automatic Transformer Power Factor Tester, Transformer Tan Delta Tester is a high-precision instrument, which can be applied to measure electrical loss tangent and capacitance of all kinds of high voltage electrical equipment in power plants, substations, laboratory, etc.

 

2. Tan delta meter Specifications

Accuracy:                       Cx       ±(reading×1%+1pF)

                                      PF       ±(reading×1%+0.00040)

Interference Ratio:           Interference current is no more than 2 times of the test current

PF Range:                       No limit, Resolution 0.001%, C/L/R specimen test

Input current range:         10μA~1A

Internal HV:                   0.5~10kV / 200mA (max)

HV Adjust:                     Rise or fall smoothly

HV Accuracy:                ±(reading×1%+10V) Resolving 1V

Frequency select:            60Hz single point, locked 55Hz/65Hz double point, locked

Test Time:                     40S typical

Power Supply:                180V~270V 50Hz/60Hz auto

Operating Temperature:  0ºC~60ºC

storage Temperature:    -20ºC~60ºC

Humidity:                      <90%

 

3.Tan delta meter

Tan Delta (TD) - also referred to as Dissipation Factor or sometime even Power Factor - is an excellent diagnostic test that provides an indication as to the quality of the dielectric insulation used in electrical apparatus. By analyzing the dielectric losses in theinsulation, the GDGS Series of Tan Delta test instruments provide the testing engineer with a versatile high voltage diagnostic system that is suitable for testing MV cable such as XLPE, EPR, PE and PILC. In addition, other electrical apparatus such as capacitors, transformers and large rotating machines can also be diagnosed

 

4.Item show
Transformer Oil Power Factor Test Set / Tangent Delta Test KitTransformer Oil Power Factor Test Set / Tangent Delta Test KitTransformer Oil Power Factor Test Set / Tangent Delta Test Kit
Transformer Oil Power Factor Test Set / Tangent Delta Test Kit


Transformer Oil Power Factor Test Set / Tangent Delta Test Kit




 




About Us
Transformer Oil Power Factor Test Set / Tangent Delta Test Kit

Chongqing Gold Mechanical&Electrical Equipment Co.,Ltd was founded in 2008. We have a strong team including top sales, skilled engineers and we have our own manufacture with high quality. we mainly design and manufacture the Transformer TesterCircuit Breaker AnalyzerCT PT AnalyzerHipot Tester , Relay Tester and so on for more than 10 years.
After several years' development, our products have become high intelligent and wide coverage. And our company has become one of the leading manufacturer of oil purifier and electrical testing equipment in China;
We have developed sales channels in many countries such as UAE, Saudi Arabia, Iran, Malaysia, Thailand, Pakistan, India, Germany, Belgium, USA, Mexico, Kenya, Nigeria, South Africa and other countries worldwide.
And we have gained strong advantage and high reputation in international market.



Our workshop
Transformer Oil Power Factor Test Set / Tangent Delta Test Kit



Certificates
Transformer Oil Power Factor Test Set / Tangent Delta Test Kit



Customer visit
Transformer Oil Power Factor Test Set / Tangent Delta Test Kit



International exhibitions
Transformer Oil Power Factor Test Set / Tangent Delta Test Kit



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters