Model No. | GD-H1706 |
Applicable standards | SH/T0703, ASTM D5481 |
Heating method | By electrical bar |
Test temperature | Room temperature ~ 150ºC |
Temperature control accuracy | ±0.1ºC |
Working unit | 1 unit |
Control method | Touch LCD screen |
Results calculation | Windows high temperature high shear viscosity calculation software |
Screen display content | Test pressure, test time, sample constant temperature time |
Working power supply | AC220V, 50/60HZ |
Total power | 500W |
Dimension | 400*430*850mm |
Net weight | 35KG |
1.This instrument has been widely used by many customers in China and and outside China.
2.The accessories can be exchanged with imported equipment.
3.Equipped with a special high shear viscosity calculation software.
4.The instrument allows 24 hours a day and running continuously for 365 days.
5.No solvent cleaning is required, only a small amount of fresh sample is required for rinsing.
6.The glass capillary tube meets the standard requirements, with a diameter of 0.15mm and a length of 16mm.
7.For the purpose of research, users can set different shear rate and test temperature.
8.Made of all aluminum materials.
9.Touch LCD control, can be operated directly on the LCD screen.
10.The software automatically recommends the test pressure, and the test results can be generated by Excel report.
11.We're patented for the oil shear viscometer, the patent No. is ZL201821712254.6
1)Power
After the instrument is powered on, the exhaust fan starts to work, and the touch screen starts to display.
2)Heating
The heating part of the instrument is a metal bath made of aluminum alloy, which is heated by a heating rod, and the viscometer cell is installed in it.It takes about 30 minutes to heat the temperature from room temperature to 150 ºC, so it is necessary to turn on the instrument for heating before starting the experiment.
3)Pressure adjustment
After the nitrogen source is connected with the instrument, the instrument can be pressurized. There is a gas cylinder inside the instrument to provide pressure for the instrument during the experiment, and the external nitrogen source only supplies gas to the gas cylinder.
4)Start/stop experiment
In the normal experiment process, click [start / stop experiment] to start the experiment. The experiment is carried out automatically. Under normal circumstances, the experiment will stop automatically, and there is no need to end it manually.
5)Timing
Clicking the constant temperature timer will start a 15min timer to indicate the heating time.
6)Setting
Click [Set] button to switch to the setting page. Click the input box, the user can enter the operator and sample ID on the right side of the page, in order to distinguish in the result query.
7)Results query
This instrument can record the results of the experiments made by users, and the number of records is more than 30,000.
Pre-sale Service | 1.The professional sales team will reply to the inquiry in real time; | |
2.Customize suitable solutions according to the needs of different customers; | ||
3.Provide product technical parameters/operation manuals and evaluation reports, etc.; | ||
After-sale Service | 1.From the date of purchase within one year instrument, is a product quality problem free repair replacement, lifetime supply of maintenance and technical services. | |
2.Technical Support |
(1)Our technical team supports our customers at all time with our long experience, expert advice and the unlimited spirit and always be for providing the best customer service. | |
(2)Training how to install the machine,you can arrange your engineer to our company to get free training. | ||
(3)If necessary, we can also arrange our engineer to your company for training and commissioning at your cost. | ||
3.The instrument has found anomalies or malfunctions please contact us to arrange the most convenient treatment options. |
Welcome to contact us talk about details if you are interested in ASTM D5481 Apparent Viscosity Test High Temperature High Shear Rate Rotational Viscosity of Oils. If you want to know more information,Don't hesitation, welcome your inquiry!Price can be negotiated!