GD-4508G-1 Bitumen Ductility Machine ASTM D6084 for Bitumen CRMB Elastic Recovery Test
Definition:
Ductility is the ability of a material to undergo a visible enduring deformation through elongation (decreasing of cross section area). It expresses the extent to which the material can be plastically deformed without fracture. The opposite material behavior is brittleness.
The test for elastic recovery is applicable to binders modified with elastomers and serves to demonstrate the modification of the binder. The sample is stretched at a fixed temperature and speed to a maximum of 20 cm and then severed. After a prescribed period of time, the degree of elastic recovery is determined relative to the original length.
Reference Standard:
1. GB/T 4508 "Standard Test Method for Ductility of Bitumen".
2. T 0605-2011 "Standard Test Method for Ductility of Bituminous Materials" in JTG E20-2011 "Application Handbook of Standard Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering".
3. NB/SH/T 0814 "Force Ductility Test of Bituminous Materials."
4. NB/SH/T 0737 "Standard Test Method for Elastic Recovery of Asphalt Materials by Ductilometer."
5. T 0662-2000 "Standard Test Method for Elastic Recovery of Asphalt Materials by Ductilometer" in "Application Handbook of Standard Test Methods of Bitumen and Bituminous Mixtures for Highway Engineering".
6. ASTM D113-17 "Standard Test Method for Ductility of Asphalt Materials". ASTM D6084-06 "Standard Test Method for Elastic Recovery of Asphalt Materials by Ductilometer".
Key Features:
1. This instrument is multi-purpose, it is a multifunctional asphalt tester integrating asphalt ductility test, asphalt force-ductility test and asphalt elastic recovery test.
2. It adopts industrial control touch screen, advanced technology which can achieve data transmission function.
3. The novel tension transmission design adopts the combination of imported screw and guide rail. The stretching process is smooth and synchronous, no ditter, uniform speed, the ductility and tensile force are precisely displayed.
4. It adopts high-power compressor refrigeration, shielded cold and heat balance pressurized circulation system, fast cooling speed and uniform bath temperature.
5. It can do the tensile test, force test and elastic recovery test of 3 samples at a time.
6. The average ductility value, the maximum tensile force, and the elongation deformation value at the maximum tensile force are automatically calculated and displayed.
7. The designed two-layer structure of the ductility water bath was granted a national patent, the Patent No. is ZL201821604657.9.
Main Parameters:
1. Working power: AC (220 ± 10%) V, 50Hz
2. Measurement range: 1.5m (±10mm)
3. Heating method: heating tube heating
4. Heating power: 4500W
5. Bath liquid circulation: cold and heat balance circulation system
6. Temperature control range: 5ºC ~ 50ºC adjustable, digital display, temperature display resolution 0.01ºC
7. Temperature control accuracy: ± 0.1ºC
8. Tensile speed: 1cm / min, 5cm / min two files
9. Measurement accuracy: ± 1mm
10. Ductility display: industrial control touch screen real-time display
11. Ductility record: (1) Record by hand-held remote control button
(2) Record by industrial control touch screen "record" button
12. Force measurement range: (0~300)N
13. Force measurement accuracy: ± 1N
14. Display resolution: 0.1N
15. Tensile force display: industrial control touch screen real-time display
16. Data output: industrial control touch screen real-time display, integrated data upload
17. Refrigeration form: 1.25HP compressor refrigeration, input power 950W
18. Ambient temperature: 15ºC ~ 35ºC
19. Relative humidity: ≤85%
20. Dimensions: 2370mm*530mm*950mm
21. Overall Power Consumption: ≤ 5600W