• Current Transformer Temperature Rise Testing Machine CT Thermal Rise Automation Test Device
  • Current Transformer Temperature Rise Testing Machine CT Thermal Rise Automation Test Device
  • Current Transformer Temperature Rise Testing Machine CT Thermal Rise Automation Test Device
  • Current Transformer Temperature Rise Testing Machine CT Thermal Rise Automation Test Device

Current Transformer Temperature Rise Testing Machine CT Thermal Rise Automation Test Device

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for CT Thermal Rise Automation Test Device
Type: CT Thermal Rise Automation Test Device
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 4000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDCW
Display
Digital
Control
Manual Control
Weight
Ask The Salesman
Power Source
AC220V
Product Name
Current Transformer Temperature Rise Testing Machi
Test Standard
IEC 60044/IEEE C57.13
Power Supply
AC220V,45Hz~65Hz
Current Booster Output Capacity
50kVA
Time Measurement and Recording Error
0.1ms
CT Temperature Monitoring Points
12
Maximum Output Current
0~5000A (Greater Output Current Is Customizable)
DC Resistance Measurement Range
0~200 Ohm
Transport Package
Wooden Case
Specification
ask the salesman
Trademark
GOLD
Origin
Chongqing, China
Production Capacity
200sets/Month

Product Description

Current Transformer Temperature Rise Testing Machine CT Thermal Rise Automation Test Device
Current Transformer Temperature Rise Testing Machine CT Thermal Rise Automation Test Device
Product Introduction

GDCW current transformer temperature rise automation test device in accordance with the national grid standard <<GB1206 current transformer>> and the State Grid Corporation standard <<Q/GDW1572 metering current transformer technical specifications>> and other requirements to complete the current transformer temperature rise detection test fully automatically. According to the rated current size of the connected current transformer, the device automatically controls the electronic booster to rise to the target test current required by the standard, and in the process uninterruptedly monitors the temperature of the body of the current transformer, the temperature of the winding joints, the ambient temperature, etc., and automatically determines whether the current transformer has reached thermal stability on the basis of the measured temperature value and the standard requirement of the temperature rise stability conditions. When the temperature rise of the current transformer has reached stability, the device measures the DC resistance of the current transformer coil, and calculates the maximum temperature of the coil winding resistance after the current transformer has reached thermal stability and the maximum temperature rise during the test based on the winding resistance at this time and the DC resistance of the coil winding before the current rise.

Product Advantages
 
Compared with the current manual measurement of current transformer temperature rise test device has the following obvious advantages:

1.GDCW current transformer temperature rise automation test device can simultaneously measure the temperature rise of 5 current transformers, test efficiency is greatly improved.

2. Automatic adjustment of the output current size during the test, so that the test current and the target current error is always less than 0.5%, will not be due to changes in the resistance of the main circuit, grid voltage fluctuations and other factors causing large fluctuations in the test current, so that the test process is more convincing.

3. Real-time monitoring and recording of the temperature of the current transformer body, winding resistance joints and the environment, and automatically determine the temperature rise of the current transformer thermal stability conditions, to avoid errors in human judgement.

4 current transformer to achieve thermal stability, rapid measurement of current transformer winding resistance, to avoid manual wiring test time delay caused by the temperature rise value measurement error.

5 automatic switching of the current transformer secondary circuit load, to avoid possible errors caused by manual operation.
Current Transformer Temperature Rise Testing Machine CT Thermal Rise Automation Test Device


Technical Indicators
 
Maximum output current 0~5000A (greater output current is customizable)
output current error is less than 0.5% of set value,
output current adjustment resolution: 1A
Current booster output capacity 50KVA
Temperature monitoring points that can be measured simultaneously 5 units
 
Temperature range 0~200 degree,
measurement error:<0.5 degree, resolution:0.1 degree
DC resistance measurement range 0~200 ohm,
measurement error:0.2% reading value +2D
Time measurement and recording error 0.1ms
Continuous running time more than 24 hours
Current control error 0.5% of the set value
Primary current measurement error 0.5% reading value +5D
CT temperature monitoring points 12
Current transformer body and connector temperature measurement method palladium resistance
Power supply AC220V,45Hz~65Hz
Working environment temperature 0 ~ 50 degrees,
humidity less than 90%

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters