Insulating Oil Breakdown Voltage Testing Device

After-sales Service: Yes
Warranty: 1 Year for Insulating Oil Breakdown Voltage Testi
Type: Insulating Oil Bdv Tester
Load Way: Electronic Load
Loading Method: Dynamic Load
Display: Digital
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDYJ-502
Control
Fully Automatic
Weight
41kg
Power Source
AC220V
Output Voltage
AC 0~80kv
Rate of Voltage Rise
2kv/S±10%
Measuring Precision
3%Rdg+0.3%Fs
Test Times Setting
1-9
Test Standard
IEC60156/ASTM D877/1816
Data Storage
100 Groups
Transport Package
Wooden Case
Specification
71*42*53CM
Trademark
GOLD
Origin
Chongqing
HS Code
9031809090
Production Capacity
300PCS/Month

Product Description

100Kv Insulating Oil BDV Tester for Breakdown Voltage Tester and dielectric strength Tester

Insulating Oil Breakdown Voltage Testing Device
 

Specifications:

1 Output voltage AC 0~80KV/AC 0~100KV
2 Rate of voltage rise 2KV/s±10%
3 Measuring precision 3%RDG+0.3%FS
4 Test times setting  1~9
5 Mixing time setting  0~99 second
6 Waiting time setting 0-9 minute 59second
7 Maximum storage capacity 100 groups of test data
8 Test standards IEC60156
9 Display 256*128 LCD
10 Rated power supply AC 220V±10% 50Hz/60Hz
11 Environment temperatures  0-50°C   
12 Relative humidity ≤80%RH
13 Size    420×380×410mm3
14 Weight 28kg


 

Breakdown voltage testing procedure

To assess the insulating property of dielectric transformer oil, a sample of the transformer oil is taken and its breakdown voltage is measured. The lower the resulting breakdown voltage, the poorer the quality of the transformer oil.

  • The transformer oil is filled in the vessel of the testing device. Two standard-compliant test electrodes with a typical clearance of 2.5 mm are surrounded by the dielectric oil.
  • A test voltage is applied to the electrodes and is continuously increased up to the breakdown voltage with a constant, standard-compliant slew rate of e.g. 2 kV/s.
  • At a certain voltage level breakdown occurs in an electric arc, leading to a collapse of the test voltage.
  • An instant after ignition of the arc, the test voltage is switched off automatically by the testing device. Ultra fast switch off is highly desirable, as the carbonisation due to the electric arc must be limited to keep the additional pollution as low as possible.
  • The transformer oil testing device measures and reports the root mean square value of the breakdown voltage.
  • After the transformer oil test is completed, the insulation oil is stirred automatically and the test sequence is performed repeatedly: typically 5 repetitions, depending on the standard.
  • As a result the breakdown voltage is calculated as mean value of the individual measurements.

Item Pictures
Insulating Oil Breakdown Voltage Testing Device
Insulating Oil Breakdown Voltage Testing Device

Insulating Oil Breakdown Voltage Testing Device
Insulating Oil Breakdown Voltage Testing Device

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters