EN ISO 1182 Non-combustibility Tester for Building Materials
Introduction:
Non-Combustibility Tester measures the non-combustibility and combustibility of uniform building materials and non-uniform building materials of actual elements.
The evaluations (results) are rising temperature in the furnace, basic mass loss, and ignition of the specimen.
It fully satisfies KS F 2271, KS F ISO 1182, and ISO 1182 as international standards at the same time.
This equipment uses a module-type temperature controller to be stable over 60 minutes in the furnace condition of 750±5ºC and meets precise test results.
And another advantage is the automatic up-down specimen movement device for accurate results, as well as a user-friendly process. Thus, it doesn't matter who the test users are.The
RS-232C communication and Data Acquisition Board is able to provide an accurate Interface of test values, so the user can test the whole function and test by PC easily and automatically.
Application:
* Building Materials
* Rail
* IMO
Standards:
ISO 1182
- Reaction to fire test for building material---Non-combustibility test
BS 476-4
- Fire Tests on Building Materials and Structures.. Part 4: Non-Combustibility Test for Materials
BS 476-11
- Fire tests on building materials and structures - Part 11: Method for assessing the heat emission from building materials.
KS F ISO 1182
- Method of non-combustibility test of building products
KS F 2271
- Testing method for the incombustibility of internal material and elements of the building
Feature:
Single Zone Furnace operable at up to 900ºC with the NIKROTHAL Ribbon Heater.
750±5ºC temperature auto control with TPR.
Furnace facilitating maintenance and replacement.
Up/down automatic moving system for correct positioning of the test sample and the user's convenience.
Mirror to observe the ignition quality of the test sample.
RS 232C communication and DAQ Board-adopted interface.
Auto testing by DAQ Board and PC.
Alarm temperature-based over-current shut-off system for the user's safety.
Software (Non-Comb 2005) to print out reports based on exact data results and each standard.
Test Result:
* Mass Loss(g) and Rate(%)
* Ignition Time(s) and Sustained Flaming(s)
* Initial & Maximum Furnace Temperature(ºC)
* Final Furnace Temperature(ºC)
* Maximum Specimen Center Temperature(ºC)
* Final Specimen Center Temperature(ºC)
* Furnace Temperature Rise(ºC)
* Specimen Center & Surface Temperature Rise(ºC)
* Differential Test Result by Standards
(ISO 1182:1990, KS F ISO 1182: 2004, IMO FTPC Pt.1: 1998, KS F 2271: 1998)
Product Image:
Specifications:
Product name | Non-combustibility Tester for Building Materials |
Standard | ISO 1182, BS 476-4, BS 476-11, ASTM E 136 |
Size | 400mm(w) × 400mm(D) × 1,270mm(H) |
Power | 220 V AC, 60 Hz, 10 A |
Weight | about 40kg |
Control unit | 530mm(w) × 270mm(D) × 280mm(H) |
Manual | supplied |
Utilities | Personal Computer and PC Printer |