CE Approved Transformer CT PT Testing Equipment CT PT Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer CT PT Tester
Still deciding? Get samples of US$ 6000/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • CE Approved Transformer CT PT Testing Equipment CT PT Tester
  • CE Approved Transformer CT PT Testing Equipment CT PT Tester
  • CE Approved Transformer CT PT Testing Equipment CT PT Tester
  • CE Approved Transformer CT PT Testing Equipment CT PT Tester
  • CE Approved Transformer CT PT Testing Equipment CT PT Tester
  • CE Approved Transformer CT PT Testing Equipment CT PT Tester
Find Similar Products

Basic Info.

Model NO.
GDVA-405
Item Name
Transformer CT PT Testing Equipment CT PT Tester
Test Standards
IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5
Power Supply
AC220V±10%, 50/60Hz±10%
Voltage Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Power Output
500va
Max. Knee Voltage Measurement
45kv
Current Measurement Range
0~10A
Current Measurement Error
<±0.1%+0.01%Fs
Accuracy
0.02%
Turns Ratio Measurement Range
1~35000
CT Secondary Burden Range
0~160ohm
Transport Package
Plywood Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
2000piece/Month

Product Description

CE Approved Transformer CT PT Testing Equipment CT PT Tester

 

CE Approved Transformer CT PT Testing Equipment CT PT Tester
CE Approved Transformer CT PT Testing Equipment CT PT Tester


 

CE Approved Transformer CT PT Testing Equipment CT PT Tester
CE Approved Transformer CT PT Testing Equipment CT PT Tester

 

Testing Items:

1. Turns ratio testing: Measuring the turns ratio of current transformers (CT) and potential transformers (PT), which is the ratio between the input signal and the output signal.

2. Phase angle testing: Measuring the phase difference between the input signal and the output signal to assess the phase accuracy of CTs and PTs.

3. Vector error testing: Evaluating the difference between the output and theoretical output of CTs and PTs to determine their vector error.

4. Frequency response testing: Checking the response characteristics of CTs and PTs at different frequencies to ensure accuracy and stability across different frequency ranges.

5. Load characteristic testing: Testing the output performance of CTs and PTs under different load conditions to verify their load adaptability and stability.

6. Insulation resistance testing: Evaluating the insulation performance of CTs and PTs, including measurement and assessment of insulation resistance.

7. Zero-sequence current testing: Measuring the response of CTs to zero-sequence currents to assess their capability to detect zero-sequence faults.

8. Withstand voltage testing: Conducting high-voltage withstand tests to verify the insulation strength and tolerance of CTs and PTs.

 

Specifications:

Item Name GDVA-405 CE Approved Transformer CT PT Testing Equipment CT PT Tester
Test standards IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
Power supply  AC220V±10%, 50/60Hz±10%
Voltage output  0.1~180V (AC)
Current output  0.001~5A(RMS)
Power output  500VA
Max.  knee voltage measurement  45KV
Current measurement
 

 
  Range 0~10A (automatically change  range in 0.1/0.4/2/10A)
  Error  <±0.1%+0.01%FS

 

Voltage measurement
 
 Range 0~200V (automatically change range in 1V/10V/70V/200V)
 Error < ±0.1%+0.01%FS
Turns ratio measurement Range
  
1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement   error  ±2min
resolution  0.01min
Winding resistance measurement
    
   
Range 0~8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
Error  < 0.2%RDG+0.02%FS
Maximum resolution :  0.1mΩ
Temperature measurement -50~100 Celsius degree; error<3 Celsius degree
CT Secondary burden Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error  <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
   
  
PT Secondary burden

 
Error 0~80kohm (automatically change range in 800ohm/8kohm/80kohm)
Maximum <0.2%RDG+0.02%FS
resolution  0.1ohm
   
PT ratio measurement
Range

1~35000,

1~10000 error<0.1%, 

10000~35000 error<0.2%

PT ratio error measurement :Typical error<0.05%,  Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window
Memory capacity  >1000 groups test results
Working condition temperature  -10ºC~50ºC; moist ≤90%

CE Approved Transformer CT PT Testing Equipment CT PT Tester
CE Approved Transformer CT PT Testing Equipment CT PT Tester
CE Approved Transformer CT PT Testing Equipment CT PT Tester
CE Approved Transformer CT PT Testing Equipment CT PT Tester