• ISO 5660 Cone Calorimeter Lab Testing for Building Material
  • ISO 5660 Cone Calorimeter Lab Testing for Building Material
  • ISO 5660 Cone Calorimeter Lab Testing for Building Material
  • ISO 5660 Cone Calorimeter Lab Testing for Building Material
  • ISO 5660 Cone Calorimeter Lab Testing for Building Material
  • ISO 5660 Cone Calorimeter Lab Testing for Building Material

ISO 5660 Cone Calorimeter Lab Testing for Building Material

After-sales Service: All Life Technical Supports
Warranty: 12 Months
Customized: Non-Customized
Structure: Desktop
Material: Stainless Steel
Application: Lab
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-ISO5660
Type
Measurement Type
Power Supply
AC 220V, 50/60Hz, 20A
Heat Output
0~100kw/M2
Standards
ISO 5660, ASTM E1354, BS 476-15
Rated Power of Heater
5000W
Display
LCD
Sample Weight
0~2000g
Transport Package
Standard Wooden Case
Specification
White
Trademark
Gold
Origin
China
HS Code
9031809090
Production Capacity
10PCS/Month

Product Description

ISO 5660 Cone Calorimeter For Building Material

 

ISO 5660 Cone Calorimeter Lab Testing for Building Material

Introduction:
Heat release is the core measurement parameter for evaluating the fire characteristics of materials and products.CAN meet all existing standard cone calorimeters (including ISO5660, ASTM E1354, ASTM E1474, ASTM E1740, ASTM F1550, ASTM D6113, NFPA 264, CAN ULC 135 and BS 476 Pt), also CAN buy parts form, this lab if you need any specific test, such as heat release and mass loss, smoke generation, etc., CAN buy the needed parts, first, then gradually add other instruments to the same test chamber, instrument become complete specifications.This flexible characteristic is one of the many advantages of the cone calorimeter.

The test theory of the cone calorimeter is based on the fact that the number of calories burned is proportional to the amount of oxygen burned. Each 1KG of oxygen burned will produce 13.1m /kg of gas. The emission time of the test gas, ignition time, oxygen consumption rate, CO, CO2 generation rate, and gas flow will be measured.
Standards

ISO 5660-1/2/3/4

ASTM E 1354

BS 476 Pt.15

GB/T16172-2007

NFPA 264


Application:
Building Material 

Shipping Material 

Rail

Wire&Cable

Other

Features of Cone Calorimeter

1. Integrated body and 19" analysis rack, 15" touch screen panel type PC for the whole control and automatic testing

2. Conical Heater - is wound in the form of a truncated cone, rated 5000 W at 230 V with a heat output of 100 kW/m2.

3. Facility for testing horizontally or vertically orientated specimens

4. Temperature control by the use of 3-type K thermocouples and a 3-term (PID) temperature controller.

5. Auto Split Shutter automatically opened to transmit radiation to the sample, Automatic Spark Igniter to facilitate measurement of ignition time

6. Specimen Holders - for specimens 100mm x 100mm up to 50mm thick, in the horizontal and vertical orientation.

7. Load Cell - mass measurements are conducted via a strain gauge load cell with an accuracy of 0.1g. Fitted with a quick electronic tare facility and mechanical stops to avoid movement damage, giving stable results, and long life.

8. Exhaust System - manufactured from stainless steel for long life. This comprises, a hood, gas sampling ring probe, exhaust fan (with adjustable flow controls from 0-50g/s, at a resolution of at least 0.1g/s), and an orifice plate flow measurement (thermocouple and differential pressure transducer). Normal operation is at a nominal 24 l/s.

9. Gas feed unit, Model SCC-S, including 1 gas path, condensate monitor, pump, and flow controller with needle valve Peltier cooler and condensate pump. SCC-S can remove water automatically.

10. Smoke Obscuration - measured with a laser system, using photodiodes, and a 0.5 mW Helium-Neon laser, with main and reference (compensating) photodetectors. Supplied with alignment cradle and 0.3, 0.8 neutral density filters for calibration.

11. Medtherm Heat Flux Meter - for setting the irradiance level at the surface of the specimens, the range from 0-100KW/m2.

12. Provide the Self circulation cooling water to cool the heat flux meter, without External tap water.

13. Calibration Burner - to calibrate the rate of heat release measured by the apparatus using methane of 99.5% purity.

14. Methane MFC, to control the flow rate of Methane automatically.

15. OMRON PLC to control all movement such as Split Shutter, Spark Igniter, etc.

16. DAQ(Data Acquisition)Program controllable with the touch screen panel PC

17. Provide 10 units of PMMA samples for comparison testing.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters