Customization: | Available |
---|---|
Warranty: | One Year |
Working Spectral Range: | 190-900nm |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GD-320N Atomic Absorption Spectrophotometer AAS Analyzer
Specifications:
Working spectral range | 190-900nm |
Wavelength accuracy | ≤ ±0.5nm |
Wavelength repeatability | ≤ 0.3nm (single direction) |
Spectrum bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
Resolution | <40% |
Base line stability | ±0.004Abs/30min |
Characteristic concentration of copper | ≤ 0.04mg/ml/1% |
Detection limit of copper | ≤0.008mg/ml |
Background calibration ability | Greater than 30 times |
Standby Interface | RS 232 |
Instrument power supply | 220V, 3A, 50Hz |
Features:
Build-in computer data processing and LCD
Good basic line stability
High precision of measurement
Optical path of high energy
Long-life and anti-corrosive atomization system
Multi-functional analysis mode
Safe and reliable gas path system
Complete set of accessories:
Light-source system
Hollow cathode lamp power supply: with adjustable current Lamp power supply: with fixed current
Optical system
Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm
Flame atomization system
Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.
Signal processing
Absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.
Accessories:
Air compressor;
One piece of Cu hollow cathode lamp;
Gas external pipe;
Acetylene cylinder pressure-reducing valve;
Water knockout gas filter;
Optional Accessories:
GA3202 HGA graphite furnace system
Used to conduct trace and ultra-trace analysis with an absolute sensitivity of 10-10-10-12gram.
5cm long-life titanium burner
The necessary accessory for nitrous oxide-acetylene flame analysis.
Hydride generator (Totally automatic)
Making the characteristic concentration of As, Se, Sb, Bi, Pb, Sn, Te, Ge, In, Tl, Cd and Zn lower than ppb level with cold atomic mercury measurement method.
Hollow cathode lamp
All specifications are available.
Graphite tube
All specifications are available.
Software with I/O port
Printer