Power supply | AC(220±10%)V, 50Hz |
Flash point determination | Range:Ambient to 400ºC Repeatability: ≤8ºC Reproducibility: ≤17ºC Accuracy: 0.1ºC |
Heating rate | Correspond with GB/T3536 and ASTM D92 |
Igniting mod | Electric ignition, Gas flame diameter: 3.2mm~4.8mm |
Ambient temperature | (10 ~ 40)ºC |
Relative humidity | ≤80% |
Maximum power consumption | 500W |
Dimension | 520*380*310mm |
1. The Cleveland Open Cup Flash Point Apparatus should be used in a non-corrosive environment. When replacing the sample, the sample cup must be cleaned.
2. If there is any discrepancy between the instructions and the actual operation, the actual interface prompts and operating procedures of the instrument shall prevail.
3. The detection ring must be kept clean. If there is oil stain, it can be dried with filter paper to avoid affecting the detection sensitivity.
4. When the Cleveland Open Cup Flash Point Apparatus is not in use, it should be placed in an environment with a temperature of 5°C to 40°C, a relative humidity of less than 85%, and an air that does not contain corrosive gases and harmful substances.
5. It is advisable to adjust the height of the detection ring 2-3mm from the edge of the oil cup. When the sample is heated and expands, the detection ring may be immersed in the oil sample. At this time, the detection ring can be adjusted appropriately or the sample volume can be reduced.
6. If the Cleveland Open Cup Flash Point Apparatus is not used for a long time, it should be powered on once in no more than one month for no less than one hour.
Warning: When the Automatic Flash Point Tester fails, the power should be cut off immediately, and after the instrument is completely cooled, please ask professionals to overhaul and troubleshoot before continuing to use it to prevent accidents!
Parameter | GD-3536 | GD-3536-1 | GD-3536A | GD-3536D |
Pictures | ||||
Product name | Cleveland open cup flash point and fire point tester | semi-automatic Cleveland open cup flash point and fire point tester | Automatic cleveland open cup flash point tester | Automatic cleveland open cup flash point and fire point tester |
Temperature range | Ambient temperature~400ºC | Ambient temperature~400ºC | Ambient temperature~400ºC | Ambient temperature~400ºC |
Ignition mode | fire once manually | fire once manually | fire once manually | Automatic |
Temperature display | Thermometer | LCD | Color LCD | Color LCD |
Printing | No | No | Yes | Yes |
Communication port | No | No | No | Yes |
Other function | Manually adjust heating rate | Automatically control temperature and display by LCD | Automatic | Automatic, with RS232 communication port |
Dimension | 350*290*350mm | 340*320*450mm | 410*360*420mm | 520*380*310mm |