Battery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for Transformer No Load Tester
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Battery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss Tester
  • Battery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss Tester
  • Battery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss Tester
  • Battery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss Tester
  • Battery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss Tester
Find Similar Products
  • Overview
  • Application
  • Company Profile
Overview

Basic Info.

Model NO.
GDBR-P
Manual/Auto.
Fully-Automatic
Voltage Range
10V~650V, Accuracy Class 0.2
Current Voltage
100mA~60A, Accuracy Class 0.2
Frequency
40~65Hz, Accuracy Class 0.2
Connect External Transformer
Yes ( Broaden Measure Range )
Power Supply
AC 220V±10%
RMS of Three Phase Voltage
Uab, Ubc, Uca
Average Value of Three Phase AC Voltage
Uab, Ubc, Uca
RMS of Three Phase Current
Ia, Ib, IC
Transport Package
Standard Wooden Case
Specification
20KG
Trademark
GOLD
Origin
China
Production Capacity
1000 Sets / Month

Product Description

Full-automatic Transformer Short Circuit Loss and Capacity Test LoadNo-Load Characteristic Tester

It measures No-load current, No-load loss, short circuit voltage, short circuit loss and capacity of transformer.

Application

 

  1. Measure transformer No-load current, No-load loss, short circuit voltage, short circuit loss and capacity.
  2. Three meters testing methods.
  3. When making three phase transformer No-load, load test, the instrument will judge if the wiring is correct automatically, and shows three phase voltage, current vector diagram.
  4. Finish load test under 1600kVA below distribution transformer full current for single machine. Finish 2500kVA below distribution transformer load test under 1/3 rated current (Under 1/3 rated current, the instrument can be converted to load loss parameters under rated current.)
  5. All test results are corrected automatically. The instrument automatic correction as follows, waveform correction, temperature correction, Non rated voltage correction and non rated current correction. The test results are more accurate.
  6. 320*240 high brightness LCD screen, with brightness adjustment. Touch buttons make the operation more convenient.
  7. Real-time clock, recording test date automatically, suitable for storage and management of test results.
  8. Built-in panel-type thermal printer, fast print test results.
  9. Power down store and browse data (test object set, measurement results, test time) functions. Store up to 500groups test results, data transmission online to PC.
  10. Allows extended range measurement for external voltage transformer and current transformer. Measure test object of any parameters.
  • Specifications:

1. Test items

  • RMS of three phase voltage: Uab,Ubc,Uca.
  • Average value of three phase AC voltage: Uab,Ubc,Uca.
  • RMS of three phase current: Ia,Ib,Ic.
  • Percentage of No-load loss and No-load current: Po,Io%.
  • Load loss, impedance voltage percentage, short circuit impedance: Pt,ekt,Zt.
  • Load loss, impedance voltage percentage and short circuit impedance at any specified temperature.
  • Transformer actual capacity and judged capacity.

2. Main technical parameters

  • Current measurement range: 100mA-60A,accuracy:class 0.2.
  • Voltage measurement range: 10V-650V,accuracy:class 0.2.
  • External transformer can broaden the measurement range of instrument.
  • Frequency measurement range: 40-65Hz, accuracy:class 0.2.
  • Power input: AC220V± 10%.
Full-automatic Transformer Short Circuit Loss and Capacity Test Load No-Load Characteristic Tester
PARAMETER GDBR-P
Manual/auto. Fully-automatic
Test items RMS of three phase voltage: Uab, Ubc, Uca
Average value of three phase AC voltage: Uab, Ubc, Uca
RMS of three phase current: Ia, Ib, Ic
Percentage of no-load loss and no-load current: Po, Io%
Load loss, impedance voltage percentage, short circuit impedance: Pt, Ekt, Zt
Load loss, impedance voltage percentage and short circuit impedance at any specified temperature
Transformer actual capacity and judged capacity
Voltage range 10V~650V, accuracy class 0.2
Current voltage 100mA~60A, accuracy class 0.2
Frequency 40~65Hz, accuracy class 0.2
Connect external transformer Yes ( Broaden measure range )
Power supply AC 220V±10%
  • Product Show:
Battery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss TesterBattery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss TesterBattery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss Tester
Company Profile

Battery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss TesterBattery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss TesterBattery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss TesterBattery Charging Transformer Short Circuit Loss and Capacity Test Load/No-Load Loss Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier