IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1

Product Details
Customization: Available
After-sales Service: Technical Support,Online Service
Warranty: 1 Year
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1
  • IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1
  • IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1
  • IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1
  • IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1
  • IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1
Find Similar Products
  • Overview
  • Product Description
  • Standard
  • Product Parameters
  • Features
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
GD-IEC 60332
Standard
IEC 60332-1-1.2.3,En 50086-1
Operating Voltag
AC220 V Addition and Subtraction 10V 50Hz
Ambient Temperature
Room Temperature ~ 40 Celsius
Gas Pressure
0.1MPa
Gas Purity
Propane> 95%; Compressed Air
Timing Accuracy
0.1s
Model
Gd-IEC60332
Size
600(W)*450(D)*1250(H)mm
Power
AC 220V, 50/60Hz, 3A
Transport Package
Wooden Box
Trademark
GOLD
Origin
Chongqing China(Mainland)
Production Capacity
100PCS/Month

Product Description

Product Description

IEC 60332-1-1.2.3 Single cable and wire Flame Spread Flammability EN 50086-1

IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1

Introduction:
Single Cable Flame Propagation Tester meets the standards IEC 60332-1-1/2/3 in the provisions of technical indicators and requirements. Single cable combustion Tester is used to test the flame retardant property of the cable's insulating layer under abnormal conditions such as overheat and overcurrent.It can be used in vertical cable or fiber flame spread test,also can be test the state of flaming droplets during combustion.
Standard

IEC 60332-1-1/2: Testing of electric and optical cables under fire conditions, vertical, spread test of single insulated wire and cable, 1kw premixed flame method
EN 50086-1-1994: Specification for piping systems for electrical installations
GB/T 18380.11,12-2008 (replaced version GB/T 12666.2/GBT 18380.1-2001)

Users' Experiences:
1.This tester designed with high intelligence and easy to operate.
2. With professional industrial design, beautiful appearance and reasonable layout.
3. This equipment is precision, security, and stability.
4. With microcomputer control system, intelligent testing process,no need to manually time.
5. Orrosion-resistant stainless steel test cabinet.

Product Parameters
Product name IEC 60332-1 Flammability Tester for Single Cable
Operating voltage AC220 V ± 10V 50HZ
Ambient temperature room temperature ~ 40 ºC
Gas Pressure 0.1MPa
Gas purity Propane> 95%; compressed air
Timing Accuracy 0.1s
Size 600(W)×450(D)×1250(H)mm
Power AC 220V, 50/60Hz, 3A
Weight 60kg
Manual Provide
Features

1. High level of intelligence, simple operation
2. Professional industrial design, beautiful and generous
3. Equipment precise, safe, and stable
4. Microcomputer control system, intelligent testing process; no need for manual timing or related operations
5. Stainless steel corrosion-resistant housing

Advantages Of  Our Product:
1. Touch screen intelligent control system with both Chinese and English operating interface (optional).
2. Automatic ignition, timing, and data storage system
3. The integrated design of the test section and control section allows for easy on-site installation and debugging
4. The stainless steel box has an internal cavity height of 1200mm, width of 300mm, and depth of 450mm
5. Two stainless steel rods for securely fixing single wire or optical cable samples with perforations and bolts
6. The premixed burner has an inner diameter of ¢12±0.5mm and a length of approximately 100mm. A 1KW standard mixed burner provides precise testing of the fire source
7. Flame application time and burning time can be adjusted within the range of 0 to 99 minutes and 99 seconds. The test process is automatically controlled
8. Imported needle valve for precise adjustment of flame height, with a blue flame height of 50mm~60mm as per standard requirements, total height of 170mm~190mm
9. Needle valve controls gas flow rate
10. Equipped with a flame height caliper
11. Includes a gas flow meter and pressure regulator; automatic ignition
12. The spray lamp angle is adjustable from 45° to 0°
13. Flame verification device is optional.

Packaging & Shipping

wooden packing for IEC 60332-1-1.2.3 Single cable and wire Flame Spread Flammability EN 50086-1
IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1

Company Profile

IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1

IEC 60332-1-1.2.3 Single Cable and Wire Flame Spread Flammability En 50086-1Our service:
Pre-sale Service:
Inquiry will be replied within 24 hours. 
Welcome to visit our factory. 
Technical datas and operation manual sent for evaluation.
After-sale Service:
Training how to instal the machine, training how to use the machine at our factory.
Engineers available to service machinery overseas at customers' cost.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier