Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
  • Audited Supplier
  • 20 yrs

Contact Supplier

Product Highlights

  • Lifetime Technical Support: Provides lifetime technical support for all purchased equipment.
  • High Sensitivity Detection: Detects metal elements with limits as low as Ppm or even Ppb (0.001ppm).
  • 8-Element Simultaneous Analysis: Features 8 lamp turrets for automatic preheating and simultaneous soil element testing.
  • Automated Wavelength Scanning: Fully automated wavelength scanning and peak searching capabilities.
  • Advanced Data Storage: Super strong database with over 500 data self-storage and cut-off storage functions.
  • Comprehensive Safety Protection: Includes warning and automatic safety protection for gas leakage, under voltage, and abnormal flameout.
  • ISO9001 Certified: Manufactured and tested in compliance with ISO9001 international quality standards.
  • Flexible Atomizer Control: PC-controlled system allows flexible selection of flame and graphite furnace atomizers.

Product Images of Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas pictures & photos
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas pictures & photos
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas pictures & photos
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas pictures & photos
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas pictures & photos
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas pictures & photos
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
  • Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
    Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
  • Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
    Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
  • Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
    Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
  • Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
    Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
  • Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
    Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
  • Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
    Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

Find Similar Products

Product Description

Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

Working principle

* Atomic absorption spectroscopy is a measurement method based on the absorption by ground-state atoms of characteristic wavelengths.
* Normally, atoms are in the ground state. For each element, the energy for their atoms to transit from the ground state to the exited state is known and called characteristic spectral lines. For atomic absorption spectroscopy, a hollow cathode lamp (HCL) is used as the light source to emit the light of the wavelength characteristic of an element. Then the light passes through the atom vapor which absorbs the light of the characteristic wavelength. The concentration of atom concentration of the element is calculated based on the absorption of the light.
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

After a beam with intensity of I0 passes through the media with atomic concentration of C, the intensity is decreased to I, by following the Lambert-Beer law.
A = lg(I0 /I) = KCL

A: Absorbance
I0: Incident ray intensity of characteristic spectral lines
I: Emergent ray intensity of characteristic spectral lines
k: Absorbance factor
L: Flame distance passed by ray of characteristic spectral lines
C: Atomic concentration
The equation indicates that the absorbance and atomic concentration is in a linear relationship in certain circumstances.

Main Technical Features

Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term. 
3. Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp
4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions
5. Fully automated wavelength scanning and peak searching
6.Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout
7. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called
8. Measuring method: flame absorption method and emission method
9. Result printing: parameter printing, data result printing and diagram printing

Product Parameters

v Wavelength range:190 - 900nm
v Spectral bandwidth:Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
v Accuracy of the wavelength:±0.15nm
v Receptivity of the wavelength: ≤0.04nm
v Base line stability:≤0.002A/30min (Cu)
v Characteristic viscosity:0.02μg/ml/1% (Cu)
v Checking limit:0.004μg/ml (Cu)
v Preciseness:0.5%
v Grating:1800 lines/mm
v Inflamer:All-metal titanium burner
v Atomizer:Effective glass atomizer
v Lamp stand:Eight lamps 
v D2 background correction ability:When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
v Size and weight:700mm×550mm×450mm  75Kg
v Power source:220V±22V  AC
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

Flame system:
v Acetylene air burner:100mm
v Nitrous oxide acetylene flame head:50mm
v Ignition dynamic baseline drift:≤0.006A/30min
v (Cu) Characteristic viscosity:≤0.025μg/ml/1%
v Related standard deviation of the accuracy:≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
v Safety system:Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner. 

Graphite furnace:
v The highest temperature:3000ºC
v The largest temperature rising speed:≥2000ºC/S
v Characteristic quantity:Cd≤0.5×10-12g  Cu≤0.5×10-11g
v Accuracy:Cu≤3%  Cd≤3%
v Size and weight:550mm×450mm×300mm 65Kg
v Safety system:Over current protection 
v Low air pressure alarm / protection 
v Low cooling water flow alarm/protection
Power source and power:220V±22V AC 7000W

 

Detailed Photos

Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

Packaging & Shipping

Our product packaging has been proven over the long term and we usually have plywood boxes or cartons with trays. We will arrange the appropriate packaging according to the weight and size of the goods. Of course, you can also choose the packaging form.
Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

Contact us

Welcome to contact us talk about details if you are interested in Atomic Absorption Spectrometer Price Simulately Soil Elements Analyzer Aas

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR229508". Items marked "verified" are certified.

Watch Video
Watch Video
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.
Chongqing Gold Mechanical & Electrical Equipment Co., Ltd.

About Our Factory & Business Background

Address
#2501, China Resources Building, Xiejiawan, Jiulongpo District, Chongqing, 400050, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, CPT
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Chongqing, Shanghai

Our Production Capability & Technical Expertise

Main Products
Oil Purifier, Fire Testing Equipment, Petroleum Products Testing Equipment, Electrical Testing Equipment, Transformer Test Set, Oil Test Kit, Fire Retardant Test, Cone Calorimeter, Bdv Tester, Flash Point Tester

Our Industry Experience & Global Business Record

Export Year
2008-05-03
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the warranty period?
We provide a 1-year warranty for this Atomic Absorption Spectrometer.
Can the device detect multiple elements simultaneously?
Yes, it supports 8-element simultaneous testing with automatic preheating of hollow cathode lamps.
What is the detection limit for metal elements?
The detection limit can reach Ppm or even Ppb (0.001ppm) depending on the element.
Is the product customizable?
No, this model is Non-Customized.
What is the wavelength range of the spectrometer?
The wavelength range is 190 - 900nm.
Does the system include data storage capabilities?
Yes, it has a database capable of storing over 500 data points with cut-off storage functions.
What safety features are included?
It features automatic gas cutoff for low pressure, power off, flameout, and burner mismatch.
What are the lead times for delivery?
Both peak season and off-season lead times are within 15 workdays.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now