Customization: | Available |
---|---|
After-sales Service: | Life Time Support Service |
Warranty: | 1 Year for Power Quality Analyzer |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Real-time waveform display (4-channel voltage/4-channel current) Voltage and current true RMS Voltage DC component Current and voltage peak values Current and voltage half-cycle RMS max/min values Phase diagram display Measurement of harmonics in each phase up to the 50th harmonic Bar graph display of harmonic content for each phase of current and voltage Total Harmonic Distortion (THD) Active/reactive/apparent power values and total values for each phase Active/reactive/apparent power value and total value for each phase Transformer K-factor Power factor (PF) and COSφ Displacement power factor (DPF) Short-term voltage flicker Three-phase unbalance (voltage and current) |
Power supply | Rechargeable lithium battery pack 9.6V, external charger. 40-70Hz |
Power Consumption | Current consumption 490mA, battery fully charged about 8 hours of continuous operation. |
Display mode | LCD colour screen, 640*480dots, 5.6 inch, display area 116*88mm. |
Jaw size | 008B pointed small-shaped current clamp: 7.5* 13mm; 040B round mouth-shaped current clamp: 35*40mm; 068B round mouth-shaped current clamp: 68*68mm; 300F Flexible coil current sensor (with integrator): Φ300mm. |
Current | 008B current clamp: 10mA~10.0A; 040B current clamp: 0.10A~100A; 068B current clamp: 1.0A~1000A; 300F flexible coil current sensor (with integrator) 10A~3000A |
Number of channels | 4-channel voltage, 4-channel current. Line voltage 1.0V~2000V. Phase voltage 1.0V~1000V. |
Electric quantity parameters | W, VA, Var, PF, DPF, cosφ, tanφ |
Energy parameters | Wh, Varh, Vah |
Number of transient recordings | 150 |
Screenshot capacity | 60 |
Instrument size | 240*170*68 mm |
Weight | Main unit: 1.6kg (with battery); 008B pointed small-shaped current clamp: 170g × 4; 040B round mouth-shaped current clamp: 190g × 4; 068B Round-ported current clamp: 510g×4; 300F Flexible coil current sensor (with integrator): 330g × 4; Test cable and power adapter: 900g; Total weight: approx. 9.2kg (including packaging). |
Voltage test lead | 3m |
Current clamp line length | 2m |
Test voltage input impedance | 1MΩ |
Voltage withstand | The instrument line and the shell withstand 3700V/50Hz sine wave AC voltage for 1 minute. |
Insulation | ≥ 10MΩ between the instrument line and the sheath enclosure. |
Suitable for safety regulations | IEC 61010 1000V Cat III / 600V CAT IV, IEC 61010-031, IEC 61326, pollution class 2 |