  • Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
  • Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
  • Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
  • Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
  • Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
  • Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
Find Similar Products

Basic Info.

Model NO.
GD-3200
Type
Karl Fischer Moisture Meter
Analysis Method
Chemical Analysis
Display
LED
Application
Chemicals
Portable
Portable
Physical Analysis Type
Weightlessness Method
Chemical Analysis Type
Karl Fischer Method
Operating Mode
Touch Screen
Heating Mode
Standard Heating
Off Mode
Manual
Test Standard
ASTM D6304. ASTM D1533. ASTM E1064. ASTM E203
Electrolytic Current
400mA Maximum
Measurement Range
3 - 9999.9 Ug 
Instrument Resolution Ratio
0.1 Ug
Titrator Display
7 Inch High Definition True Color Touch Screen
Printing
Wide Line Thermal Printing
Power Supply
AC220V, 50Hz
Power
100W
Transport Package
Wooden Case
Specification
390*70*220mm
Trademark
GOLD
Origin
Made in China
HS Code
9031809090
Production Capacity
200PCS Per Month

Product Description

Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
Introduction:
* The Automatic karl fischer titrator determines low concentrations of water in a wide range of liquid, gas and powder samples. The Coulometric Karl Fisher Titrator is used for assessing water content in petroleum and petrochemical products including oils, gasolines, solvents, and fluids as well as other products such as pharmaceuticals and cosmetics.
* The Coulometric Karl Fischer titration is the ideal method to determine low moisture and water contents in samples (0.001 to 1% water content).

* Karl Fischer Coulometric titrator for measuring trace moisture content in the sample accurately, this method has widely used with the advantages of high accuracy, low test cost. The instrument is based on Karl Fischer Coulometric titrator principle, accurate determination of liquids, solids, gases trace moisture .
Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
Product Parameter:
1. Electrolytic current: 400mA maximum
2. Measurement range: 3 - 9999.9 ug 
3. Instrument resolution ratio: 0.1 ug
4. Accuracy: 3mcg water ±20%   10mcg water±10%   100mcg water±1%  more than 100mcg ±0.5% (sample introduction error is not included)
5. Display: 7 inch high definition true color touch screen (1024*600)
6. Printing: wide line thermal printing
7. Power supply: AC220V±10% 50Hz±5%
8. Power: 100W
9. Environment temperature: 0 - 50ºC
10. Environment humidity: ≤85%
11. Volume: 390×270×220
12. Weight: 6kg
Work Principle:
Karl Flscher reagent reacts with water below:
12 + SO2 + 3C5H5N + CH3OH + H2O = 2C5H5N·HI + C5H5N·HSO4CH3
The reagent solution used is prepared by mixing simple substance iodine, I- and SO2-containing methanol, etc. The measurement is based on the conductibility of the equilibrium system consisting of simple substance iodine andI-. The following reactions proceed alternately on two electrodes when the current is imposed on them:
2I--2e→I2
I2 + 2e→2I-
There is an excess of I- in the solution, but the I- concentration change does not greatly affect the solution conductibility. The change of simple substance iodine concentration within a range will cause an effective change of the solution conductibility. We select the range in which the higher simple substance iodine concentration leads to the bigger change of solution conductibility, and measure the value of the current intensity generated by the voltage at both ends of the platinum electrode immersed in the solution. The current intensity reflects the solution conductibility. A sample is injected to the electrolyte. The water in the sample reacts. The tester can detect the iodine change in the reaction, while the tester can calculate the iodine consumption from the electric quantity consumed when the same amount of iodine is electrolyzed out. The mass of the water to be tested is directly indicated on the LED display. This tester has an electrolytic current autocontrol system, which can automatically control the electrolytic current according to the water content of the sample. The maximum electrolytic current is up to 400 mA. During electrolysis, the water content gradually reduces, and the electrolysis rate reduced proportionally till an equilibrium point. The corresponding control loop of end point of titration starts, and the tester stops of measurement accumulation. This system ensures high analysis precision, sensitivity and speed. In addition, some interference factors unavoidably exist during measurement. For example, blank current is generated in the titration cell because of the water immersed in air. However, this tester has the memory and subtracts blank current, so the mass displayed on LED display is the real water content of the sample.


Features:
1.Strong environmental adaptability, precise, accurate and stable measurement results
2.Built-in multiple test methods, easier testing
3.High reliability
4.Simple operation
5.The display content is rich, and the measurement process is clear at a glance
6.Multiple test result units are optional, suitable for different samples
7.Navigational operation, more intuitive and convenient
8.Rich extension interface
Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer
Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer

Contact us!
1 With competitive price
2 Premium quality with CE & ISO certification
3 Strong product OEM & ODM customization capability
4 Promise production & on-time delivery
5 Perfect after-sales service, free product accessories
6 15 years of experience in R&D and production
Welcome to contact us talk about details if you are interested in Automatic ASTM D1533 D6304 Karl Fischer Kf Coulometric Titrator Moisture Analyzer.If you want to know more information,Don't hesitation, welcome your inquiry!Price can be negotiated !

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier