• IEC60331 Electrical Impact and Spray Tester for Cable and Wire
  • IEC60331 Electrical Impact and Spray Tester for Cable and Wire
  • IEC60331 Electrical Impact and Spray Tester for Cable and Wire
  • IEC60331 Electrical Impact and Spray Tester for Cable and Wire
  • IEC60331 Electrical Impact and Spray Tester for Cable and Wire
  • IEC60331 Electrical Impact and Spray Tester for Cable and Wire

IEC60331 Electrical Impact and Spray Tester for Cable and Wire

After-sales Service: All Life Technical Supports
Warranty: 12 Months
Item Name: IEC60331 Electrical Impact and Spray Tester
Reference Standards: Gbt19216/ IEC60331 / BS 6387
Power: AC 380V 3-Phase, 50/60Hz, 30A
Weight: About 300kg
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-IEC60331
Manual
Supplied
Utilities
Propane Gas, Compressed Air, Personal Computer, Du
Material
Stainless Steel
Application
Wire and Cable
Overseas Training
Provide
Transport Package
Standard Export Woodn Case
Specification
1, 600mm(W)× 850mm(D)× 1, 900mm(H)
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
10 Units Per Month

Product Description

IEC60331 Electrical Impact and Spray Tester For Cable and Wire
IEC60331 Electrical Impact and Spray Tester for Cable and Wire

IEC60331 Electrical Impact and Spray Tester for Cable and Wire

Introduction:
IEC60331 Electrical Impact and Spray Tester For Cable and Wire are in accordance with IEC 60331-12 and BS 6387 standards.

IEC60331 Electrical Impact and Spray Tester For Cable and Wire is used in testing conditions when the basic flame temperature is at least 830ºC and to test the cable exposed to flame and mechanical shock that needs to maintain the circuit integrity.
You can test cables A, B, C, and D retardant properties.


Application:
Wire & Cable

Standards:
1, BS 6387: Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions
2, IEC 60331: Test for electric cables under fire conditions - Circuit integrity
3, IEC 60331 Part 12: Apparatus - Fire with shock at a flame temperature of at least 830ºC
4, IEC 60331 Part 31: Procedures and requirements for fire with shock - Cables of rated voltage up to and including 0.6/1kV
5, IEC 60331-1: Test method for fire with shock at a temperature of at least 830ºC for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm
6, IEC 60331-2: Test method for fire with shock at a temperature of at least 830ºC for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm
7, IEC 60331-3:Test method for fire with shock at a temperature of at least 830ºC for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure.


Main Features:
Control cabinet parameters:
1, With dual flow meters and pressure regulators.
2, Automatic control of the testing process.
3, Intelligent detection function, when a short circuit in the sample during the test, automatic alarm and turn off the heat source.
4, Display: touch screen display temperature curve
5, Timer: 0 to 9 hours 99 minutes 99 seconds
6, Control Box Size: 650mm(D)*400mm(W)*1200mm(H)
7, Load: 0 ~ 600V test voltage is adjustable;
8, Load current range: 0.1 ~ 3A, test current can be adjusted standards, but more than 3A is protected;
9, Load capacity should be able to ensure the test current approaches 3A can still ensure the test to continue testing. Also, apply to spray test and hammering test load requirement.


Fire test equipment requirements:
1, The burner nozzle length is 500mm, width is 15mm, there are three holes on the nozzle opening troubleshooting, pore radius of 1.32 mm pitch is 3.2 mm. Equipped with Venturi mixer;
2, Installation and testing of the cable ladder fastened to the supporting steel chassis; the testing process can be adjusted on both sides of the vertical component testing ladder depending on cable size requirements (test stand length: 1200mm, height: 60mm, total weight: 18 ± 1kg);
3, Metal ring inside diameter of about: 150 mm;
4, With a temperature measuring device (diameter less than 2mm K-type thermocouple, from the flame ports 75mm);
5, The front burner torch from the bottom of the box less than 200MM, 500MM, and from the tank wall at least;
6, According to the test grade, the flame temperature is adjustable: 600 ~ 1000 ° (A grade 650°, B grade 750°, C, D grade 950°);
7, The horizontal distance between the center of the burner test cable is 40-60MM, and the vertical axis from the longitudinal axis of the specimen cable burner is 100-120MM;
8, Provide standards of five inner diameters of about 150 mm from metal rings, metal ring distance can be freely adjusted to facilitate sample fixed hold;
9, Stainless steel sample tray, load 30kg.


Thump test device:
Hammering test device components:
1, Stainless steel bracket impact structure; box painting processing;
2, Independent motor control box hit;
3, the Thump cone is ¢ 25, and the length is 600mm;
4, Pounding free fall from an angle of 60°to thump;
5, The motor drove rod hammer striking as standard required period;
6, Hammering cycle (time):  30 ± 2S / time;
7, Total time test: 0 ~ 99999S;
8, The ribbon burner (as sprinkler test) (shared with refractory combustion test bench);
9, A test temperature of 600 ~ 1000°(A grade 650°, B grade 750°, C, D grade 950°);
10, Thermocouple diameter is less than ¢ 2mm. (Shared with refractory combustion test bench);
11, Each phase of cable through 0.25A of the current test.


Water spray test equipment (optional):
1, Use propane or natural gas burner, using an integrated long 400mm ribbon burner;
2, Combustion test temperature 650 ± 40 °;
3, With a diameter of not more than ¢ 2 of the thermocouple;
4, Sprinkler water pressure is 250 ~ 350Kpa, to test the water is about 0.25 ~ 0.3L / S*m2
Test length about 400mm;
5, Test the cable when powered by an isolation transformer, and connected to the 3A fuse or circuit breaker, as well as each phase of the cable off lights indication.


Test Results:
1,  Cable test description 
2,  Manufacturer 
3,  Voltage Test 
4,  Cable Bending Radius 
5,  Applied Performance Requirements 
6,  Test criterion or related standards 
7,  Flame application time 
8,  Voltage maintenance (ex. Fuse fails) 
9,  Rupture of the conductor (ex. Lamp blackout)


Specifications:
1, Test Apparatus(Test Ladder) Size:1,200mm(L)*600mm(H);
2, AC Motor: 4 pole / 3 P / 220VAC / 60 Hz / 1,550 RPM / 9.40 kg-cm;
3, Heat Source: Ribbon-type Propane Gas Burner; 
4, Burner Dimension: 500mm(L)*10mm(W), hole space : 3.2mm; 
5, Auto Ignition system; 
6, Mass Flow Controller:
--Gas : 15 SLPM / Signal Output : 0 ~ 5V / Accuracy : ±1 % fo F.S 
--Air  : 180 SLPM / Signal Output : 0 ~ 5V / Accuracy : ±1 % fo F.S 
Electric Control: Transformer & Slidacs : 3 Phase 3 wire, 100~1,000V 
7, DAQ System: 
--16 channel Analog Input / Output, 200ks/s 
--16 channel Digital Input / Output 
8, Control Rack:730mm(W)*650(W)*1,400mm(H)/ 19"Rack / Each Assembly Connector; 
9, Size: 1,600mm(W)×850mm(D)×1,900mm(H);
10, Exhaust: Minimum 15m3/min;
11, Utilities: Propane Gas, Compressed Air, Personal Computer, Dust Collector;

Product name IEC60331 Electrical Impact and Spray Tester for Cable and Wire
Power AC 380V 3-phase, 50/60Hz, 30A
Weight about 300kg
Size 1,600(W)*850(D)*1,900(H)mm
Manual Supply
warranty 12 months
test chamber Size (W) 2,500 x (D) 1,800 x (H) 1,600 mm

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters