• Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment
  • Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment
  • Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment
  • Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment
  • Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment
  • Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment

Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Power Factor Meter Tan Delta Tester
Type: Transformer Power Factor Meter Tan Delta Tester
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Samples:
US$ 5000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Introduction
  • Features
  • Specification
Overview

Basic Info.

Model NO.
GDGS
Display
Digital
Control
Manual Control
Weight
30kg
Power Source
AC220V
Product Name
Transformer Tan Delta and Power Factor Tester
Application Field
High Voltage Electrical Equipments in Power Plants
Operating Type
Fully Automatic
Capacitor Value
1%Rgd+5PF
Tangent Delta
1%Rdg+0.04%
Maximum Current
200mA
Testing Frequency
45Hz/55Hz
Environment Temperature
0-50°c
Transport Package
Wooden Case
Specification
550*490*580mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200PCS/Month Tan Delta Tester

Product Description


Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment

Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment

Introduction

 

Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment
Tan Delta (TD) - also referred to as Dissipation Factor or sometime even Power Factor - is an excellent diagnostic test that provides an indication as to the quality of the dielectric insulation used in electrical apparatus. By analyzing the dielectric losses in theinsulation, the GDGS Series of Tan Delta test instruments provide the testing engineer with a versatile high voltage diagnostic system that is suitable for testing MV cable such as XLPE, EPR, PE and PILC. In addition, other electrical apparatus such as capacitors, transformers and large rotating machines can also be diagnosed.

Features

Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment is used to measure dissipation factor (PF) in heavy interference site such as power plants or power substations. It can also be used in laboratory for high accurate test.

 

The Tan Delta tester is whole in one designed: including precision digital bridge, power unit, reference capacitor (CN), step-up transformer and other electronic circuits. It's also using frequency shift technology, FFT (Fast Fourier Transform algorithm) and digital filtering. When started, it's running automatically and then outputs the results on LCD display and prints the results automatically.
 

Specification

Measurement Range Capacitance value: 3pF ~ 60000 pF/10kV 60pF ~ 1μF/0.5kV
Dissipation range: 0 ~ 100% unlimited, resolution: 0.001%,
 The Automatic identification of capacitance,
inductance, resistance test products
Maximum error
 
Capacitance accuracy: ± (1.0% × reading ± 1 pF)
Dissipation accuracy: ± (1.0% × reading ± 0.04%)
Resolution
 
Capacitance resolution: min. 0.001 pF
Resolution of dielectric loss: minimum resolution 0.001
Test current range 10μA~5A
Internal high voltage Setting voltage range: 0.5 to 10kV,
maximum output current: 200mA
Test frequency 50Hz single frequency, 45/55Hz automatic double frequency conversion
Power supply 180V ~ 270VAC ,50Hz / 60Hz ± 1%
 
Operating temperature ambient temperature: 0 ~ 40 ºC;
ambient humidity: ≤ 90% RH, no condensation
Size and weight 550*490*580mm,28kg

 

Item Show

Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment

Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment
Power Factor Meter Transformer Tan Delta Test Set Dielectric Loss Test Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters