Automatic Surface Tension Measurement Tensiometer by Du Nouy Ring Method

Product Details
Customization: Available
After-sales Service: on-Line and off-Line Service
Warranty: 2 Years
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Automatic Surface Tension Measurement Tensiometer by Du Nouy Ring Method
  • Automatic Surface Tension Measurement Tensiometer by Du Nouy Ring Method
  • Automatic Surface Tension Measurement Tensiometer by Du Nouy Ring Method
  • Automatic Surface Tension Measurement Tensiometer by Du Nouy Ring Method
  • Automatic Surface Tension Measurement Tensiometer by Du Nouy Ring Method
  • Automatic Surface Tension Measurement Tensiometer by Du Nouy Ring Method
Find Similar Products

Basic Info.

Model NO.
GD-6541A
Measurement Range
5~99.9mn/M
Features
Automatic, Reliable, Repeatable and Simple Operati
Electronic Tensiometer Test Method
Ring Method, Meet GB/T6541 Standard
Communication Function
RS232 Host
Price Level
Low
Warranty or Guarantee
1 Year
OEM Supply
Yes
Packing Size
45*38*38cm
Gross Weight
17kg
Service
Engineers Available to Service Machinery Overseas
Transport Package
Packed in Plywood
Specification
Standard
Trademark
GOLD
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
10000 Sets/Month

Product Description

Automatic Surface Tension Measurement Tensiometer by Du Nouy Ring Method



Introduction:
The Du nouy ring method is a traditional test method, which takes about 70 years. Using a platinum wire with a diameter of 0.37 mm made into a ring with a circumference of 60 mm. During the test, the platinum ring is immersed in the liquid surface (or two non-mixed interfaces) for 2-3 mm, and then the platinum ring is slowly lifted upward, and a film is formed between the ring and the liquid surface. The membrane has a pull-down force on the platinum ring, measuring the maximum force applied to the ring during the entire platinum ring lift process, and then converting it to a true surface (interface) tension value.

The Du nouy ring Tensiometer is based on Platinum Ring Method Principle to achieve accurate measurement of liquid surface tension value. The instrument integrates a number of advanced technologies, widely used in chemical, petroleum, electric power, scientific research, railways and other industries.


Main Features:
1.  Full-automatic measuring the sample tension value using a powerful new generation of microprocessor.
2 . 10-inch 65K (resolution 800*600) color touch LCD display, Chinese and English prompt menu operation.
3 . The surface of the appearance is treated by electrostatic spray, which is corrosion-resistant and easy to clean.
4 . With 25ºC automatic temperature compensation function, the effect of temperature on the measured tension value is solved.
5 . The instrument automatically zeros, automatically measures, calculates, displays experimental results, and has a power-down storage function.
6 . The lifting platform of the instrument is automatically raised and lowered, stable, low noise and accurate.
7.  The use of a magnetic tank closed sensor with equal-interval multi-point calibration improves the repeatability and reproducibility of measurement results.


Reference Standards:

1. GB/T6541-1986 Petroleum products -- Mineral oils-Determination of interfacial tension of oil against Water by Ring Method.
2. ISO 6295-1983 Petroleum products -- Mineral oils-Determination of interfacial tension of oil against water-Ring method.
3. JB/T 9388-2015 Interface tensiometers -- Technical specification.
4. ISO1409-1995 Plastics/rubber -- Polymer dispersions and rubber latices (natural and synthesis)-Determination of surface tension by the ring method.
5. SH/T1156-2014 Determination of synthetic latex surface tension.
6. GB/T5549-1990 Surface active agents -- Determination of surface tension by drawing up liquid films.
7. ISO 304-1985 Surface active agents -- Determination of surface tension by drawing up liquid films.
8. ISO 4311-1979 Anionic and non-ionic surface active agents -- Determination of the critical micellization concentration -- Method by measuring surface tension with a plate, stirrup or ring.
9. GB/T 22237-2008 Surface active agents--Determination of surface tension.
10. GB/T 18396-2001 Natural latex--Ring method for measuring surface tension.
11. ISO14090-82, ASTM D1417, EN14370, ZB2025-93, GB2960-82, etc.
 

Main Specifications:
 
Display method 10 inch 65K (resolution 800*600) color touch LCD display
Measurement method Principle of platinum ring method
Platinum ring radius R9.55 platinum wire r0.3
Measuring range 0-400mN/m
Sensitivity 0.01mN/m
Accuracy ±0.01mN/m
Self-checking function failure automatic diagnosis
Temperature compensation auto temperature compensation
Power consumption <40W
Dimensions 440mm*190mm*350mm
Service environment Temperature 10ºC-40ºC, humidity<80%
Power supply AC220V±10% 50HZ±2.5HZ
Weight About 7.5kg