Breakdown Voltage Tester Oil Dielectric Strength Test Set

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Oil Bdv Tester
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Breakdown Voltage Tester Oil Dielectric Strength Test Set
  • Breakdown Voltage Tester Oil Dielectric Strength Test Set
  • Breakdown Voltage Tester Oil Dielectric Strength Test Set
  • Breakdown Voltage Tester Oil Dielectric Strength Test Set
  • Breakdown Voltage Tester Oil Dielectric Strength Test Set
  • Breakdown Voltage Tester Oil Dielectric Strength Test Set
Find Similar Products

Basic Info.

Model NO.
GDYJ-501
Type
Transformer Oil Breakdown Voltage Tester
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
256*128 LCD
Control
Fully Automatic
Weight
48kg
Power Source
AC220V
Product Name
Breakdown Voltage Oil Dielectric Strength Tester
Test Standards
IEC60156
Output Voltage
AC 0~80kv/100kv
Rate of Voltage Rise
2kv/S±10%
Measuring Precision
3%Rdg+0.3%Fs
Test Times Setting
1-9
Data Storage
100 Groups
Transport Package
Wooden Case
Specification
420*380*410mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
300PCS/Month

Product Description

Breakdown Voltage Tester Oil Dielectric Strength Test Set
Breakdown Voltage Tester Oil Dielectric Strength Test Set

GDYJ-501 breakdown voltage tester is a device used to measure the voltage value of insulating materials or liquids when they break down under high voltage. Routine tests of transformer oil include breakdown voltage measurement, dielectric loss factor measurement, water content, gas content determination and dissolved gas gas chromatography analysis. The breakdown voltage test is to verify the maximum voltage capacity that transformer oil can withstand, that is, its dielectric strength.

Product Parameter

1 Output voltage AC 0~80KV/AC 0~100KV
2 Rate of voltage rise 2KV/s±10%
3 Measuring precision 3%RDG+0.3%FS
4 Test times setting  1~9
5 Mixing time setting  0~99 second
6 Waiting time setting 0-9 minute 59second
7 Maximum storage capacity 100 groups of test data
8 Test standards IEC60156
9 Display 256*128 LCD
10 Rated power supply AC 220V±10% 50Hz/60Hz
11 Environment temperatures  0-50°C   
12 Relative humidity ≤80%RH
13 Size    62*54*55cm
14 Weight 48kg


Product Features

1. High stability and long service life
2. The testing process fully meets the requirements of IEC60156 standards
3. Each part of the test process can be set, high precision testing
4.Provide PC application software to upload test data and produce Word test report


Why do we need transformer oil testing?

1. Breakdown voltage (BDV) test: Evaluates the insulation strength of insulating oil. Generally requires> 30KV, otherwise the oil needs to be replaced or treated.
2.Flash point test: Evaluates the fire resistance of the oil. It must be higher than the highest operating temperature of the insulating oil to qualify, usually> 135°C. 
3.Conductivity test: Evaluates the impurity concentration in the insulating oil. Excessively high conductivity will accelerate oil aging and insulation degradation.
4.Pressure Volume Temperature Index (PVT) test: Comprehensively evaluates the insulation performance of insulating oil and is used to determine the degree of oil quality change.
5.Moisture test: Evaluates the water content in the insulating oil. Too much moisture accelerates aging and insulation degradation of the insulating oil.
6.Acid value test: Evaluates the chemical stability of the insulating oil. An increasing acid value indicates that chemical changes have occurred in the oil.
7.Odor test: Detects changes in the odor of insulating oil through human olfaction to determine the degree of oil quality change.
8. Color test: Uses a colorimeter to detect the depth of darkening of the insulating oil color and indirectly determine the degree of oil quality change.

Purpose of breakdown voltage measurement test
The breakdown voltage of transformer oil is an important indicator to measure the degree of contamination of transformer oil by water and suspended impurities: the lower the breakdown voltage of the oil, the worse the overall insulation performance of the transformer, which directly affects the safe operation of the transformer; therefore, strict testing must be carried out and the breakdown voltage of transformer oil must be controlled within different ranges.

Different Models to Choose from

Breakdown Voltage Tester Oil Dielectric Strength Test SetOuter Packaging
Breakdown Voltage Tester Oil Dielectric Strength Test Set
Breakdown Voltage Tester Oil Dielectric Strength Test Set


About Us
Breakdown Voltage Tester Oil Dielectric Strength Test Set

Breakdown Voltage Tester Oil Dielectric Strength Test Set
Our Workship
Breakdown Voltage Tester Oil Dielectric Strength Test Set

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier