Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for Oil Immersed Transformer AC DC Hipot
Still deciding? Get samples of US$ 3500/Piece
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv
  • Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv
  • Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv
  • Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv
  • Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv
  • Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv
Find Similar Products

Basic Info.

Model NO.
GDJ
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Product Name
Oil Immersed Transformer AC DC Hipot Test Set
Transformer Type
Oil Immersed
Output Voltage
AC50kv DC70kv
Capacity
3kVA,5kVA,10kVA,15kVA,20kVA and So on
Application
Withstand Voltage Test and Leakage Current Test
Test Standard
IEC60076
Transport Package
Plywood Case
Specification
as different requirements
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kV-300kV

Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv

Introduction

GDJ Series Oil Immersed Test Transformer AC DC Hipot Tester for Cable Withstand Voltage Testing is applied in power system for insulation test of high voltage equipment.

The typical application of the HIPOT tester is as follow:

  • Power Transformer AC high voltage withstand test

  • Circuit Breaker AC high voltage withstand test

  • High voltage motors high voltage withstand test

  • Voltage/current transformer high voltage withstand test

  • High voltage power source for calibration of high voltage meter

 

Model Selection Table

  • Please confirm the right model before order. The main parameters include input voltage, maximum output voltage and capacity.

  • The parameters in this table are response for HV transformer only and we will install the main control box according to the capacity and input voltage of the model you order.

Capacity
KVA
GDJZ-50 Series GDJZ-100 Series GDJZ-150 Series
AC DC AC DC AC DC
3kVA 50KV 70KV        
5kVA 50KV 70KV 100KV 140KV    
10kVA 50KV 70KV 100KV 140KV 150kV 210KV
15kVA 50KV 70KV 100KV 140KV 150kV 210KV
20kVA 50KV 70KV 100KV 140KV 150kV 210KV
25kVA 50KV 70KV 100KV 140KV 150kV 210KV
30kVA 50KV 70KV 100KV 140KV 150kV 210KV
50kVA 50KV 70KV 100KV 140KV 150kV 210KV


Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv

Notice

  • If the maximum voltage is less than 100kv we will offer dry HV transformer for the tester, otherwise we will offer oil HV transformer for the tester;

  • The capacity and maximum voltage output could be customized according to the requirements of customer if you can not find the right one in this table;

  • The weight listed in the table is HV transformer only it does not include the weight of main control box. Please confirm the total weight of the tester with our sales engineer before order;

    FAQ

    1. Q: What is the language? After sale service,the Warranty? 
        A:English version or as your requirement.Warranty : 1 year. 

    2.  Q: Does it output AC or DC or AC&DC?  
         A: For model GDJZ, it's AC and DC output. For model GDJ, It's AC output.

    3. Q: Whether does it have battery or liquid ? Convinent to delivery?  
         A: Some models have insulation oil, no battey, which does not influence the delivery.  

    4. Q: Where is it used? 
        A: Testing dielectric strength of High-voltage electrical equipment, electrical components, insulation material. For example,cable, high-tension switch etc.  

    5.  Q: What types of testing equipment?What's the difference?    
         A: There are dry, oil-immersed and inflatable,three types. Differences as follow:
            Dry: light weight, volume light, can rewind.
            Inflatable: interrupter resistance, and light weight.
            Oil-immersed: capacity, cheap, easy maintenance, mainstream products.



    Product Details

    Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv

                                      Oil Type Transformer

    Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv

                                      Controller for Large Capacity


Digital High Voltage Oil Immersed Transformer AC DC Hipot Test Set 50kv-300kv

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier