High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support,Online Service
Warranty: 1 Year for CT PT Tester
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester
  • High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester
  • High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester
  • High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester
  • High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester
  • High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester
Find Similar Products
  • Overview
  • Product Parameters
Overview

Basic Info.

Model NO.
GDVA-405
Product Name
CT PT Tester
Usage
CT PT Testing Equipment
Test Standards
IEC60044-1/2/5/6,IEC61869
Power Output
0.1~180V (AC)
Current Output
0.001~5A(RMS)
Maximum Knee Voltage
45kv
Power Supply
220V 50Hz
Turn Ratio Measurement
1-30000
Transport Package
Wooden Case
Specification
49*36*19cm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
200PCS/Month CT PT Analyzer

Product Description

High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester
High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester

GDVA-405 Automatic CT PT Tester can test protection and metering CT/PT (220V~500KV,capacity ≥2.5VA), suitable for laboratory and field testing.
This source generates AC of 0-180V and 0.001-5A current to sample CT.

The accuracy is 0.02%(Typical), 0.1%(Guarantee).

Product Parameters

 

GDVA-405 CT PT Analyzer
1 Test standards IEC60044-1, IEC60044-6, IEC60044-2,IEC60044-5,IEC61869, C57.13
2 Power supply AC220V±10%,50Hz/60Hz±10%
3 Power output 0.1~125V (AC)
4 Current output 0.001~5A(RMS)
5 Power output 300VA
6 Max. knee voltage measurement 45kv
7 Current measurement range 0~10A (automatically change range in 0.1/0.4/2/10A)
8 Current measurement error <±0.1%+0.01%FS
9 Voltage measurement range 0~200 V (automatically change range in 1V/10V/70V/200V)
10 Voltage measurement error < ±0.1%+0.01%FS
11 Turns ratio measurement range 1~30000;
1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2%
12 Phase measurement error:±2min,resolution:0.01min
13 Coil resistance measurement Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ
14 Temperature measurement -50~100 Celsius degree, error<3 Celsius degree
15 CT Secondary burden Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)
Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm
16 PT Secondary burden Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)
Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm
17 PT ratio measurement Range: 1~30000, 1~5000 error<0.2% 5000~30000 error<0.5%
18 Saved data groups >1000groups
19 Work condition Temperature:-10ºC-50ºC, moist:≤90%
20 Size 49*36*19cm
21 Weight 15kg

More Details for High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester

High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester
High Precision Transformer Analyzer CT PT Testing Equipment CT PT Tester


What are some common issues or faults that can be detected during CT/PT analyzer tests?

During CT/PT analyzer tests, various common issues or faults in current transformers (CTs) and potential transformers (PTs) can be detected. Here are some examples:

1. Incorrect turns ratio: The CT/PT analyzer can identify if the turns ratio of the transformer is outside the specified range. A mismatch in turns ratio can lead to inaccurate current or voltage measurements.

2. Polarity reversal: The analyzer can detect if the polarity of the CT or PT is reversed. Polarity reversal can result in incorrect phase angles and erroneous measurements.

3. Saturation: CTs and PTs have a saturation point beyond which their accuracy is compromised. The analyzer can determine if the transformer saturates at expected voltage levels, ensuring it operates within the linear range.

4. Burden mismatch: The burden impedance connected to the secondary side of the CT or PT should match the specified values. The analyzer can identify if the burden impedance is outside the acceptable range, which can affect accuracy.

5. Insulation issues: By performing insulation resistance tests, the analyzer can reveal any insulation degradation or faults in the windings of the CT or PT. This helps detect potential insulation breakdown or safety risks.

6. Accuracy deviations: The analyzer compares the output of the CT or PT under test with a reference standard to evaluate its accuracy. Any significant deviations from the expected values indicate calibration or performance issues.

7. Phase angle discrepancies: The analyzer measures and compares the phase angle between the primary and secondary sides of the transformer. Significant phase angle variations can indicate problems with the winding or core.

By detecting these issues and faults during CT/PT analyzer tests, corrective actions can be taken, such as recalibration, repair, or replacement of the faulty transformers. Regular testing helps ensure the transformers' accuracy, reliability, and adherence to industry standards.