Customization: | Available |
---|---|
After-sales Service: | Lifetime Technical Support,Online Service |
Warranty: | 1 Year for CT PT Analyzer |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Application:
Tests for current transformer:
Excitation curve and parameters test
Turns ratio test
Ratio and phase error test
Polarity mark check
Coil resistance measurement
Secondary loop burden measurement
Error line curve test for protection CT
Transient CT parameters test
CT nameplate guess
Saturation hysteresis loop curve measurement
Applications for CT analyzer:
CT nameplate check
CT parameters check in work burden
CT transient parameters analysis
CT ratio and phase error calibration
No. |
Item Name |
GDVA-404 China Made Current Transformer and Voltage Transformer CT PT Analyzer |
1 |
Test standards |
IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 |
2 |
Power supply |
AC220V±10%,50Hz/60Hz±10% |
3 |
Power output |
0.1~125V (AC) |
4 |
Current output |
0.001~5A(RMS) |
5 |
Power output |
300VA |
6 |
Max. knee voltage measurement |
45kv |
7 |
Current measurement range |
0~10A (automatically change range in 0.1/0.4/2/10A) |
8 |
Current measurement error |
<±0.1%+0.01%FS |
9 |
Voltage measurement range |
0~200 V (automatically change range in 1V/10V/70V/200V) |
10 |
Voltage measurement error |
< ±0.1%+0.01%FS |
11 |
Turns ratio measurement range |
1~30000; 1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2% |
12 |
Phase measurement |
error: ±2min,resolution:0.01min |
13 |
Coil resistance measurement |
Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm) Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ |
14 |
Temperature measurement |
-50~100 Celsius degree, error<3 Celsius degree |
15 |
CT Secondary burden |
Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm) Error<0.2%RDG+0.02%FS Maximum resolution 0.001ohm |
16 |
PT Secondary burden |
Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm) Error<0.2%RDG+0.02%FS Maximum resolution: 0.1ohm |
17 |
PT ratio measurement |
Range: 1~30000 1~5000 error<0.2% 5000~30000 error<0.5% |
18 |
Saved data groups |
>1000groups |
19 |
Work condition |
Temperature: -10ºC-50ºC, moist: ≤90% |
20 |
Size |
485mm*356mm*183mm |
21 |
Weight |
<15Kg |
Pre-sale Service:
After-sale Service:
"For most of the products, delivery lead time is 10 days after the order is confirmed; For some customized products, please check with the sales person."
"For total amount below USD3,000.0, payment term is 100% T/T as deposit; For total amount above USD3,000.0, payment term is 30% T/T as deposit, the balance before delivery; The payment term is also negotiable."