• China Made Three Phase Portable Power Quality Analyzer
  • China Made Three Phase Portable Power Quality Analyzer
  • China Made Three Phase Portable Power Quality Analyzer
  • China Made Three Phase Portable Power Quality Analyzer
  • China Made Three Phase Portable Power Quality Analyzer
  • China Made Three Phase Portable Power Quality Analyzer

China Made Three Phase Portable Power Quality Analyzer

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Portable Power Quality Analyzer
Display: Digital
Installation: Direct Connected
Usage: Multi-Functional Energy Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Maximum Demand Meter
Electric Equipment: Three-phase Four-wire
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-5000
Theory
Electronic Meter
Power Meter Connection
Terminal
Type
Power Meter
Certification
CE
Customized
Customized
Item Name
Three Phase Portable Power Quality Analyzer
Application
Measure Power Quality of Electrical Device
Features
Multi-Functional, Intelligent, Easy to Use
Power Supply
Batteries
Display Mode
LCD Color Screen
Data Storage
150 Groups
Communication
USB
Packing Size
400*270*270mm
Gross Weight
8kg
Transport Package
Packed in Carton Box
Specification
240mm*170mm*68mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9031809090
Production Capacity
10000 Sets/Month

Product Description

China Made Three Phase Portable Power Quality Analyzer
 
China Made Three Phase Portable Power Quality Analyzer
 
China Made Three Phase Portable Power Quality Analyzer
China Made Three Phase Portable Power Quality Analyzer
China Made Three Phase Portable Power Quality Analyzer




Technical Specification:

1.1. Base condition and working condition  
 
Influence factor Test item Base condition Working condition
Environment temperature All parameters (23±2)°C -10°C~ 40°C
Relative humidity All parameters 40%~ 60% <80%
Phase-to-neutral voltage All parameters (100±1%)V 1.0V~ 1000V
Phase-to-phase voltage True RMS phase-to-phase voltage (200±1%)V 1.0V~ 2000V
Current True RMS current (5±1%)A 10mA~ 1000A
Network frequency All parameters 50Hz±0.1Hz 40Hz~ 70Hz
Phase shift  Active power and active energy Cosφ=1 Cosφ: 0.2~ 1.0
Reactive power and reactive energy Sinφ=1 Sinφ: 0.2~ 1.0
Harmonic All parameters <0.1% 0.0%~ 100%
Voltage unbalance All parameters <10% 0.0%~ 100%
Working voltage of device All parameters DC9.8V±0.1V DC9.5V~ 10.5V
External electric field, 
magnetic field
All parameters Should be avoided
Test position Measured related parameters of current Tested wire at the center of clamp.


1.2. General specification
 
Power supply Rechargeable lithium-ion battery pack 9.6V, backup charger.
Battery indicator Battery symbol       shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.
Power consumption Current consumption of normal test 490 mA, continuous working for 8 hours.
Display mode LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.
Size of clamp 008 small sharp current clamp: 7.5mm×13mm;
040 circle current clamp: 35mm×40mm;
068 circle current clamp: 68mm×68mm.
Instrument dimensions L×W×H: 240mm×170mm×68 mm.
Number of channels 4U/4I.
Phase-to phase voltage 1.0V~2000V.
Phase-to-neutral voltage 1.0V~1000V.
Current 008 current clamp: 10mA~10.0A;
040 current clamp: 0.10A~100A;
068 current clamp: 1.0A~1000A;
Optional current transformer: instrument input current 1mA~500mA.
Frequency 40Hz~70Hz.
Parameters of electricity W, VA, Var, PF, DPF, cosφ, tanφ.
Energy parameters Wh, Varh, Vah.
Harmonic Order 0~50.
Total harmonic distortion Order 0~50, each phase.
Expert mode Yes.
Number of Transient records 150 sets.
Voltage flicker Yes.
Starting current mode Yes, 100 seconds.
3 phases unbalance Yes.
Record 300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
Min/Max recorded value Measurement of maximum and minimum values over a period of time.
Alarm 40 different types of parameter selections, 12,800 sets alarm logs.
Peak Yes.
Phasor diagram display Automatically.
Capacity of snapshots 60.
Menu language English/Chinese.
Communication USB.
Automatic switching off When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
Backlight function Yes, suitable for use at night and dark place.
Weight Host: 1.6kg (with battery).
008 small sharp current clamp: 170g×4;
040 circle current clamp: 190g×4;
068 circle current clamp: 510g×4;
Test wires and power adapter: 900g;
Total weight: about 10.5kg (with packaging).
Length of voltage test wire 3m.
Length of current sensor wire 2m.
Working temperature and humidity -10°C~40°C; below 80%Rh.
Storage environment -10°C~60°C; below 70%Rh.
Input impedance Input impedance of test voltage: 1MΩ.
Withstand voltage Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
Insulation Between instrument wiring and shell ≥10MΩ.
Structure Double insulation, with insulation vibration-proof sheath.
Safely rules IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
Packing Size 400× 270×270(mm)  (L ×W ×H)
Weight 8Kg
 
China Made Three Phase Portable Power Quality Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters