After-sales Service: | All Life Technical Supports |
---|---|
Warranty: | 12months |
Item Name: | ISO 9705 Room Corner Burning Testing Equipment |
Reference Standards: | Gbt25207;ISO 9705;ASTM E 603 |
Model Number: | Gd9705 |
Power: | 220V AC, 60Hz, 10A |
Customization: |
---|
Suppliers with verified business licenses
(RCT), as ISO's evaluation of the fire-resistance performance of building materials, measures heat release rate (H.R.R), smoke generation rage, oxygen consumption, CO, CO2 production and so on.
As the basis of ISO 9705(ISO 9705 Room Corner Burning Testing Equipment For Building Materials), RCT is the test that reproduces local fire conditions by flame combustion in the small room of building structure and measures fire movement and combustion diffusion in the building structure.
-Measuring Section.
- Bi-Directional Probes & DPT (Differential Pressure Transducer) for measuring flow rate in the duct.
- Thermocouples for measuring temperature in the duct.
- Sampling Port & Analyzer (O2, CO2, CO) for collecting and analyzing generated gases.
- The laser used to measure the amount of smoke.
- Rapid cooling system (Cold Trap) used to remove moisture for analyzing pure gas.
- Pressure (DPT) Line for measuring flow rate and Gas Sampling for gas collection.
- Filtering System for delivering reliable gases with no impurities into the analyzer.
- Module for data collection (Data Logger, DAQ System).
- PC for auto control and data monitoring.
- MFC(Mass Flow Controller) for automatically controlling the flow of propane gas.
- Auto Valve System for opening/closing propane gas.
- Ignition System for auto-ignition.
specification
Product name | ISO 9705 Room Corner Burning Testing Equipment For Building Materials |
control way | computer |
Power | 220VAC 3A 50Hz |
Weight | 700KG |
Model | GD9705 |
Company Information:
Suppliers with verified business licenses