• Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
  • Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
  • Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
  • Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
  • Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
  • Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser

Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser

After-sales Service: Lifetime Technical Support
Warranty: 1year
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Portable Liquid Particle Counter
Maxcapacity: <1000KN
Samples:
US$ 5500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-LPC-P3
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Touch Screen
Control
Manual Control
Weight
8.5kg
Power Source
AC220V
Oil Cylinder Position
Top
Product Name
Full Automatic Portable Liquid Particle Counter
Application
Aviation, Electric Power, Petroleum, Chemical Indu
Keyword
Liquid Particle Counter
Power Supply
AC220V 50Hz
Measurement Range
0.8um~100um
Battery Continuous Working Time
6~8hrs
Battery Capcity
5200mAh
Pressure Range
Low Pressure
Light Sources
Semiconductor Laser
Data Output
Built-in Printer and R232 Interface
Transport Package
Wooden Case
Specification
410*320*165 mm
Trademark
Gold
Origin
China
Production Capacity
100 Piece/Pieces Per Month

Product Description

Portable Liquid (Oil) Particle Counter For Laboratory Analysis Oil Particule Counter Laser

Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
Technical Indicator:
Light Sources Semiconductor laser Sensitivity 0.1 μm
Sampling volume 0.2-6000mL Sampling accuracy Better than ± 1%
Sampling speed 5-80mL/min Cleaning speed 5-80mL/min
Counting error <±5% Resolution <10%
Repeatability RSD < 2% Limiting Recombination Error 12000-40000 particles/mL
Working temperature -20ºC-60ºC Online detection interval time Arbitrary setting
Power supply AC100-240V, 50/60Hz Battery capacity 5200mAh
Battery Run Time 6-8 hours Overall Dimension 410*320*165mm
Weight 8.5kg Temperature of test sample 0ºC-80ºC
Particle size range 0.8-600μm (calibrated to ACFTD calibration 1-100μm or ISO MTD calibration 4-70μm(c))
Customized detection channels 16 channels, any particle size
Off-line viscosity <100cSt (optional pneumatic chamber for high viscosity)
Pressure range Low pressure 0~0.6Mpa, high pressure up to 42Mpa (optional pressure reducing valve)
Instrument Structure
COM1:Reserved Port.
USB:USB disk interface. Insert the U disk to store(or export) the test data in the U disk.
COM2:PC serial port. Through this serial port, the instrument is connected to the upper computer and the operate it with the computer software.
AC:External 220V power supply input
POWER:Instrument power switch
IN:Oil sample input port
OUT:Oil sample export port
Printer:Print out test data.
Touch panel: used for touch control and display to realize the operation of the instrument.

 
Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
Operation Cautions
a) After starting up, the instrument should be warmed up for 10 minutes before testing.
b) To ensure the accuracy of the test, appropriate solvents (such as petroleum ether) should be used to clean the pipeline and injection slit before the test.
c) At the end of the test and when the inspection is replaced, a suitable solvent (e.g. petroleum ether) must be used for cleaning operation,Ensure that the instrument pipeline is clean before shutting down or carrying out the next test.
d) The instrument should be kept away from high voltage, high frequency and electromagnetic interference sources.
e) When the battery is insufficient, it should be charged in time, and when it is not used for a long time, it should be charged regularly to ensure the life of the battery.

 

 

Comparison of key parameters of portable particle counter
Parameter LPC-P2 LPC-P3 LPC-P5 LPC-P50 LPC-P6
Dimensions 310×305×135mm 410×320×165mm 275×220×107mm 365×295×170mm 420×326×182mm
 
Weight 7.5Kg 8.5Kg 2.5Kg 5.5Kg 8.5Kg
Screen 5.6 inch 5.6 inch 3.5 inch 10.2 inch 7 inch
Power source
 
Bidirectional piston pump Bidirectional piston pump Metering pump
 
Metering Pumps
 
Bidirectional piston pumps
Battery Built-in 5200mAh Built-in 5200mAh External, optional Built-in 8000mAh, no battery indicator Built-in 5200mAh
Repeatability ≤2% ≤2% ≤5% ≤5% ≤2%
Customized Channels 16 channels 16 channels No Customization No Customization 64 channels
System Software
 
Multi-level account password login, editable test results
 
Multi-level account password login, editable test results
 
    Multi-level account password login, editable test results
 
Moisture Viscosity Temperature Function Optional
 
Optional
 
Moisture temperature is standard. Viscosity is not optional Moisture temperature is standard. Viscosity is not optional Optional
 
Computer function Connectable to computer Connectable to computer     Connectable to computer

Operation Interface
Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser
Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser

Our Service
1. Professional manufacturer with 10 Years
2. Have both high quality products and high quality service
3. Strict inspection system. Every order must be checked by the professional inspection department during production and before shipping
4. Product is safety, we have certificate CE, FCC, ROHS
5. Sample, We can offer sample to you if you need. Pls no hesitate to tell me
6. Speed delivery time. Around 10-15 days, based on your quantity and designs
7. Shipping: by sea or air, as customers request
8. Warranty one year
Portable Liquid (Oil) Particle Counter for Laboratory Analysis Oil Particle Counter Laser

Contact Information:
If you have interested in Portable Liquid (Oil) Particle Counter For Laboratory Analysis Oil Particule Counter Laser , please feel free to contact with me:
Chongqing Gold Mechanical&Electrical Equipment Co., Ltd
 website: chinainstrument.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters