• ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath
  • ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath
  • ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath
  • ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath
  • ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath
  • ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath

ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath

After-sales Service: Lifetime Technical Support
Warranty: 1 Year
Max Diameter of Workpiece: 500mm
Mass Scope of Workpiece: <900kg
Type: Petroleum Products Solidifying Point & Cold Filter
Maxcapacity: ASTM D88
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-0620B
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Under
Temperature Control Mode
Point Controlled by Digital Temperature Controlle
Temperature Control Arrange
0.00ºC~100.00ºC
Temperature Control Accuracy
±0.01ºC
Pressure Range
300mmhg±0.5mmhg
Measurement Range
About 18 PA.S~580000PA.S
Test Samples
4 Samples
Operation Interface
Touch-Type Colored LCD
Net Weight
32.5kg(No Water in Bath)
Transport Package
Wooden Case
Specification
590mm*430mm*630mm
Trademark
GOLD
Origin
China
Production Capacity
200units/Month

Product Description

ASTM D2171
Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath

ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath
ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath

 

Introduction: 
This instrument is made as per standards T 0620_2000 Dynamic Viscosity Test for Bitumen (Vacuum Capillary Method) in JTG E20_2011 Specification and Test Methods for Bitumen and Bituminous Mixture for Highway Engineering and SH/T0557_1998 
Test method for Viscosity of Petroleum Asphalt (Capillary Method) . 

Application and scope of use:
1. The instrument is used to determine the dynamic viscosity of thick asphalts with vacuum capillary tubes. The test temperature is 60ºC and vacuum degree is 300mmHg unless otherwise specified. 
2. This instrument is also suitable to test other materials which vacuum degree is 300mmHg(40Kpa) and viscosity is 0.0036~20.000Pa.s with the vacuum capillary tube method at 60ºC test temperature.


Main technical specifications:
1. It has a data base for coefficients of capillary viscometers. It can save 10 groups of coefficients at most. Operator can callout the data whenever need.
2. It adopts high accuracy pressure sensor. The vacuum degree can be kept at 300mmHg±0.5mmHg. It can be shown on the 
screen clearly.
3. The system will ignore the results which timing is less than 60s and enter next measurement step. The system will calculate the viscosity automatically for the results which timing is beyond 60s.
4. Operator can choose and set automatic calculation of average value and bias percentage for 2~4 parallel tests at will.The calculation can be done for several times to remove the unsatisfied results for operator. The test report can be printed. 


Specifications:
1. Temperature control mode:    Point controlled by digital temperature controller.
2. Temperature control arrange:    0.00ºC~100.00ºC
3. Temperature control accuracy:    ±0.01ºC
4. Pressure range:   300mmHg±0.5mmHg
5. Timing mode:    4 built-in timer. Can do timing for 4 capillary viscometers
6. Timing range:    0.0s~99999.9s(27.7h); Bias ≤0.02%
7. Measurement range:  About 18 Pa.s~580000Pa.s
8. Test samples:       4 samples
9. Operation interface:  Touch-type colored LCD
10. Power supply:      AC(220±10%)V , 50Hz
11. Ambient temperature:   5ºC~50ºC
12. Relative humidity:     ≤85%
13. Overall dimension:    590mm×430mm×630mm
14. Net weight:          32.5kg(no water in bath)


Instrument structure:

ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath
1.Exhaust port: 4 ports from left to right. Connect them to the capillary tubes from 1# to 4# successively with the configured white rubber pipes.
2. Capillary tubes:Vacuum capillary tubes. Radius for each one is 0.25mm, 0.5mm,1.0mm,2.0mm(2 pcs),4.0mm.
Four pieces of capillary tubes can be placed in the bath at a time. The number from left to right is1# ~ 4#.
3. Cover of heater and stirring shaft: Heater and stirring vane are placed in the cover.
4. Capillary tube holder:It is used to hold the capillary tube.
5. Timing control buttons:From left to right:1# ~ 4#. It controls the air exhausting time from1# to 4# separately.(Please read details in Chapter VI.8 test operation)
6. Display:Light touch colored LCD. Operator can control the test by operating the touch key on the screen. Meanwhile it shows parameters.
7. Microprinter. It print the test result after test finished.
8. Temperature controller: It controls the temperature in the bath. Precision is ±0.01ºC.

Product Details:

ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath
ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary Bath


What service can our company provide you?
Pre-sale Service:
1. The professional sales team will reply to the inquiry in real time;
2. Customize suitable solutions according to the needs of different customers;
3. Provide product technical parameters/operation manuals and evaluation reports, etc.;
After-sale Service:
1.From the date of purchase within one year instrument, is a product quality problem free repair replacement, lifetime supply of maintenance and technical services.
2.Technical Support
(1)Our technical team supports our customers at all time with our long experience, expert advice and the unlimited spirit and always be for providing the best customer service.
(2)Training how to install the machine,you can arrange your engineer to our company to get free training.
(3)If necessary, we can also arrange our engineer to your company for training and commissioning at your cost.
3.The instrument has found anomalies or malfunctions please contact us to arrange the most convenient treatment options.


Packaging &Shipping:
Our product packaging has been proven over the long term and we usually have plywood boxes or wooden case with trays. We will arrange the appropriate packaging according to the weight and size of the goods. Of course, you can also choose the packaging form.

Packaging The product will be packed in wooden case, and also can be packed by others ways as your request.
Both neutral and customized packing are available.
Shipping We can ship the goods to you by international express,such as DHL, UPS, TNT and so on.
And you can choose the appropriate way based on your timeline and budget. Besides, you can choose to use your own shipping agent.
ASTM D2171 Laboratory Bitumen Dynamic Viscometer of Viscosity Test Vacuum Capillary BathContact Us:
Welcome to contact us talk about details if you are interested in Azimuth Thruster, Marine Propellers, Bow thruster etc. Propulsion system.If you want to know more information,Don't hesitation, welcome your inquiry!Price can be negotiated! 
Website: chinainstrument.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now