Gbt16429 Minimum Ignition Temperature Tester

Standard: IEC 61241-2-1
Application: Measure Heat Release of Building Materials
Bomb Capacity: 300 Ml
Maximum Power: 0.5kw
Warranty: 1 Year
Furnace Temperature: Room Temperature ~ 800c
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-61241
Size
500X300X450 mm
Power
230V / 50Hz or 110V / 60Hz.
OEM Service
Available
Transport Package
Plywood Case
Trademark
Gold
Origin
China
HS Code
9031809090
Production Capacity
100 Sets/Month

Product Description

      GBT16429 Minimum Ignition Temperature Tester
Products:

The minimum ignition temperature tester is a way of testing the sensitivity of the ignition that the dust cloud in the heated environment. When a lot of dust is exposed in heating the air and  the air temperature is high enough, it may lead to spontaneous combustion. This instrument can test the minimum ignition temperature of combustible dust cloud.
Standard:
IEC 61241-2-1:1994,EN 50281-2-1:1999,
GB / T 16429 "minimum ignition temperature of a dust cloud testing methods" .

Technical parameters:
1. The tester is carried on the in Godbert-Greenwald furnace.
2. The  heating furnace is consist of the vertical  quartz tubes . The hole is at the bottom of the tube.
3. Furnace operating temperature range: room temperature ~ 800 ºC
4.The operating temperature can rise to 1000 ºC to clean the the test chamber .
5. Temperature accuracy: ± 1% (higher than 500 ºC), ± 3% (lower than 300 ºC).
6. The  pressure of the dispersion air chamber: 0 ~ 1 bar
7. The pressure accuracy of the air  storage device : ± 5%
8. Size : 500X300X450 mm.
9. Power: 230v / 50Hz or 110v / 60Hz.

Test Process
The minimum ignition temperature tester is carried on the in Godbert-Greenwald furnace. The heating furnace is consist of the vertical quartz tubes.The hole is at the bottom of the tube.the glass observing room is connected with sample fixing device at the top of the quartz tubes. The compressed air from the tank blows the dust  into the heating furnace and the sample fixing device ,and then exposed into the glass observing room and the quartz tubes .the heating furnace is located on the holder . And you can observe the ignition appearance from the bottom of the furnace. The test begins from the 500ºC. If you observe the ignition appearance ,you shall decrease the temperature at the 10ºC,until the ignition does not appear.
Results description
When the ignition occurs , the lowest temperature is recorded as the minimum ignition temperature of the dust cloud .
The minimum ignition temperature of the test data information is used to determine whether the surface temperature of the equipment  can cause the  automatic fire  of the exposed dust . It is an important standard to evaluate the selection of the equipment at the condition of the dusty environment . When using the  minimum ignition temperature testing data ,you shall leave a safety limit for the small-scale test .

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters