Oil Particle Counter Particle Size Distribution Analyzer Particle Counters Suppliers
Introduction:
1. The Oil Particle Counter is an advanced instrument designed to accurately detect the size and number of particles in liquids. It is based on the principle of light resistance (shading method) and provides highly reliable and accurate results.
2. The Portable Particle Counter is a versatile tool that is perfect for on-site particle detection in various liquids. It is compact, lightweight, and easy to carry, making it ideal for use in a variety of industrial settings.
3. With its advanced technology and cutting-edge features, the Oil Particle Counter is the perfect solution for monitoring the cleanliness of hydraulic fluids, gear oils, turbine oils, and other types of liquids commonly used in industrial applications.
4. The Portable Particle Counter is highly effective in detecting and measuring the size and number of particles in liquids, making it an essential tool for quality control, research, and development, and environmental monitoring applications.
5. Whether you need to detect particles in oil, water, or other liquids, the Oil Particle Counter and Portable Particle Counter are the perfect tools for the job. They are both user-friendly, reliable, and designed to deliver high-performance results every time.
Light Sources |
Semiconductor laser |
Sensitivity |
0.1 μm |
Sampling volume |
0.2-6000mL |
Sampling accuracy |
Better than ± 1% |
Sampling speed |
5-80mL/min |
Cleaning speed |
5-80mL/min |
Counting error |
<±5% |
Resolution |
<10% |
Repeatability |
RSD < 2% |
Limiting Recombination Error |
12000-40000 particles/mL |
Working temperature |
-20ºC-60ºC |
Online detection interval time |
Arbitrary setting |
Power supply |
AC100-240V, 50/60Hz |
Battery capacity |
5200mAh |
Battery Run Time |
6-8 hours |
Overall Dimension |
410*320*165mm |
Weight |
8.5kg |
Temperature of test sample |
0ºC-80ºC |
Particle size range |
0.8-600μm (calibrated to ACFTD calibration 1-100μm or ISO MTD calibration 4-70μm(c)) |
Customized detection channels |
16 channels, any particle size |
Off-line viscosity |
<100cSt (optional pneumatic chamber for high viscosity) |
Pressure range |
Low pressure 0~0.6Mpa, high pressure up to 42Mpa (optional pressure reducing valve) |
1)Measurement Range:0.8um~100um
2)Number of channel:64channel,size can be set free(in the range of selected curve)
3)Sampling volume:≥0.2ml
4)Sampling speed:5~80ml/min
5)Resolution:<10%
6)Coincidence deviation limit:10000 particles /ml
7)Pressure Range:Low Pressure:0~6bar
High Pressure:3~420bar
8)Data Storage:1000 Group
9)Viscosity detection range:0~50cSt(optional)
10)Water activity:0~1aw(optional)
11)Water content:0~360ppm(optional)
12)Power Supply:AC220V±10%;50Hz;≤75W
13)Battery Capcity:5200mAh
14)Battery Continuous working time:6~8Hrs
15)Data output:Built-in printer and R232 interface
Instrument Structure:
COM1:Reserved Port.
USB:USB disk interface. Insert the U disk to store(or export) the test data in the U disk.
COM2:PC serial port. Through this serial port, the instrument is connected to the upper computer and the operate it with the computer software.
AC:External 220V power supply input
POWER:Instrument power switch
IN:Oil sample input port
OUT:Oil sample export port
Printer:Print out test data.
Touch panel: used for touch control and display to realize the operation of the instrument.
Parameter |
LPC-P2 |
LPC-P3 |
LPC-P5 |
LPC-P50 |
LPC-P6 |
Dimensions |
310×305×135mm |
410×320×165mm |
275×220×107mm |
365×295×170mm |
420×326×182mm |
Weight |
7.5Kg |
8.5Kg |
2.5Kg |
5.5Kg |
8.5Kg |
Screen |
5.6 inch |
5.6 inch |
3.5 inch |
10.2 inch |
7 inch |
Power source |
Bidirectional piston pump |
Bidirectional piston pump |
Metering pump
|
Metering Pumps
|
Bidirectional piston pumps |
Battery |
Built-in 5200mAh |
Built-in 5200mAh |
External, optional |
Built-in 8000mAh, no battery indicator |
Built-in 5200mAh |
Repeatability |
≤2% |
≤2% |
≤5% |
≤5% |
≤2% |
Customized Channels |
16 channels
|
16 channels
|
No Customization
|
No Customization
|
64 channels
|
System Software
|
Multi-level account password login, editable test results
|
Multi-level account password login, editable test results
|
|
|
Multi-level account password login, editable test results
|
Moisture Viscosity Temperature Function |
Optional
|
Optional
|
Moisture temperature is standard. Viscosity is not optional
|
Moisture temperature is standard. Viscosity is not optional
|
Optional
|
Computer function
|
Connectable to computer
|
Connectable to computer
|
|
|
Connectable to computer
|
Packaging &Shipping:
Our product packaging has been proven over the long term and we usually have plywood boxes or cartons with trays. We will arrange the appropriate packaging according to the weight and size of the goods. Of course, you can also choose the packaging form.
Serial number |
name |
Specifications |
number |
1 |
Particle Counter |
|
1 |
2 |
Power line |
|
1 |
3 |
Drain tubing |
|
2 |
4 |
Safety tube |
3A |
1 |
5 |
Thermal printing paper |
|
2 |
6 |
Special tools |
|
1 |
7 |
Operation Manual |
|
1 |
Service |
Device Problem Handling |
Social media 24 hours online communication |
Mail Seamless Docking |
Video Conferencing |
Choose the Right Model Engineered for You!
Welcome to contact us talk about details if you are interested in Oil Particle Counter Particle Size Distribution Analyzer Particle Counters Suppliers !