• UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab
  • UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab
  • UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab
  • UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab
  • UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab
  • UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab

UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab

After-sales Service: Provide
Warranty: 1 Year
Weight: 1500 Kg
Power: 220 V AC, 60 Hz, 10 a
Control: PLC
Dimensions: 1, 165(W)X2, 165(D)X4, 350(H)mm
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Company Profile
  • Exhibition
  • Customer praise
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
GD-UL1685
Ambient Pressure Accuracy
+-200PA
Gas
95% Pure Technical Grade Propane (Provided by The
Packing
Plywood Case
Standard
UL1685 IEC 60332-3-10 En 50399
Display
256*128 LCD
Air Source Anemometer Range
8000L/Min
Wind Speed Adjustment
(5000±500)L/Min;
Enclosure
Stainless Steel
The Insulation Coefficient of The Box
0.7W/M2K
Thermocouple
K-Type Armored Thermocouple, 2mm Diameter
Distance Between Holes
3.2 mm
Transport Package
Wooden Case
Specification
ISO Certificate
Trademark
GOLD
Origin
Chongqing of China
HS Code
9031809090
Production Capacity
200PCS/Month

Product Description

Product Description

The Bunch Cable burning  Testing Machine is conformance to UL1685  and several standards,The vertical burning tester for wire and cable bundles is designed according to the relevant provisions of the UL1685 and GB18380.31 standards for wire and cable bundle burning tests. It also complies with IEC 60332-3-10, KS CIEC 60332-3-21~25 (Class A~D) standards. When a certain amount of gas is supplied to the box and ignited using a standard ignition source, this instrument can be used to test the vertical flame spread to the vertical cable and wire state. In addition, if the burner of this tester is adjusted by 20 degrees, it can meet the IEEE 383 (IEEE 1202) test standard. If a heat release instrument is attached, it can also measure dynamic values such as H.R.R
(heat release rate), S.P.R (smoke generation rate), etc.
The heat release test system is completely based on GBT31248-2014 and EN50399:2011 standards. It adds heat release test smoke pipes, air intake pipes and fans on the basis of GB18380.31 bundled combustion test furnace. It can test the combustion heat release performance of wires and cables.
UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab

Standards
·UL1685
·IEC 60332-3-10
·EN 50399
·GB/T 18380.31
·GBT31248-2014

Features of the box

1. The size of the stainless steel test box is 1,000±100(W)x2,000±100(D)x4,000±100(H)mm. The inner surface of the box is higher than the ground, and the back side is covered with thermal insulation materials.
2. Equipped with stainless steel ladders in accordance with the requirements of GB/T18380.31; one set of wide ladders 800mm and narrow ladders 500mm;
3. The steel ladder is made of stainless steel; corrosion-resistant; easy to clean;
4. In the lower part of the box, there is an air inlet of 800±20(W)x400±10(D) at a position 150±10mm from the front of the box.
5. An imported thermocouple K-type armored thermocouple with a diameter of 2mm is installed on the inside of the box;
6. An anemometer is installed on the top of the box to monitor the wind speed environment outside the combustion box;
7. A 300±30 (W) x1,000±100(D) exhaust port is opened on the top of the box to facilitate the exhaust of smoke during the test; the wind speed is adjustable at 10m/s;
8. Equipped with a standard electrical control cabinet;
9. Stainless steel exhaust pipes and related accessories;

UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab
Combustion system:

1. Burner: ribbon propane gas blowtorch, size 257mm x4.5mm, with 242 holes in total, arranged in three rows, 81, 80, and 81 holes respectively, the diameter of the hole is 1.35mm, and the distance between the holes is 3.2mm; 2. Imported American AGF blowtorch wick, 257mm long; 3. High-precision ball valve to control gas on and off; 4. Flow meter: imported air flow and gas flow meter and control valve; 100kpa, 20ºC conditions: air flow rate: (77.7±4.8) L/min; propane
(13.5±0.5)L/min; 5. Imported brand pressure gauge and pressure regulating valve; 6. Automatic ignition device; 7. Combustion angle: 20 degrees; 8. The air and gas flow rates in the burner must be supplemented with temperature and pressure, and many traditional systems ignore this effect. The gas and air compensation process can be automatically completed through computer programs. 9. Real-time monitoring of the temperature inside the box; equipped with high temperature alarm and automatic control of gas source shutoff;
10. The exhaust pipe is equipped with a heat release air intake port; it can be connected to an external combustion heat release analysis system


Control system:

1. PLC with large screen touch screen control system:
2. The system automatically ignites and automatically times;
3. The experimental data is automatically stored and can be freely queried; the test report can be freely printed;
4. 40 minutes, 1 hour timing reminder function;
5. Safety emergency cut-off device;
6. Standard parameters can be queried on the screen;

Equipment parameters:

1. The size of the test box is 1,000±100(W)x2,000±100(D)x4,000±100(H)mm. The anemometer accuracy is 0.1m/s;
2. The thermocouple is a K-type armored thermocouple with a diameter of 2mm;
3. The insulation coefficient of the box is 0.7W/m2K;
4. The air source anemometer range is 8000L/min; wind speed adjustment (50 00±500)L/min;
5. Gas: 95% pure technical grade propane (provided by the customer)
6. Gas control flow: 100kpa, 20ºC: air flow rate: (77.7±4.8)L/min; propane (13.5±0.5)L/min;

Equipment parameters:

1. Test box dimensions 1,000±100(W)x2,000±100(D)x4,000±100(H)mm Anemometer accuracy 0.1m/s;
2. Thermocouple is K-type armored thermocouple, 2mm diameter;
3. The insulation coefficient of the box is 0.7W/m2K;
4. Air source anemometer range 8000L/min; wind speed adjustment (5000±500)L/min;
5. Gas: technical grade propane with a purity of 95% (provided by the customer)
6. Gas control flow: 100kpa, at 20ºC: air flow rate: (77.7±4.8) L/min; Propane (13.5±0.5) L/min;
Optional; Smoke treatment device;

Specifications

Model Gold-GBT18380B
Dimensions 1,165(W)x2,165(D)x4,350(H)mm
Console dimensions 600(W)x750(D)x1,600(H)mm
Power supply AC 220V, 50/60hz, 15A
Weight 1,500kg
Exhaust 5,000L/min (inlet), 25m/min (outlet)

Heat release test system
Structural part:


1. The air supply adds a rectangular ventilation duct with a width of 300±10mm, a height of 80±5mm, a length of at least 800mm and an air box with a depth of 150±10mm;
2. The air inlet is equipped with a 2mm thick stainless steel grille with a grille aperture of 5mm and a center distance of 8mm;
3. Air intake volume 8000L/min;
4. The smoke exhaust system includes: smoke hood, smoke exhaust pipe, guide vane, fan, gas sampling system and analysis system. It is designed and manufactured completely according to standards.

Gas sampling system

1. Including annular sampler, suction pump, particulate filter, cold trap, exhaust valve, moisture filter and CO2 filter;
2. Three-stage filter; filtration accuracy 0.5um;
3. Refrigerated cold trap; compressor air conditioning refrigeration system; control temperature 0~5ºC;
4. Suction pump, flow: 33L/min, vacuum: 700mmHg, pressure: 2.5 bar;
5. Drying cylinder, filter moisture and impurities;
6. Flow controller; control suction flow;
7. The sampler has 12 small holes opposite to the air flow direction; built-in smoke filter; 685mm away from the smoke hood;

Measurement system

1. Oxygen concentration analysis: paramagnetic oxygen analyzer, O2 measurement range 0-25%, linear deviation <1%. The response time of the oxygen analyzer does not exceed 12s; the analyzer outputs the maximum resolution 100X10-6;
2. CO2 analysis: infrared CO2 analyzer CO2; measurement range: 0-2/10%, linear deviation: <±1%. The analyzer response time does not exceed 12s; the analyzer output maximum resolution is 100X10-6; 3. Smoke density analysis: Use the incandescent light system to measure smoke density. Color temperature 2900±100K; current fluctuation range ±0.5%; smoke density value linear output; and with time compensation function; 4. The lens focuses the light into a 20mm parallel beam; d/f<0.04; 5. Photoelectric detector imported from Japan; spectral distribution correspondence is consistent with CIE; chromaticity standard function accuracy ±5%; output linearity is Within 3% of the transmittance or within 1% of the absolute transmittance;
6. The response time of 90% of the system does not exceed 3s;
7. The imported Omega thermocouples are three K-type armored thermocouples with a diameter of 0.5mm; the temperature accuracy is 0.5ºC;
8. The pressure sensor imported from the United States has a range of 0~100pa; connected to a pressure sensor with an accuracy of ±2pad; the response time of 90% output of the pressure sensor is at most 1S;
9. Smoke exhaust capacity 0~0.65m/s;
10. Other general thermocouples 2mm K-type armored thermocouples;
11. Ambient pressure accuracy ±200Pa;
12. The system recording time is at least 3s;
13. The system time recording accuracy is 0.1s;


Computer control system

1. Standard control cabinet, computer + Labview intelligent control system;
Control parameter setting and display; test status and fault display and query.
.Collect and save various data; screen monitoring, real-time temperature curve, real-time CO2/O2 data curve display; historical curve and data query;
.Data USB export. Historical curve and data query and printing;
.Can independently control the machine to complete the test.
2. There are sound alarm and alarm accident display functions.
3. There is a USB/RS232 serial port on the control box, which can be connected to a desktop/laptop computer for operation and control.
4..Programmable controller (PLC) control system:
.Automatic ignition, ignition failure detection protection.
.Automatic control and display of propane gas flow.
·PLC+frequency converter implements automatic control and display of exhaust gas flow.
.Automatic measurement and calculation of material combustion: heat release rate (H.R.R), smoke growth index (SPR), oxygen consumption (O2), CO2 generation.

Specifications

Model GOLD-EN50399
Dimensions 1,165(W)x2,165(D)x4,350(H)mm
Console dimensions 600(W)x750(D)x1,600(H)mm
Power supply AC 220V, 50/60hz, 15A
Weight 1,500kg
Exhaust 5,000L/min (inlet), 25 sqm/min (outlet)
 

Company Profile

UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab

UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable LabUL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab
 

Exhibition

 

UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab

Customer praise

 

UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab
 

Packaging & Shipping

UL 1685 IEC 60332 Burning Bunch Cables Test Machine for The Cable Lab


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.