Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support
Warranty: 1year
Still deciding? Get samples of US$ 5500/Set
Request Sample
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
  • Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
  • Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
  • Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
  • Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
  • Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Basic Functions
  • Main Technical Features
  • Working method
  • Detailed Photos
  • Related products
  • Contact us
Overview

Basic Info.

Model NO.
GD-H1706
Accuracy
± 1.5%
Maximum Measurement Range
≤3D
Density Meter Type
Viscometer
Viscometer Type
Apparent Dynamic Viscometer
Density Meter Principle
Apparent Dynamic Viscometer
Test Density
Apparent Dynamic Viscometer
Viscometer Reproducibility
Apparent Dynamic Viscometer
Viscometer Rotor Number
1
Viscometer Rotor Speed
60r/min
Viscometer Rotor Specifications
1 Size
Product Name
Apparent Dynamic Viscometer
Working Temperature of Bath
Room Temperature~150 Celsius
Temperature Control Accuracy
0.1 Celsius
Timing Range
0~999.9s
Timing Accuracy
0.1s
Working Unit
1 Unit
Control Method
Touch LCD Screen
Applicable Standards
Sh/T0703, ASTM D5481
Working Power Supply
AC220V, 50/60Hz
Total Power
500W
Transport Package
Wooden Case for Apparent Dynamic Viscometer
Specification
400*430*850mm
Trademark
GOLD
Origin
China
HS Code
9031809090
Production Capacity
100 Sets/ Month

Product Description

 Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil

Product Description

1.GD-H1706 Hihg-Temperature and High-Shear Rate Apparent Viscosity Tester (HTHS) conforms to ASTM D5481 Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer, it covers the laboratory determination of hihg-temperature high-shear (HTHS) viscosity of engine oil at a temperature of 150ºC using a multicell capillary viscometer containing pressure, temperature, and timing instrumentation.
2.The shear rate for this test method corresponds to an apparent shear rate at the wall of 1.4 million reciprocal seconds (1.4 3 106s-1).This shear rate has been found to decrease the discrepancy between this test method and other high temperature hihg-shear test methods used for engine oil specifications.
 
3.After strict calibration, the viscometer cell has good repeatability and reproducibility, meeting the accuracy requirements of ASTM D5481 and SH/T 0703 standards.
Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil

Product Parameters

Model No. GD-H1706
Applicable standards SH/T0703, ASTM D5481
Heating method By electrical bar
Test temperature Room temperature ~ 150ºC
Temperature control accuracy ±0.1ºC
Working unit 1 unit
Control method Touch LCD screen
Results calculation Windows high temperature high shear viscosity calculation software
Screen display content Test pressure, test time, sample constant temperature time
Working power supply AC220V, 50/60HZ
Total power 500W
Dimension 400*430*850mm
Net weight 35KG

Basic Functions

1)Power
After the instrument is powered on, the exhaust fan starts to work, and the touch screen starts to display.
2)Heating
The heating part of the instrument is a metal bath made of aluminum alloy, which is heated by a heating rod, and the viscometer cell is installed in it.It takes about 30 minutes to heat the temperature from room temperature to 150 ºC, so it is necessary to turn on the instrument for heating before starting the experiment.
3)Pressure adjustment
After the nitrogen source is connected with the instrument, the instrument can be pressurized. There is a gas cylinder inside the instrument to provide pressure for the instrument during the experiment, and the external nitrogen source only supplies gas to the gas cylinder.
4)Start/stop experiment
In the normal experiment process, click [start / stop experiment] to start the experiment. The experiment is carried out automatically. Under normal circumstances, the experiment will stop automatically, and there is no need to end it manually.
5)Timing
Clicking the constant temperature timer will start a 15min timer to indicate the heating time.
6)Setting
Click [Set] button to switch to the setting page. Click the input box, the user can enter the operator and sample ID on the right side of the page, in order to distinguish in the result query.
7)Results query
This instrument can record the results of the experiments made by users, and the number of records is more than 30,000.

 

Main Technical Features

1.This instrument has been widely used by many customers in China and and outside China.
2.The accessories can be exchanged with imported equipment.
3.Equipped with a special high shear viscosity calculation software.
4.The instrument allows 24 hours a day and running continuously for 365 days.
5.No solvent cleaning is required, only a small amount of fresh sample is required for rinsing.
6.The glass capillary tube meets the standard requirements, with a diameter of 0.15mm and a length of 16mm.
7.For the purpose of research, users can set different shear rate and test temperature.
8.Made of all aluminum materials.
9.Touch LCD control, can be operated directly on the LCD screen.
10.The software automatically recommends the test pressure, and the test results can be generated by Excel report.
11.We're patented for the oil shear viscometer, the patent No. is ZL201821712254.6

Working method

A complete test procedure includes the following four operating steps: sample rinse, sample infiltration, set volume and test sample.If you want to know more information,Don't hesitation, welcome your inquiry!Price can be negotiated !We can provide the following quality assurance:The company shall guarantee the quality of the instrument for one year from the date of purchase in case of material or workmanship problems. Within the specified warranty period, if the failure of the instrument is not caused by abuse and needs to be repaired, we will repair it free of charge.Our company will determine whether the specific fault is due to its own fault or the abuse of customers. Instruments outside the quality warranty period will be charged for repair costs as appropriate.

Detailed Photos

Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil

 

Related products

Other Popular asphalt testing instrument:

Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil
Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil

Contact us

Welcome to contact us talk about details if you are interested in Apparent Dynamic Viscometer by High Temperature High Shear ASTM D5481 for Lubricating Oil.If you want to know more information,Don't hesitation, welcome your inquiry!Price can be negotiated!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier