Digital Display Transformer Dielectric Loss Tester Tan Delta Test Set

After-sales Service: Lifetime Technical Support
Warranty: 1 Year for Transformer Tan Delta Tester
Type: Transformer Tan Delta Tester
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GDMZ
Display
Digital
Control
Manual Control
Weight
28kg
Power Source
AC220V
Product Name
Transformer Tan Delta Tester
High Voltage Output
0.5~10kv
Accuracy 1
Tg: ± (Reading *1.5% +0.06%);
Measuring Range
0.001% <Tg <100%
Accuracy 2
Cx: ± (Reading * 1.5% +5 PF)
Harmonic Adaptation
≤ 3%
Power Supply
AC 220V ± 10% 50/60 ± 1Hz
High Voltage Output 1
Increasing by 500V for Each Level, a Total of 20 L
Transport Package
Plywood Case
Specification
465*350*360mm
Trademark
GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description


Digital Display Transformer Dielectric Loss Tester Tan Delta Test Set
 
Digital Display Transformer Dielectric Loss Tester Tan Delta Test Set
Digital Display Transformer Dielectric Loss Tester Tan Delta Test Set

Tan Delta Test | Loss Angle Test | Dissipation Factor Test

Digital Display Transformer Dielectric Loss Tester Tan Delta Test Set
A pure insulator when is connected across line and earth, it behaves as a capacitor. In an ideal insulator, as the insulating material which acts as dielectric too, is 100 % pure, the electric current passing through the insulator, only have capacitive component. There is no resistive component of the current, flowing from line to earth through insulator as in ideal insulating material, there is zero percent impurity.

In a pure capacitor, the capacitive electric current leads the applied voltage by 90°.

In practice, the insulator cannot be made 100% pure. Also due to the aging of insulators, the impurities like dirt and moisture enter into it. These impurities provide the conductive path to the current. Consequently, an electric leakage current flowing from line to earth through the insulator has a resistive component.


Hence, it is needless to say that, for good insulator, this resistive component of electric leakage current is quite low. In another way, the healthiness of an electrical insulator can be determined by the ratio of the resistive component to the capacitive component. For good insulator, this ratio would be quite low. This ratio is commonly known as tanδ or tan delta. Sometimes it is also referred to as dissipation factor.

Method of Tan Delta Testing

The cable, winding, current transformer, potential transformer, transformer bushing, on which tan delta test or dissipation factor test to be conducted, is first isolated from the system. A very low-frequency test voltage is applied across the equipment whose insulation to be tested.
First, the normal voltage is applied. If the value of tan delta appears good enough, the applied voltage is raised to 1.5 to 2 times of normal voltage, of the equipment. The tan delta controller unit takes measurement of tan delta values. A loss angle analyzer is connected with tan delta measuring unit to compare the tan delta values at normal voltage and higher voltages and analyze the results.During the test, it is essential to apply test voltage at a very low frequency.

 
Power supply AC 220V ± 10% 
High voltage(HV) output 0.5~10KV  (12KV can be customized)
Increasing by 500V for each level, a total of 20 levels, capacity: 1500VA
Measuring range 0.001% 100%;
Internal High Pressure:3PF~60000PF/10KV, 60PF~1µF/0.5KV.
External High Pressure:3PF~1.5µF/10KV,60PF~30µF/0.5KV
Measuring method 1) Single frequency:45(45Hz measuring),50(50Hz measuring), 55(55Hz measuring),60(60Hz measuring),65(65Hz measuring)
2) Different frequency:50D(45Hz/55Hz measure each time); 60D(55Hz/65Hz measure each time); Automatic frequency conversion.
Accuracy tgδ: ± (reading *1.5% +0.06%)
Cx: ± (reading * 1.5% +5 PF)
Resolution tgδ: 0.001%   Cx: 0.001pF
CVT Variable ratio test Variation ratio measurement accuracy: ± reading *1%
The range of the measurement: 10~99999
Phase measurement accuracy: ±0.1°
Phase measurement range: 0~359.9°
Harmonic adaptation ≤ 3%
Application condition -15 ºC-50 ºC Relative humidity <80%
Size and weight 465*350*360mm,28kg

Accessory
Digital Display Transformer Dielectric Loss Tester Tan Delta Test Set

Test Results