Customization: | Available |
---|---|
After-sales Service: | Technical Support,Online Service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Name |
Needle flame tester |
standard |
IEC 60695 |
Power |
220V / AC, 50Hz |
Temperature range |
0--1000 ºC |
1. Needle burner: stainless steel, inner diameter of ¢ 0.5 ± 0.1mm, an outer diameter of not more than ¢ 0.9mm, length 35mm more
needles, no air access.
2. The burner angle: vertical (when adjusting and measuring the flame height) or inclined 45 ° (the test).
3. Combustion gases: 95% butane gas or propane gas.
4. Ignited bedding layer: white pine plank (thickness 10mm), surface covering 12 ~ 30g / m2 standard tissue paper layer is applied
at lower flame from 200mm ± 5mm.
5. Temperature range: 0--1000 ºC.
6. The flame temperature requirements: from 100 ± 2 ºC ~ 700 ºC ± 3 ºC, should be completed within 23.5 ± 1.0s.
7. The flame height: 12mm ± 1mm.
8. The burning time: 0s ~ 999.9s adjustable, generally set at 30s.
9. Holding burning time: 0s ~ 999.9s, automatic recording, manual pause.
10. Test Space: ≥0.5m3, black background, (can be customized cubic 0.75 m3 or 1 m3 according to customer requirements).
11. Temperature sensor: K-type insulation-sheathed thermocouple (Φ0.5mm).
12. Test program automatic control, independent ventilation system.
13. Dimensions:1120 (L)* 520(W) * 1250(H)mm, exhaust Φ100mm.
14. Test Power: 220V / AC, 50Hz..
Test method selection
What is a needle flame test?
The full name of IEC 60695-2-2 is Fire hazard testing Part 2: Test methods - Section 2 Needle-flame test. It was prepared by IEC technical committee 89: Fire hazard testing. The following is the related introduction of IEC 60695-2-2 Scope. This section of IEC 60695-2-2 specifies a needle-flame test to simulate effect of small flames which may result from fault conditions within equipment, in order to assess by a simulation technique the fire hazard. It is applicable to electrotechnical equipment, its sub-assemblies and components and to solid electrical insulating material or other combustible materials.
What is flame retardant test methods?
In the case of horizontal needle flame test HB classification, the sample size is required to be 125mm in length, 13mm in width, and no more than 13mm in thickness. The sample is placed horizontally, the sample clamp is clamped to one end of the sample, and the ignition device is at a 45 degree angle to keep the flame position unchanged. Apply 30±1S to the other end of the sample holder, and place a metal mesh and a freely movable fixed frame horizontally under the sample holder, so that when the sample burns, the free end and the metal mesh are kept 10mm.
Packing Details |
Wooden case for IEC 60695-2-2 needle flame combustibility apparatus |
Ports |
Shanghai, Guangzhou, Shenzhen, etc |
Lead Time |
30 Business Days |