Room Corner Tester, ISO 9705, ISO 13754, Ks F ISO 13784, ASTM E 1537, Nfpa 265, Nfpa 286

Warranty: 1 Year
Oversea Training: Available
Transport Package: Plywood Case
Trademark: Gold
Origin: China
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-9705
HS Code
9031809090
Production Capacity
5 Sets/Month

Product Description

Introduction
(RCT), as ISO's the evaluation of fire-resistance performance of building materials, measures heat release rate (H.R.R), smoke generation rage, oxygen consumption, CO, CO2 production and so on. 
As basis of ISO 9705(Fire tests - Full scale room test for surface products), RCT is the test that reproduces local fire conditions by flame combustion in the small room of building structure and measures fire movement and combustion diffusion in the building structure. 
ISO 9705 states a test method to progress fire generation from the corner of room and the purpose of this test method is to assess what the surface product supplies to the fire growth using standard ignition source. 
The standard ignition source is stated but another option is also possible. 
But we must be careful of what the form, position and heat output influence to the fire growth. 
This method is suitable to the product - materials like thermoplastic resin, insulated circuit, joints and laboratory having irregular surface - which is impossible to experiment in the small laboratory. 
The object of this method does not assess fire resistance of product. So Room Corner Tester (RCT) on ISO 9705 assesses the Heat Release Rate about initial step of fire from ignition to maximum flash-over. The maximum Heat Release Rate can be measured up to 3MW.

Standard
• ISO 9705 : Fire tests - Full scale room test for surface products 
• ISO 13784-1: Reaction to fire tests for sandwich panel building systems 
• ASTM E 1537:  Standard Test Method for Fire Testing of Upholstered Furniture 
• ASTM E 603:  Standard Guide for Room Fire Experiments 
• prEN 14390: Fire Test - Full Scale Room Test for Surface Products 
• NFPA 265: Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls 
• NFPA 286: Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth

Specification
Measuring Section. 
- Bi-Directional Probes & DPT (Differential Pressure Transducer) for measuring flow rate in duct 
- Thermocouples for measuring temperature in duct 
- Sampling Port & Analyzer (O2, CO2, CO) for collecting and analyzing generated gases 
- Laser used to measure the amount of smoke 
Rapid cooling system (Cold Trap) used to remove moisture for analyzing pure gas 
Pressure (DPT) Line for measuring flow rate and Gas Sampling for gas collection. 
Filtering System for delivering reliable gases with no impurities into analyzer 
Module for data collection (Data Logger, DAQ System) 
PC for auto control and data monitoring 
MFC(Mass Flow Controller) for automatically controlling flow of propane gas. 
Auto Valve System for opening/closing propane gas. 
Ignition System for auto ignition 

Specification

Size

Test Room (mm) 
3,600 (w) × 2,400 (d) × 2,400 (h) 

Hood  (mm) 
3000 (w) × 3000 (d) × 2950 (h) 

Sandbox Burner (mm) 
170 (w) × 170 (d) × 145 (h)

Power

220V AC, 60Hz, 10A

Exhaust

3.5 m2/s

Utilities

Propane Gas Valve System,
Ignition System

 

Features
Hood Skirt: Hood for collection of flue gases and prevention of flue gases of overflow. 
Strainer for securing stable flow. 
Suction pump for drawing gases generated in duct to the Control Lab

Test Result
Heat Release Rate 
Smoke Product Rate 
Consumption and yield measurement of O, CO and CO 
Analysis of other toxic gases (Others Toxic Gas By FT-IR) 
Measurement of change in temperature of entrance 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters