Customization: | Available |
---|---|
After-sales Service: | Online and Offline Service |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. This Cleveland Open Cup Apparatus is a kind of fully-automatic instrument which can do determination for both flash point and fire point. It adopts LCD screen to display and full English man-machine interface. It can preset expected flash point temperature, sample mark number, barometric pressure and other parameters.It has menu prompt and input guide.
2. It adopts simulation tracking to display the function curve of temperature rising and test time. It has the functions of English mis-operation prompt,test date,test time and other parameters.
3. It can store 10 screens,120groups data.
4. Automatically calibrate the effect of atmospheric pressure to test and calculate the corrected value.
5. Differential coefficient detection.Automatically correct the system deviation.
6. Automatically open the lid,detect the flash point and print test data.The test arm automatically rise up and lower down
1 | Power supply | AC(220±10%)V, 50Hz |
2 | Temperature measurement | Range:room temperature~400ºC |
Repeatability:≤8ºC | ||
Reproducibility:≤17ºC | ||
Accuracy:0.1ºC | ||
3 | Heating rate | Correspond with GB/T3536 and ASTM D92 |
4 | Igniting mode | Electric ignition |
Gas flame diameter: 3.2mm~4.8mm | ||
5 | Ambient temperature | (10~40)ºC |
6 | Relative humidity | ≤80% |
7 | Maximum power consumption | 500W |
8 | Dimension | 520mm*380mm*310mm |
1. If the oil sample is lubricating oil, the expected flash point of which is 180 ºC, you can preset temperature to 180 ºC. Then the instrument will apply flame to the sample at a temperature 28 ºC lower than the preset temperature (152 ºC). If the expected flash point of oil sample is unknown, please set critical value of flash point (such as 180ºC), then preset temperature from low to high.
2. Please preset sample ID for recording. It can be numbered in the range of 1~999.
3.According to different altitude, test results have relative error. The instrument can modify the influence of barometric pressure on test value and calculate the correction value automatically through inputting local barometric pressure
(refer to GB/T3536 standard for barometric pressure correction value), modify the value as the table below:
Barometric | Correction value, ºC | ||
K Pa | M ba | Mm Hg | |
95.3~88.7 | 953~887 | 715~665 | 2 |
88.6~81.3 | 886~813 | 664~610 | 4 |
81.2~73.3 | 812~733 | 609~550 | 6 |
Except for the ASTM D92 Cleveland Open Cup Apparatus, we can also provide ASTM D93 Pensky Martens Closed Cup Apparatus
If you are interested in our ASTM D 92 Cleveland Open Cup Apparatus for Petroleum Products, Lube Oil and Gear Oil product or have any questions, please feel free to contact us.