• Imo Fire Testing Instrument Flame Spread Tester
  • Imo Fire Testing Instrument Flame Spread Tester
  • Imo Fire Testing Instrument Flame Spread Tester
  • Imo Fire Testing Instrument Flame Spread Tester
  • Imo Fire Testing Instrument Flame Spread Tester
  • Imo Fire Testing Instrument Flame Spread Tester

Imo Fire Testing Instrument Flame Spread Tester

After-sales Service: All Life Technical Supports
Warranty: 12 Months
Item Name: ISO 5658-2 Imo Fire Testing Instrument
H. S. Code: 9031809090
Overseas Training: Provide
Application: Building Materials, Rail, Imo
Customization:
Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
GD-ISO5658
Power
110V AC 60Hz / 230V AC 50Hz, 10A
Weight
About 250kg
Size
1650 mm (W) *810 mm (H) *1985 mm(L)
Material
Stainless Steel
Usage
Fire Testing Instrument
Exhaust
0.01 M3/S
Utilities
Propane Gas, Methane Gas, Acetylene Gas, Compresse
Standard
ISO 5658-2; ASTM E 1317
Function
Fire Testing Instrument
Manual
Provide
Transport Package
Packed in Standard Export Wooden Case
Specification
1m3
Trademark
GOLD
Origin
Chongqing China(Mainland)
HS Code
9031809090
Production Capacity
5 Units Per Month

Product Description

 IMO Fire Testing Instrument Flame Spread Tester 

Imo Fire Testing Instrument Flame Spread Tester

Introduction:

ISO 5658-2 IMO Fire Testing Instrument Flame Spread Tester is used to evaluate combustion characteristics of building materials and ship materials and measures the spread rate of flame, flame for ignition by distances, CFE (Critical Flux at Extinguishment), and total heat release. This test method originated from ISO 5658-2 (Reaction to fire tests-Spread of flame- Part 2 Lateral spread on building products in vertical configuration) and measures combustion characteristics of the vertical specimen (155 mmX800 mm). 

The specimen is exposed to the reasonable radiant heat field and is measured by a thermocouple for exhaust gas calibrated through the progress of combustion as a unit of mV. 

IMO records the spread rate of flame after this records ignition and extinguishment time of flame for each distance of specimens. And the other test results are Heat for ignition (MJ/m2), Heat for sustained burning (MJ/m2), Critical flux at extinguishment (kW/m2), Average heat for sustained burning (MJ/m2), Total heat release (kW) and so on.


Standard:

  • ISO 5658-2: Reaction to fire tests -Spread of flame - Part 2 Lateral spread on building products in vertical configuration; 
  • IMO Resolution A. 653(16): Recommendation on fire test procedures for flammability of bulkhead, ceiling, and deck finish materials; 
  • ASTM E 1317: Standard test method for flammability of marine surface finishes;


Application:

  • Building Materials
  • Rail
  • IMO


Detailed Image:

Imo Fire Testing Instrument Flame Spread Tester

Features:

  1. All control systems are explosion-proof. 
  2. Air Cylinder type of Pilot Flame Burner allows the flame impingement test method based on IMO to be automatically performed. 
  3. Double grid to see the spread of flame length and enlarged Restrict View Mirror for easy observation. 
  4. DAQ Program for applying a spread of flame length and combustion characteristics to image storage. 
  5. 19" Analysis Rack for measuring spread rate of flame, critical flux, and heat release rate. 
  6. IMO Program of controlling Air Blower to facilitate change in the amount of combustion-heat in Radiant Panel Calibration (for measuring heat release rate by each section of the radiant panel. 
  7. Program for blocking gas supply in failure of ignition in the radiant panel, which Flame Relay System detects.
  8. Rail for easily measuring heat flux of radiant panel at an interval of 50mm. 
  9. IMO Program to facilitate all calibrations and tests as well as to print results by standards (IMO, ISO). 
  10. Radiant panel temperature controller: Equipment to prevent flame back toward the back side of the Radiant panel, check the internal temperature of the radiant panel, and automatically block gas sol. v/v in case of flame back-flow. 
  11. MFC (Mass Flow Controller) to easily measure the heat amount of methane gas in measuring critical heat flux. 
  12. Explosion-proof options of all control systems for safety in combustion in the radiant panel as well as the Check-Valve and its Gas shut-off valve (Solenoid Valve) to prevent back-flow in the gas line. 


Test Result:

• Heat for sustained burning (MJ/m2) 

- It is gained by multiplying time, which ranges from the initial exposure of the test object to the arrival of the flame-tip in each point, by radiant heat flow penetrated against a nonflammable calibration panel in the same point.

• Average heat for sustained burning (MJ/m2) 

- It is an average of characteristic values measured in individual positions by continuous sustained heat. The characteristic value is measured in continuous position at an interval of 50 mm from the initial 1500mm to the final position or 400 mm, whichever is lower.

• Heat for ignition (MJ/m2) 

- It is gained by multiplying time, which ranges from the initial exposure of the test object to the arrival of the flame-tip at a point of 150 mm, by the heat flow of this point. (However, heat flow is gained by pre-calibration of test equipment.)

• Critical flux at extinguishment (kW/m2) 

- It means heat flux in the location where flame spreads to the farthest distance from the center line of the combusting test object. The heat flow is gained by performing a calibration test of the tester using calibration panels.

• Total heat release (MJ) 

- It means total heat release during the test period.

• Peak heat release rate (kW) 

- It means peak heat release rate during the test period. 


Specification:

Product name ISO 5658-2 IMO Fire Testing Instrument Flame Spread Tester 
Electrical 110V AC 60Hz / 230V AC 50Hz, 10A
Ambient Temperature Operating 10°C to 35°C
Gas Supplies Propane Gas, Methane Gas, Compressed Air
Optional Gas  Acetylene Gas
Exhaust 0.01 m3/s
Weight about 250kg
Size: 1650 mm (W) x 810 mm (H) x 1985 mm

FAQ 

Q: How long is the delivery time?

A: 5-50 days after we receive your payment or order confirmation.

Q: What is the payment terms?
A: T/T, L/C, Western Union, etc.

Q: What are the delivery terms?
A: FOB, EXW, CNF, CIF, etc.

Q: How to make sure the equipment is by related standards?
A: All the devices are designed and made strictly according to International standards, you can also consult our client about their use experience.

Q: What is the warranty for the ISO 5658-2 Imo Fire Testing Instrument Flame Spread Tester Flammability Testing Equipment?
A: 12 Months. We can also provide you with lifelong technical support.

Q: What after-sales service can be provided by Gold?
A: The after-sales service of Gold is divided into two parts: technical support and maintenance.

Q: What about the technical support and maintenance?
A: Sometimes users who are unfamiliar or first time use may meet some problems when they operate the equipment, you can send us emails or calls with detailed information. We will provide user solutions or operation videos to you. With so many years of experience, our instruments work quite well. If there is any part broken down during the warranty period, we would like to provide spare parts for free.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
100800000 RMB
Plant Area
>2000 square meters