Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer

Product Details
Customization: Available
After-sales Service: Lifetime Technical Support, Online Service
Warranty: 1 Year for CT PT Parameters Analyzer
Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
100800000 RMB
Plant Area
>2000 square meters
  • Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
  • Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
  • Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
  • Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
  • Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
  • Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
Find Similar Products

Basic Info.

Model NO.
GDVA-405 CT PT Analyzer
Accuracy Grade
0.02%
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Embedded Computer
Weight
15kg
Power Source
AC220V
Applications
CT PT Paramteres Analysis
Test Standards
IEC60044-1/2/5/6, IEC61869, C57.13
Suitable for
Testing CT/PT (220V~500kv, Capacity ≥2.5va)
Accuracy
0.02%(Typical), 0.1% (Guaranteed)
Voltage Output
0.1-180V (AC)
Current Output
0.001-5A(RMS)
Power Output
500va
Max. Knee Voltage Measurement
60kv
Power Supply
AC220V±10%, 50/60Hz(Support Customize)
Transport Package
Plywood Case
Specification
49*36*19cm
Trademark
CHONGQING GOLD
Origin
Chongqing, China
HS Code
9030849000
Production Capacity
500 Pieces/Month

Product Description

Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
GDVA-405 Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer is designed for automatic testing of protection and metering CT/PT (220V~500KV,capacity ≥2.5VA), suitable for laboratory and field testing. This source generates AC of 0-180V and 0.001-5A current to sample CT. The accuracy is 0.02%(Typical),0.1%(Guarantee).
 

Range of Measurements

 

Test items for Current Transformer(CT) Test items for Potential Transformer(PT)

Turn ratio detection

Ratio and angle error check

Polarity test

Excitation characteristic test

Secondary winding resistance measurement and secondary burden measurement

5% and 10% error curve measurement

Transient characteristics analysis

Automatic nameplate inference

Knee point voltage/current

Accuracy Limit Factor (ALF)

Instrument security factor (FS)

Secondary time constant (Ts)

Remanence coefficient (Kr)

Accuracy

Saturation and desaturation inductance

Knee point electromotive force

Limit electromotive force

Area factor

Iron core analysis and core hysteresis loop measurement

Turn ratio measurement

Ratio and angle error check

Polarity test

Excitation characteristic test

Primary winding resistance test

Secondary winding resistance test

Se


Specifications

 

Item Name GDVA-405 Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
Test standards IEC60044-1, IEC60044-6, IEC61869, IEC60044-2, IEC60044-5, C57.13
Power supply  AC220V±10%, 50/60Hz±10%(Support customize)
Voltage output  0.1-180V (AC)
Current output  0.001-5A(RMS)
Power output  500VA
Max.  knee voltage measurement  60KV
Current measurement
 
 
  Range 0-10A (automatically change  range in 0.1/0.4/2/10A)
  Error  <±0.1%+0.01%FS

 

Voltage measurement
 
 Range 0-200V (automatically change range in 1V/10V/70V/200V)
 Error < ±0.1%+0.01%FS
Turns ratio measurement Range
  
1~35000
1~2000, error<0.05%
2000~5000,error<0.1%
5000~35000,error<0.2%
Phase measurement   error  ±2min
resolution  0.01min
Winding resistance measurement
    
   
Range 0-8kΩ (automatically change range in2ohm/20ohm/80ohm/800ohm/8kohm)
Error  < 0.2%RDG+0.02%FS
Maximum resolution :  0.1mΩ
Temperature measurement -50-100 Celsius degree; error<3 Celsius degree
CT Secondary burden Range 0-160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)
Error  <0.2%RDG+0.02%FS
Maximum resolution : 0.001ohm
   
  
PT Secondary burden
 
Range 0-80kohm (automatically change range in 800ohm/8kohm/80kohm)
Error <0.2%RDG+0.02%FS
Maximum resolution : 0.1ohm
   
PT ratio measurement
Range

1-35000,

1-10000 error<0.1%, 

10000-35000 error<0.2%

PT ratio error measurement :Typical error<0.05%,  Maximum Error<0.1%
PT phase angle measurement maximum error < 3min
Make evaluation for test results according to selected standards
Make word report for test result
Make word reports one time for multi-group test records on the PC
Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test
Compare excitation curves with saved excitation curves in the same window
Memory capacity  >1000 groups test results
Working condition temperature  -10ºC-50ºC; moist ≤90%
Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer

Work Site

Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer
Power Frequency Current Transformer Excitation Curve Analysis CT PT Parameters AnalyzerPower Frequency Current Transformer Excitation Curve Analysis CT PT Parameters AnalyzerPower Frequency Current Transformer Excitation Curve Analysis CT PT Parameters AnalyzerPower Frequency Current Transformer Excitation Curve Analysis CT PT Parameters Analyzer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier